1.5SMC6.8CA

Manufacturer: VISHAY

BI-DIRECTIONAL GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR 1500 WATTS, 6.8 THRU 200 VOLTS

Partnumber Manufacturer Quantity Availability
1.5SMC6.8CA,15SMC68CA VISHAY 87000 In Stock

Description and Introduction

BI-DIRECTIONAL GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR 1500 WATTS, 6.8 THRU 200 VOLTS The part number 15SMC68CA is a Transient Voltage Suppressor (TVS) diode manufactured by Vishay. Here are the key specifications:

- **Voltage - Reverse Standoff (Typ):** 68V
- **Voltage - Breakdown (Min):** 75.4V
- **Voltage - Clamping (Max) @ Ipp:** 110V
- **Current - Peak Pulse (10/1000µs):** 15A
- **Power - Peak Pulse:** 1500W
- **Power Line Protection:** No
- **Unidirectional Channels:** 1
- **Operating Temperature:** -55°C to 150°C
- **Package / Case:** DO-214AB, SMC
- **Mounting Type:** Surface Mount
- **Supplier Device Package:** SMC

This TVS diode is designed to protect sensitive electronics from voltage transients and surges.

Application Scenarios & Design Considerations

BI-DIRECTIONAL GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR 1500 WATTS, 6.8 THRU 200 VOLTS# Technical Documentation: 15SMC68CA Transient Voltage Suppressor (TVS)

 Manufacturer : VISHAY  
 Component Type : 15kW Transient Voltage Suppressor Diode  
 Document Version : 1.0  
 Date : October 2023

## 1. Application Scenarios

### Typical Use Cases
The 15SMC68CA is a 15kW surface-mount transient voltage suppressor designed for high-power surge protection in demanding applications. Typical deployment scenarios include:

 Primary Protection Applications: 
- Direct lightning surge protection in telecommunications equipment
- Industrial motor drive systems requiring robust overvoltage protection
- Power supply input stages in harsh electrical environments
- Automotive electronic control units (ECUs) for load dump protection

 Critical Infrastructure Protection: 
- Telecom base station power and signal lines
- Industrial PLC systems exposed to voltage transients
- Renewable energy systems (solar/wind inverter protection)
- Medical equipment power input protection

### Industry Applications

 Telecommunications: 
- Protects sensitive RF equipment from induced lightning surges
- Base station power and data line protection
- DSL/POTS line interface circuits
- Meets GR-1089 and ITU-T K.20/K.21 surge standards

 Industrial Automation: 
- PLC I/O module protection (24V/48V systems)
- Motor drive input stage surge suppression
- Process control instrumentation
- Compliant with IEC 61000-4-5 surge requirements

 Automotive Electronics: 
- Load dump protection (ISO 7637-2 compliant)
- ECU power input protection
- 12V/24V automotive bus systems
- Electric vehicle charging systems

 Power Systems: 
- Switch-mode power supply input protection
- UPS system surge suppression
- Renewable energy converter protection

### Practical Advantages and Limitations

 Advantages: 
-  High Surge Capability : 15kW peak pulse power (8/20μs waveform)
-  Low Clamping Ratio : Excellent voltage limiting characteristics
-  Fast Response Time : Typically <1.0ps response to transients
-  Surface Mount Package : SMC (DO-214AB) package for automated assembly
-  High Temperature Operation : -65°C to +150°C operating range
-  AEC-Q101 Qualified : Suitable for automotive applications

 Limitations: 
-  Package Size : SMC package requires adequate PCB space
-  Thermal Management : Requires proper heat sinking for repeated surges
-  Voltage Margin : Requires careful selection to avoid normal operation near breakdown
-  Cost Consideration : Higher cost compared to lower power TVS devices

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Inadequate Voltage Margin 
-  Problem : Selecting VRWM too close to operating voltage
-  Solution : Maintain 10-20% margin above maximum operating voltage

 Pitfall 2: Poor Thermal Management 
-  Problem : Repeated surges causing thermal runaway
-  Solution : Implement adequate copper pour for heat dissipation

 Pitfall 3: Incorrect Placement 
-  Problem : TVS located too far from protected circuit
-  Solution : Place within 1-2 cm of protection point with minimal trace inductance

 Pitfall 4: Grounding Issues 
-  Problem : High-impedance ground connection reducing effectiveness
-  Solution : Use low-inductance ground path with multiple vias

### Compatibility Issues with Other Components

 With Microcontrollers/Digital ICs: 
- Ensure VCLAMP is below absolute maximum ratings of protected devices
- Consider adding series resistance for current limiting

 With Power Supplies: 
- Coordinate with input filters to avoid oscillation
- Consider inrush current compatibility

 With Other Protection Devices: 
- May be used in coordination with gas discharge tubes (