1500 Watt peak power transient voltage suppressor. Reverse stand-off voltage VRWM = 94.00 V. Test current IT = 1 mA.# Technical Documentation: 15KE110CA TVS Diode
 Manufacturer : GI (General Instrument)
## 1. Application Scenarios
### Typical Use Cases
The 15KE110CA is a bidirectional Transient Voltage Suppression (TVS) diode designed for robust overvoltage protection in electronic circuits. Typical applications include:
-  Power Line Protection : Safeguarding DC power supplies from voltage transients and surges
-  Data Line Protection : Protecting communication interfaces (RS-232, RS-485, Ethernet) from ESD and lightning-induced surges
-  Automotive Systems : Load dump protection in automotive electronics (12V/24V systems)
-  Industrial Control Systems : Protecting PLCs, sensors, and control units from switching transients
### Industry Applications
-  Telecommunications : Base station equipment, network switches, and communication interfaces
-  Automotive Electronics : ECU protection, infotainment systems, and power distribution modules
-  Consumer Electronics : Power adapters, set-top boxes, and home automation systems
-  Industrial Automation : Motor drives, power supplies, and measurement equipment
-  Renewable Energy : Solar inverters and wind power systems
### Practical Advantages and Limitations
 Advantages: 
-  High Surge Capability : Withstands 15kW peak pulse power (10/1000μs waveform)
-  Fast Response Time : Typically <1.0ps reaction to transient events
-  Bidirectional Operation : Protects against both positive and negative voltage transients
-  Low Clamping Voltage : Effective voltage limitation during surge events
-  Robust Construction : Axial lead package suitable for automated assembly
 Limitations: 
-  Limited Continuous Power : Not designed for continuous overvoltage conditions
-  Parasitic Capacitance : ~150pF typical may affect high-frequency signal integrity
-  Physical Size : Axial package may require more board space than surface-mount alternatives
-  Voltage Derating : Requires careful consideration of operating temperature effects
## 2. Design Considerations
### Common Design Pitfalls and Solutions
 Pitfall 1: Incorrect Voltage Rating Selection 
-  Problem : Selecting VRWM too close to normal operating voltage
-  Solution : Ensure VRWM (88.1V) exceeds maximum normal operating voltage by 10-20%
 Pitfall 2: Inadequate Thermal Management 
-  Problem : Overheating during repeated transient events
-  Solution : Provide sufficient copper area for heat dissipation and consider derating at elevated temperatures
 Pitfall 3: Poor Placement 
-  Problem : TVS located too far from protected component
-  Solution : Place TVS as close as possible to the point of entry for transients
### Compatibility Issues with Other Components
 Power Supply Compatibility: 
- Compatible with 48V DC systems and below (considering derating)
- May require series resistors with sensitive analog circuits
 Signal Line Considerations: 
- Capacitance may affect high-speed data lines (>10MHz)
- For high-frequency applications, consider low-capacitance TVS alternatives
 System Integration: 
- Coordinate with other protection devices (fuses, varistors) for comprehensive protection
- Ensure coordination with system ground references
### PCB Layout Recommendations
 Placement Strategy: 
- Position immediately after connectors or entry points
- Minimize trace length between TVS and protected circuit (<25mm ideal)
 Routing Guidelines: 
- Use wide traces (≥1mm) for power connections
- Maintain adequate clearance (≥2mm) between high-voltage nodes
- Implement separate ground connections for TVS and protected circuitry
 Thermal Management: 
- Provide at least 100mm² of copper pour for heat dissipation
- Consider thermal vias for multilayer boards
- Avoid placing heat-sensitive components adjacent to TVS
## 3. Technical