IC Phoenix
 
Home ›  MM109 > MC33368DR2,High Voltage GreenLine Power Factor Controller
MC33368DR2 Fast Delivery,Good Price
Part Number:
If you need More Quantity or Better Price,Welcom Any inquiry.
We available via phone +865332716050 Email
Partno Mfg Dc Qty AvailableDescript
MC33368DR2MOTN/a1500avaiHigh Voltage GreenLine Power Factor Controller
MC33368DR2MOTORMLN/a294avaiHigh Voltage GreenLine Power Factor Controller


MC33368DR2 ,High Voltage GreenLine Power Factor Controller
MC33368DR2 ,High Voltage GreenLine Power Factor Controller
MC33368DR2G , High Voltage GreenLine TM Power Factor Controller
MC33368P ,HIGH VOLTAGE GREENLINEE POWER FACTOR CONTROLLEROrder this document by MC33368/D** **HIGH VOLTAGE * *  GREENLINE POWER FACTOR CONTROLLER** *Th ..
MC33375D-2.5 ,300mA, 5V, Low Dropout Voltage Regulator with On/Off ControlMC33375300 mA, Low DropoutVoltage Regulator withOn/Off ControlThe MC33375 series are micropower low ..
MC33375D-3.0 ,300mA, 5V, Low Dropout Voltage Regulator with On/Off Controlpackages, SOT−223, and SOP−8 surface mount packages. Thesedevices feature a very low quiescent curr ..
MC74HC4053FL2 ,8-Channel Analog Multiplexer/DemultiplexerLOGIC DIAGRAMControl InputsMC74HC4052SelectDouble–Pole, 4–Position Plus Common OffEnable B A ON Cha ..
MC74HC4053FR1 ,8-Channel Analog Multiplexer/DemultiplexerMAXIMUM RATINGS*ÎÎÎÎÎSymbol Parameter Value UnitThis device contains protectionÎcircuitry to guard ..
MC74HC4053FR2 ,8-Channel Analog Multiplexer/DemultiplexerLOGIC DIAGRAMControl InputsMC74HC4052SelectDouble–Pole, 4–Position Plus Common OffEnable B A ON Cha ..
MC74HC4060 ,14-Stage Binary Ripple Counter With Oscillator2MC74HC4060ADC CHARACTERISTICS (Voltages Referenced to GND)Guaranteed LimitV VCC CCV VSymbol Symbol ..
MC74HC4060A ,14-Stage Binary Ripple Counter with OscillatorMaximum Ratings are those values beyond which damage to the device may occur.ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ..
MC74HC4060AD ,14-Stage Binary Ripple Counter With Oscillator


MC33368DR2
GreenLine™ Compact Power Factor Controller: Innovative Circuit for Cost Effective Solutions
AND8123/D
Power Factor Correction
Stages Operating in Critical
Conduction Mode
Prepared by: Joel Turchi

ON Semiconductor
This paper proposes a detailed and mathematical analysis
of the operation of a critical conduction mode Power factor
Corrector (PFC), with the goal of easing the PFC stage
dimensioning. After some words on the PFC specification
and a brief presentation of the main critical conduction
schemes, this application note gives the equations necessary
for computing the magnitude of the currents and voltages
that are critical in the choice of the power components.
INTRODUCTION

The IEC1000−3−2 specification, usually named Power
Factor Correction (PFC) standard, has been issued with the
goal of minimizing the Total Harmonic Distortion (THD) of
the current that is drawn from the mains. In practice, the
legislation requests the current to be nearly sinusoidal and in
phase with the AC line voltage.
Active solutions are the most effective means to meet the
legislation. A PFC pre−regulator is inserted between the
input bridge and the bulk capacitor. This intermediate stage
is designed to output a constant voltage while drawing a
sinusoidal current from the line. In practice, the step−up (or
boost) configuration is adopted, as this type of converter is
easy to implement. One can just notice that this topology
requires the output to be higher than the input voltage. That
is why the output regulation level is generally set to around
400 V in universal mains conditions.
Basics of the Critical Conduction Mode

Critical conduction mode (or border line conduction
mode) operation is the most popular solution for low power
applications. Characterized by a variable frequency control
scheme in which the inductor current ramps to twice the
desired average value, ramps down to zero, then
immediately ramps positive again (refer to Figures 2 and 4),
this control method has the following advantages: Simple Control Scheme: The application requires few
external components. Ease of Stabilization: The boost keeps a first order
converter and there is no need for ramp compensation. Zero Current Turn On: One major benefit of critical
conduction mode is the MOSFET turn on when the
diode current reaches zero. Therefore the MOSFET
switch on is lossless and soft and there is no need for
a low trr diode.
On the other hand, the critical conduction mode has some
disadvantages: Large peak currents that result in high dl/dt and rms
currents conducted throughout the PFC stage. Large switching frequency variations as detailed in
the paper.
Diode Bridge
Line
PFC Stage
Figure 1. Power Factor Corrected Power Converter

PFC boost pre−converters typically require a coil, a diode and a Power Switch. This stage also needs a Power Factor Correction
controller that is a circuit specially designed to drive PFC pre−regulators. ON Semiconductor has developed three controllers
(MC33262, MC33368 and MC33260) that operate in critical mode and the NCP1650 for continuous mode applications.