IC Phoenix
 
Home ›  MM70 > MAX6640AEE+-MAX6640AEE+T,2-Channel Temperature Monitor with Dual Automatic PWM Fan-Speed Controller
MAX6640AEE+-MAX6640AEE+T Fast Delivery,Good Price
Part Number:
If you need More Quantity or Better Price,Welcom Any inquiry.
We available via phone +865332716050 Email
Partno Mfg Dc Qty AvailableDescript
MAX6640AEE+ |MAX6640AEEMAXN/a140avai2-Channel Temperature Monitor with Dual Automatic PWM Fan-Speed Controller
MAX6640AEE+T |MAX6640AEETMAXIMN/a1795avai2-Channel Temperature Monitor with Dual Automatic PWM Fan-Speed Controller


MAX6640AEE+T ,2-Channel Temperature Monitor with Dual Automatic PWM Fan-Speed ControllerFeaturesThe MAX6640 monitors its own temperature and one ♦ Two Thermal-Diode Inputsexternal diode-c ..
MAX6642ATT90+ ,±1°C, SMBus-Compatible Remote/Local Temperature Sensor with Overtemperature AlarmFeaturesThe MAX6642 precise, two-channel digital temperature• Integrated Temperature Sensor Enables ..
MAX6642ATT92+ ,±1°C, SMBus-Compatible Remote/Local Temperature Sensor with Overtemperature AlarmElectrical Characteristics(V = +3.0V to +5.5V, T = -40°C to +125°C, unless otherwise specified. Typ ..
MAX6642ATT94+ ,±1°C, SMBus-Compatible Remote/Local Temperature Sensor with Overtemperature AlarmApplicationsMAX6642ATT9E-T -40°C to +125°C 6 TDFN-EP*Desktop ComputersT = Tape and reel.Notebook Co ..
MAX6642ATT98 ,±1°C, SMBus-Compatible Remote/Local Temperature Sensor with Overtemperature AlarmGeneral Description Benefits and
MAX6642ATT98+T ,±1°C, SMBus-Compatible Remote/Local Temperature Sensor with Overtemperature AlarmEVALUATION KIT AVAILABLE±1°C, SMBus-Compatible Remote/MAX6642Local Temperature Sensor withOvertempe ..
MB3752 ,Voltage Regulatorllllll5lllgllllglllgllllllllllllllll FUJITSU VOLT GE M83752 REGULATOR gllllllglllllllllillli ..
MB3756 ,VOLTAGE REGULATORilligllllllllligllliillll FUJITSU V0 RBI M33756 jlllllllllillglilillillillil REGULATOR VOL ..
MB3759 ,Switching Regulator Controller (Switchable between push-pull and single-end functions)FEATURES• Drives a 200 mA load• Can be set to push-pull or single-end operation• Prevents double pu ..
MB3759P ,Switching Regulator Controller (Switchable between push-pull and single-end functions)FEATURES• Drives a 200 mA load• Can be set to push-pull or single-end operation• Prevents double pu ..
MB3759PF ,Switching Regulator Controller (Switchable between push-pull and single-end functions)FUJITSU SEMICONDUCTORDS04-27200-6EDATA SHEETASSP For Power Management
MB3761 ,VOLTAGE DETECTORFUJITSU SEMICONDUCTORDS04-27300-2EDATA SHEETASSPVOLTAGE DETECTORMB3761VOLTAGE DETECTORDesigned for ..


MAX6640AEE+-MAX6640AEE+T
2-Channel Temperature Monitor with Dual Automatic PWM Fan-Speed Controller
General Description
The MAX6640 monitors its own temperature and oneexternal diode-connected transistor or the temperatures
of two external diode-connected transistors, typicallyavailable in CPUs, FPGAs, or GPUs. The 2-wire serial
interface accepts standard System Management Bus
(SMBusTM) write byte, read byte, send byte, andreceive byte commands to read the temperature data
and program the alarm thresholds. Temperature datacan be read at any time over the SMBus, and three pro-
grammable alarm outputs can be used to generate
interrupts, throttle signals, or overtemperature shut-down signals.
The temperature data is also used by the internal dual
PWM fan-speed controller to adjust the speed of up to
two cooling fans, thereby minimizing noise when thesystem is running cool, but providing maximum cooling
when power dissipation increases. Speed control isaccomplished by tachometer feedback from the fan, so
that the speed of the fan is controlled, not just the PWM
duty cycle. Accuracy of speed measurement is ±4%.
The MAX6640 is available in 16-pin QSOP and 16-pinTQFN 5mm x 5mm packages. It operates from 3.0V to
3.6V and consumes just 500μA of supply current.
Applications

Desktop Computers
Notebook Computers
Workstations
Servers
Networking Equipment
Features
Two Thermal-Diode InputsLocal Temperature Sensor1°C Remote Temperature Accuracy (+60°C to
+100°C)
Two PWM Outputs for Fan Drive (Open Drain; can
be Pulled Up to +13.5V)
Programmable Fan-Control CharacteristicsAutomatic Fan Spin-Up Ensures Fan StartControlled Rate-of-Change Ensures Unobtrusive
Fan-Speed Adjustments
±4% Fan-Speed Measurement AccuracyTemperature Monitoring Begins at POR for Fail-
Safe System Protection
OTand THERMOutputs for Throttling or
Shutdown
Measures Temperatures Up to +150°CTiny 5mm x 5mm 16-Pin TQFN and QSOP
Packages
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
Ordering Information

19-3344; Rev 2; 10/08
EVALUATION KIT
AVAILABLE
PARTO PER A T IN G A NG EEA SU R EM EN T A N G E
PIN-
PACKAGE
AX6640AE E +-40°C to
+125°C0°C to +150°C16 QSOPAX6640ATE +-40°C to
+125°C0°C to +150°C16 TQFN- EP*
PWM1SCL
SDA
I.C.
DXP2
DXN
GND
DXP1
TOP VIEW
MAX6640
QSOP

TACH1
PWM2
TACH2
VCC
FANFAIL
THERM
ALERTPWM21
TACH22
FANFAIL
THERM
I.C.11
DXP2
DXN78
GND
DXP1
PWM11413
SDASCLTACH1
ALERT
MAX6640
*CONNECT EXPOSED
PAD TO GND
5mm x 5mm THIN QFN+
Pin Configurations

SMBus is a trademark of Intel Corp.
Typical Operating Circuit appears at end of data sheet.

+Denotes a lead-free/RoHS-compliant package.
*EP = Exposed pad.
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS

(VCC= +3.0V to +3.6V, TA= 0°C to +125°C, unless otherwise noted. Typical values are at VCC= +3.3V,TA= +85°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
VCCto GND..............................................................-0.3V to +6V
PWM1, PWM2, TACH1, and TACH2 to GND......-0.3V to +13.5V
DXP1 and DXP2 to GND..........................-0.3V to +(VCC+ 0.3V)
DXN to GND..........................................................-0.3V to +0.8V
SCL, SDA, THERM, OT, FANFAIL,
and ALERTto GND..............................................-0.3V to +6V
SDA, OT, THERM, ALERT, FANFAIL,
PWM1, and PWM2 Current.............................-1mA to +50mA
DXN Current.......................................................................±1mA
ESD Protection (all pins, Human Body Model)..................2000V
Continuous Power Dissipation (TA= +70°C)
16-Pin QSOP (derated 8.3mW/°C above +70°C).......667mW
16-Pin TQFN 5mm x 5mm
(derated at 33.3mW/°C above +70°C)................2666.7mW
Operating Temperature Range.........................-40°C to +125°C
Junction Temperature......................................................+150°C
Storage Temperature Range.............................-65°C to +150°C
Lead Temperature (soldering, 10s).................................+300°C
PARAMETERSYMBOLCONDITIONSMINTYPMAXUNITS

Operating Supply Voltage RangeVCC+3.0+3.6V
Standby CurrentSMB static, sleep mode310μA
Operating CurrentInterface inactive, ADC active0.51mA
VCC = +3.3V, +60°C ≤ TA ≤ +100°C and
+60°C ≤ TR ≤ +100°C±1
VCC = +3.3V, +40°C ≤ TA ≤ +100°C and
0°C ≤ TR ≤ +145°C±2.5External Temperature Error
VCC = +3.3V,
0°C ≤ TR ≤ +145°C±3.8
VCC = +3.3V,
+25°C ≤ TA ≤ +100°C±2
Internal Temperature Error
VCC = +3.3V,
0°C ≤ TA ≤ +125°C±4
Supply Sensitivity of Temperature
Measurement±0.2°C/V
+0.125°CTemperature Resolution11Bits
Conversion Time125ms
Conversion-Rate Timing Error-10+10%
PWM Frequency Error-10+10%
Tachometer AccuracyVCC = 3.135V to 3.345V,
+60°C ≤ TA ≤ +85°C±4%
High level70100130Remote-Diode Sourcing CurrentLow level7.01013.0μA
DXN Source Voltage0.7V
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
ELECTRICAL CHARACTERISTICS (continued)

(VCC= +3.0V to +3.6V, TA= 0°C to +125°C, unless otherwise noted. Typical values are at VCC= +3.3V,TA= +85°C.) (Note 1)
PARAMETERSYMBOLCONDITIONSMINTYPMAXUNITS
DIGITAL INPUTS AND OUTPUTS

ALERT, FANFAIL, THERM, OT
SDA ISINK = 6mA0.4Output Low Voltage (Sink
Current) (OT, ALERT, FANFAIL,
THERM, SDA, PWM1, and PWM2)
VOL
PWM1, PWM2, ISINK = 4mA0.4
Output High Leakage Current
(OT, ALERT, FANFAIL, THERM,
SDA, PWM1, and PWM2)
IOH1μA
Logic-Low Input Voltage (SDA,
SCL, THERM, TACH1, TACH2)VIL0.8V
Logic-High Input Voltage (SDA,
SCL, THERM, TACH1, TACH2)VIHVCC = 3.3V2.1V
Input Leakage Current (SDA,
SCL, THERM, TACH1, TACH2)VIN = VCC or GND1μA
Input CapacitanceCIN5pF
SMBus TIMING (Note 2)

Serial Clock FrequencyfSCL(Note 3)10100kHz
Clock Low PeriodtLOW10% to 10%4μs
Clock High PeriodtHIGH90% to 90%4.7μs
Bus Free Time Between Stop and
Start ConditiontBUF4.7μs
SMBus Start Condition Setup
TimetSU:STA90% of SMBCLK to 90% of SMBDATA4.7μs
Start Condition Hold TimetHD:STO10% of SDA to 10% of SCL4μs
Stop Condition Setup TimetSU:STO90% of SCL to 10% of SDA4μs
Data Setup TimetSU:DAT10% of SDA to 10% of SCL250ns
Data Hold TimetHD:DAT10% of SCL to 10% of SDA (Note 4)300ns
SMBus Fall TimetF300ns
SMBus Rise TimetR1000ns
SMBus TimeouttTIMEOUT587490ms
Note 1:
All parameters tested at a single temperature. Specifications are guaranteed by design.
Note 2:
Timing specifications guaranteed by design.
Note 3:
The serial interface resets when SCL is low for more than tTIMEOUT.
Note 4:
A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCL's falling edge.
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
Typical Operating Characteristics

(VCC= 3.3V, TA= +25°C.)
STANDBY SUPPLY CURRENT
vs. SUPPLY VOLTAGE

MAX6640 toc01
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (
OPERATING SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX6640 toc02
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (
REMOTE TEMPERATURE ERROR
vs. REMOTE-DIODE TEMPERATURE
MAX6640 toc03
TEMPERATURE (°C)
TEMPERATURE ERROR (
°C)
FAIRCHILD 2N3906
LOCAL TEMPERATURE ERROR
vs. DIE TEMPERATURE

MAX6640 toc04
TEMPERATURE (°C)
TEMPERATURE ERROR (
LOCAL TEMPERATURE ERROR
vs. POWER-SUPPLY NOISE FREQUENCY
MAX6640 toc06
FREQUENCY (Hz)
TEMPERATURE ERROR (
10k1k100
-2.010100k
VIN = 250mVP-P SQUARE WAVE APPLIED TO
VCC WITH NO BYPASS CAPACITOR
REMOTE TEMPERATURE ERROR
vs. COMMON-MODE NOISE FREQUENCY

MAX6640 toc07
TEMPERATURE ERROR (
10k1k100
0.1110100k
VIN = AC-COUPLED TO DXP AND DXN
VIN = 100mVP-P SQUARE WAVE
REMOTE TEMPERATURE ERROR
vs. DIFFERENTIAL NOISE FREQUENCY

MAX6640 toc08
TEMPERATURE ERROR (
10k1k100
-2.0100k
VIN = AC-COUPLED TO DXP
VIN = 100mVP-P SQUARE WAVE
TEMPERATURE ERROR
vs. DXP-DXN CAPACITANCE

MAX6640 toc09
TEMPERATURE ERROR (1
REMOTE TEMPERATURE ERROR
vs. POWER-SUPPLY NOISE FREQUENCY
MAX6640 toc05
FREQUENCY (Hz)
TEMPERATURE ERROR (
10k1k100
-2.0100k
VIN = 250mVP-P SQUARE WAVE APPLIED TO
VCC WITH NO BYPASS CAPACITOR
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
PIN
TQFN-EPQSOPNAMEFUNCTION

1, 153, 1PWM2,
PWM1
Open-Drain Output to Power Transistor Driving Fan. Connect to the gate of a MOSFET or base of a
bipolar transistor. PWM_ requires a pullup resistor. The pullup resistor can be connected to a
supply voltage as high as 13.5V, regardless of the MAX6640’s supply voltage.
2, 164, 2TACH2,
TACH1
Tachometer Inputs. Connect to the tachometer output of the fan. TACH_ requires a pullup resistor.
The pullup resistor can be connected to a supply voltage as high as 13.5V, regardless of the
MAX6640’s supply voltage.FANFAILActive-Low, Open-Drain, Fan-Failure Output. Open circuit when VCC = 0.THERMActive-Low, Open-Drain Thermal Alarm Output. Typically used for clock throttling. Open circuit
when VCC = 0.OTActive-Low, Open-Drain Overtemperature Output. Typically used for system shutdown or clock
throttling. Can be pulled up to 5.5V regardless of VCC. Open circuit when VCC = 0.VCCPower-Supply Input. 3.3V nominal. Bypass VCC to GND with a 0.1μF capacitor.10GNDGround. Connect to a clean ground reference.
8, 109, 12DXP1,
DXP2
Combined Current Source and A/D Positive Input for Remote Diode. Connect to anode of remote-
diode-connected temperature-sensing transistor. Do not leave unconnected; connect to DXN if no
remote diode is used. Place a 2200pF capacitor between DXP_ and DXN for noise filtering.11DXNCombined Current Sink and A/D Negative Input for Remote Diode. Connect cathode of the remote-
diode-connected transistor to DXN.13I.C.Internally Connected. Connect to VCC.14ALERTActive-Low, Open-Drain SMBus Alert Output16SCLS M Bus S er i al - C l ock Inp ut. C an b e p ul l ed up to 5.5V r eg ar d l ess of V C C . O p en ci r cui t w hen V C C = 0.15SDASMBus Serial-Data Input/Output, Open Drain. Can be pulled up to 5.5V regardless of VCC. Open
circuit when VCC = 0.EPExposed Pad (TQFN package only). Internally connected to GND. Connect to a large ground
plane to maximize thermal performance. Not intended as an electrical connection point.
Pin Description
Typical Operating Characteristics (continued)

(VCC= 3.3V, TA= +25°C.)
PWMOUT FREQUENCY
vs. DIE TEMPERATURE

MAX6640 toc10
TEMPERATURE (°C)
PWMOUT FREQUENCY (Hz)603510-15
PWMOUT FREQUENCY
vs. SUPPLY VOLTAGE
MAX6640 toc11
SUPPLY VOLTAGE (V)
PWMOUT FREQUENCY (Hz)
3.05.5
MAX6640
Detailed Description

The MAX6640 monitors its own temperature and a
remote diode-connected transistor or the temperatures
of two external diode-connected transistors, which typi-
cally reside on the die of a CPU or other integrated cir-
cuit. The 2-wire serial interface accepts standard
SMBus write byte, read byte, send byte, and receive
byte commands to read the temperature data and pro-
gram the alarm thresholds. Temperature data can be
read at any time over the SMBus, and a programmable
alarm output can be used to generate interrupts, throt-
tle signals, or overtemperature shutdown signals.
The temperature data is also used by the internal dual
PWM fan-speed controller to adjust the speed of up to
two cooling fans, thereby minimizing noise when the
system is running cool, but providing maximum cooling
when power dissipation increases. RPM feedback
allows the MAX6640 to control the fan’s actual speed.
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller

GND
SMBus
INTERFACE AND
REGISTERS
LOGIC
PWM
GENERATOR
BLOCK
VCC
TEMPERATURE
PROCESSING
BLOCK
SDA
SCL
DXP1
DXN
PWM1
PWM2
TACH1
TACH2
DXP2
THERM
FANFAIL
ALERT
MAX6640
Block Diagram
Write Byte Format
Read Byte Format
Send Byte FormatReceive Byte Format

Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
Command Byte: selects which
register you are writing to
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
Slave Address: equiva-
lent to chip-select line
Command Byte: selects
which register you are
reading from
Slave Address: repeated
due to change in data-
flow direction
Data Byte: reads from
the register set by the
command byte
Command Byte: sends com-
mand with no data, usually
used for one-shot command
Data Byte: reads data from
the register commanded
by the last Read Byte or
Write Byte transmission;
also used for SMBus Alert
Response return address
S = Start conditionShaded = Slave transmission
P = Stop condition/// = Not acknowledged
Figure 1. SMBus ProtocolsADDRESSRDACKDATA///P
7 bits8 bitsSACKCOMMANDACKP
8 bits
ADDRESS

7 bits
ACKDATA

8 bits
ACKCOMMAND

8 bits
ACKWRADDRESS

7 bitsADDRESSWRACKCOMMANDACKSADDRESS
7 bits8 bits7 bitsACKDATA
8 bits
///P
SMBus Digital Interface
From a software perspective, the MAX6640 appears as
a set of byte-wide registers. This device uses a stan-
dard SMBus 2-wire/I2C-compatible serial interface to
access the internal registers. The MAX6640 has a fixed
slave address of 0101111.
The MAX6640 employs four standard SMBus protocols:
write byte, read byte, send byte, and receive byte
(Figures 1, 2, and 3). The shorter receive byte protocol
allows quicker transfers, provided that the correct data
register was previously selected by a read byte instruc-
tion. Use caution with the shorter protocols in multimas-
ter systems, since a second master could overwrite the
command byte without informing the first master.
Table 3 details the register addresses and functions,
whether they can be read or written to, and the power-
on reset (POR) state. See Tables 4–8 for all other regis-
ter functions and the Register Descriptionssection.
Temperature Reading

Temperature data can be read from registers 00h and
01h. The temperature data format for these registers is
8 bits, with the LSB representing 1°C (Table 1) and the
MSB representing +128°C. The MSB is transmitted first.
Three additional temperature bits provide resolution
down to 0.125°C and are in the channel 1 extended
temperature (05h) and channel 2 extended temperature
(06h) registers. All values below 0°C clip to 00h.
The MAX6640 employs a register lock mechanism to
avoid getting temperature results from the temperature
register and the extended temperature register sam-
pled at two different time points. Reading the extended
register stops the MAX6640 from updating the tempera-
ture register for at least 0.25s, unless there is a temper-
ature register read before the scheduled update. This
allows enough time to read the main register before it is
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller

SCL
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVECDEFGHIJ
SDA
tSU:STAtHD:STA
tLOWtHIGH
tSU:DATtSU:STOtBUFK
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
Figure 2. SMBus Write Timing Diagram
SCLCDEFGHIJK
SDA
tSU:STAtHD:STA
tLOWtHIGH
tSU:DATtHD:DATtSU:STOtBUF
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW M
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
Figure 3. SMBus Read Timing Diagram
MAX6640
updated, thereby preventing reading the temperature
register data from one conversion and the extended
temperature register data from a different conversion.
The MAX6640 measures the temperature at a fixed rate
of 4Hz immediately after it is powered on. Setting bit 7
of the configuration register (04h) shuts down the tem-
perature measurement cycle.Output
When a measured temperature exceeds the corre-
sponding OTtemperature threshold and OTis not
masked, the associated OTstatus register bit sets and
the OToutput asserts. If OTfor the respective channel
is masked, the OTstatus register sets, but the OTout-
put does not assert. To deassert the OToutput and the
associated status register bit, either the measured tem-
perature must fall at least 5°C below the trip threshold
or the trip threshold must be increased to at least 5°C
above the current measured temperature.
THERM

When a measured temperature exceeds the corre-
sponding THERMtemperature threshold and THERMis
not masked, the associated THERMstatus register bit
is set and the THERMoutput asserts. If THERMfor the
respective channel is masked, the THERMstatus regis-
ter is set, but the THERMoutput does not assert. To
deassert the THERMoutput and the associated status
register bit, either the measured temperature must fall
at least 5°C below the trip threshold or the trip threshold
must be increased to at least 5°C above the current
measured temperature. Asserting THERMinternally or
externally forces both PWM outputs to 100% duty cycle
when bit 6 in address 13h (fan 1) or bit 6 in address
17h (fan 2) is set.
ALERT

The ALERToutput asserts to indicate that a measured
temperature exceeds the ALERTtrip threshold for that
temperature channel. The status bit and the ALERTout-
put clear by reading the ALERTstatus register. If the
ALERTstatus bit is cleared, but the temperature still
exceeds the ALERTtemperature threshold, ALERT
reasserts on the next conversion, and the status bit sets
again. A successful alert response protocol clears
ALERT, but does not affect the ALERTstatus bit.
TACH1 and TACH2 Inputs

To measure the fan speed, the MAX6640 has two
tachometers. Each tachometer has an accurate internal
clock to count the time elapsed in one revolution.
Therefore, it is counting the time between two tachome-
ter pulses for a fan with four poles. When the PWM sig-
nal is used to directly modulate the fan’s power supply,
the PWM frequency is normally in the 20Hz to 100Hz
range. In this case, the time required for one revolution
may be longer than the PWM on-time. For this reason,
the PWM pulses are periodically stretched to allow
tachometer measurement over a full revolution. Turn off
pulse stretching by setting bit 5 of register 13h or regis-
ter 17h when using a 4-wire fan.
The tachometer count is inversely proportional to the
fan’s RPM. The tachometer count data is stored in regis-
ter 20h (for TACH1) and register 21h (for TACH2).
Reading a value of 255 from the TACH count register
means the fan’s RPM is zero or too slow for the range.
Reading a value of zero in the TACH count register
means the fan’s RPM is higher than the range selected.
Table 2 shows the fan’s available RPM ranges. Use reg-
isters 10h or 14h to select the appropriate RPM range for
the fan being used.
FANFAIL

The FANFAILoutput asserts to indicate that one of the
fans has failed or is spinning slower than the required
speed. The MAX6640 detects fan fault depending on
the fan control mode. In PWM mode, the MAX6640 pro-
duces a square wave with a duty cycle set by the value
written to the duty-cycle registers (26h and 27h). In this
mode, the MAX6640 signals a fan fault when the
tachometer count is greater than the maximum
tachometer count value stored in the appropriate regis-
ter (22h and 23h). After the MAX6640 asserts FANFAIL,
the fan with a tachometer fault goes to full speed for 2s in
an attempt to restart the fan and then returns to the origi-
nal duty-cycle settings. Reading the status register clears
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
TEMP (°C)TEMP (°C)DIGITAL OUTPUT

241+2411111 0001
240+2401111 0000
126+1260111 1110+250001 1001
1.5010000 0001
0.0000000 0000
Table 1. Temperature Data Byte Format
FAN RPM
RANGE
INTERNAL CLOCK
FREQUENCY (kHz)

16,0008
Table 2. Tachometer Setting
the FANFAILstatus bits and the output. The MAX6640
measures the fan speed again after 2s. The MAX6640
asserts FANFAILif it detects the fan fault again.
In RPM mode (either automatic or manual), the
MAX6640 checks for fan failure only when the duty
cycle reaches 100%. It asserts FANFAILwhen the
tachometer count is greater than twice the target
tachometer count. In manual RPM mode, registers 22h
and 23h store the target tachometer count value. In
automatic RPM mode, these registers store the maxi-
mum tachometer count.
Fan-Speed Control

The MAX6640 adjusts fan speed by controlling the duty
cycle of a PWM signal. This PWM signal then either
modulates the DC brushless fan’s power supply or dri-
ves a speed-control input on a fan that is equipped with
one. There are three speed-control modes: PWM, in
which the PWM duty cycle is directly programmed over
the SMBus; manual RPM, in which the desired
tachometer count is programmed into a register and
the MAX6640 adjusts its duty cycle to achieve the
desired tachometer count; and automatic RPM, in
which the tachometer count is adjusted based on a
programmed temperature profile.
The MAX6640 divides each PWM cycle into 120 time
slots. Registers 26h and 27h contain the current values
of the duty cycles for PWM1 and PWM2, expressed as
the effective time slot length. For example, the PWM1
output duty cycle is 25% when register 26h reads 1Eh
(30/120).
PWM Control Mode

Enter PWM mode by setting bit 7 of the fan 1 or 2 con-
figuration 1 register (10h and 14h) to 1. In PWM control
mode, the MAX6640 generates PWM signals whose
duty cycles are specified by writing the desired values
to fan duty-cycle registers 26h and 27h. When a new
duty-cycle value is written into one of the fan duty-cycle
registers, the duty cycle changes to the new value at a
rate determined by the rate-of-change bits [6:4] in the
fan 1 or 2 configuration 1 register. The rate-of-change
of the duty cycle ranges from 000 (immediately
changes to the new programmed value) to 111
(changes by 1/120 every 4s). See Table 4 and the Fan
1 and 2 Configuration 1 (10h and 14h)section.
Manual RPM Control Mode

Enter manual RPM control mode by setting bits 2, 3,
and 7 of the fan 1 or 2 configuration 1 register (10h and
14h) to zero. In the manual RPM control mode, the
MAX6640 adjusts the duty cycle and measures the fan
speed. Enter the target tachometer count in register
22h for fan 1 and register 23h for fan 2. The MAX6640
compares the target tachometer count with the mea-
sured tachometer count and adjusts the duty cycle so
that the fan speed gradually approaches the target
tachometer count.
The first time manual RPM control mode is entered, the
initial PWM duty cycle is determined by the target
tachometer count:
where targetTACH is the value of the target tachometer
count in the target tach count register (22h or 23h).
If the initial duty cycle value is over 120, the duty cycle
is 100%. If spin-up is enabled (bit 7 in registers 13h
and 17h) and the fan is not already spinning, the duty
cycle first goes to 100% and then goes to the initial
duty-cycle value. Every 2s, the MAX6640 counts the
fan’s period by counting the number of pulses stored in
registers 24h and 25h. If the count is different from the
target count, the duty cycle is adjusted.
If a nonzero rate-of-change is selected, the duty cycle
changes at the specified rate until the tachometer count
is within ±5 of the target. Then the MAX6640 gets into a
locked state and updates the duty cycle every 2s.
Automatic RPM Control Mode

In the automatic RPM control mode, the MAX6640 mea-
sures temperature, sets a target tachometer count
based on the measured temperature, and then adjusts
the duty cycle so the fan spins at the desired speed.
Enter this mode by setting bit 7 of the fan 1 or 2 config-
uration 1 register (10h and 14h) to zero and selecting
the temperature channel that controls the fan speed
using bits 2 and 3 of the configuration register.
In both the RPM modes (automatic and manual), the
MAX6640 implements a low limit for the tachometer
counts. This limits the maximum speed of the fan by
ensuring that the fan’s tachometer count does not go
lower than the tachometer count specified by bits 5
through 0 of register 24h for fan 1 and register 25h for
fan 2. Typical values for the minimum tachometer count
are 30h to 60h. Set the value to correspond to the full-
rated RPM of the fan. See Figure 4.
Figure 5 shows how the MAX6640 calculates the target
tachometer value based on the measured temperature.
At TMIN, the fan spins at a minimum speed value corre-
sponding to the maximum tachometer count value
stored in register 22h or 23h. Bit 0 of register 11h (fan
1) and register 15h (fan 2) selects the behavior below
InitialdutycycletetTACHarg=−255
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
MAX6640
TMIN. If bit 0 is equal to zero, the fan will be completely
off below TMIN. When the temperature is falling, it must
drop 5°C below TMINbefore the fan turns off. If bit 0 is
set to 1, the fan does not turn off below TMIN, but
instead stays at the maximum tachometer count in reg-
ister 22h or 23h.
When the measured temperature is higher than TMIN,
the MAX6640 calculates the target tachometer count
value based on two linear equations. The target
tachometer count decreases by the tach step size
value stored in bits 7 through 4 of registers 11h and
15h each time the measured temperature increases by
the temperature step size value stored in bits 2 and 3 of
registers 11h and 15h. As the measured temperature
continues to increase, a second tachometer step size
goes into effect. Bits 3 through 0 of register 12h and
16h select the number temperature/PWM steps after
which the new step size takes effect. The new step size
is selected by bits 7 to 4 of registers 12h and 16h.
Register Descriptions
Channel 1 and Channel 2 Temperature Registers
(00h and 01h)

These registers contain the results of temperature mea-
surements. The MSB has a weight of +128°C and the
LSB +1°C. Temperature data for remote diode 1 is in
the channel 1 temperature register. Temperature data
for remote diode 2 or the local sensor (selectable by bit
4 in the global configuration register) is in the channel 2
temperature register. Three additional temperature bits
provide resolution down to 0.125°C and are in the
channel 1 extended temperature (05h) and channel 2
extended temperature (06h) registers. The channel 1
and channel 2 temperature registers do not update until
at least 250ms after the access of the associated
extended temperature registers. All values below 0°C
return 00h.
Status Register (02h)

A 1 indicates that an ALERT, THERM, OT, or fan fault has
occurred. Reading this register clears bits 7, 6, 1, and 0.
Reading the register also clears the ALERTand
FANFAILoutputs, but not the THERMand OToutputs. If
the fault is still present on the next temperature measure-
ment cycle, any cleared bits and outputs are set again. A
successful alert response clears the values on the out-
puts but does not clear the status register bits. The
ALERTbits assert when the measured temperature is
higher than the respective thresholds. The THERMandoutputs behave like comparators with 5°C hysteresis.
Mask Register (03h)

This register masks the ALERT, OT, THERM, and
FANFAILoutputs. A 1 prevents the corresponding fail-
ures from being asserted on these outputs. The mask
bits do not affect the status register.
Global Configuration Register (04h)

The global configuration register controls the shutdown
mode, power-on reset, SMBus timeout, and tempera-
ture channel 2 source select:D7: Run/Standby.Normal operation is run(0).
Setting this bit to 1 suspends conversions and puts
the MAX6640 into low-power sleep mode.D6: Software POR.Writing a 1 resets all registers to
their default values.
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller

TACHMAX
TACH
0xFFh
TACHMIN
TEMPERATURETBTMIN-5TMIN
TACHB+1
TACHA+1
Figure 4. Tachometer Target Calculation
RPM
RPMMAX
RPMMIN
TEMPERATURE
TMIN-5TMINTB
TACHA+1
TACHB+1
Figure 5. RPM Target Calculation
MAX6640
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
READ/
WRITE
REGISTER
NO.
ADDRESS
POR
STATEFUNCTIOND7D6D5D4D3D2D1D 0
00h0000
Temperature
channel 1
MSB
(+128°C)——————LS B1° C ) 01h0000
Temperature
channel 2
MSB
(+128°C)——————LS B1° C ) 02h0000
0000Status byteChannel 1
ALERT
Channel 2
ALERT
Channel 1
Channel 2
Channel 1
THERM
Channel 2
THERMFan 1 faultFan 2
faul t
R/W03h0000
0011Output maskChannel 1
ALERT
Channel 2
ALERT
Channel 1
Channel 2
Channel 1
THERM
Channel 2
THERMFan 1 faultFan 2
faul t
R/W04h0011
Global
configuration
Run
0 = run,
1= stby
POR
1 = reset
SMBus
timeout
0 =
enabled,
1 =
disabled
Tem p
channel 2
sour ce:
1 = l ocal ,
0 = r em ote
ReservedReservedReservedReser ved 05h0000
Channel 1
extended
temperature
MSB
(0.5°C)—LSB
(0.125°C)ReservedReservedReservedReservedD i od e
faul t06h0000
Channel 2
extended
temperature
MSB
(0.5°C)—LSB
(0.125°C)ReservedReservedReservedReservedD i od e
faul t
R/W08h0101
Channel 1
ALERT limitMSB——————LS B1° C )
R/W09h0101
Channel 2
ALERT limitMSB——————LS B1° C )
R/W0Ah0110
Channel 1 OT
limitMSB——————LS B1° C )
R/W0Bh0110
Channel 2 OT
limitMSB——————LS B1° C )
R/W0Ch0101
Channel 1
THERM limitMSB——————LS B1° C )
R/W0Dh0101
Channel 2
THERM limitMSB——————LS B1° C )
R/W10h1000
Fan 1
configuration
PWM
mode
Rate of
change
(MSB)
Rate of
change
Rate of
change
(LSB)
Fan 1
channel 1
control
Fan 1
channel 2
control
RPM
range
select
RP M ang e
sel ect
R/W11h0000
Fan 1
Configuration
RPM step-
size A
(MSB)
RPM step-
size A
RPM step-
size A
RPM step-
size A
(LSB)
Temp
step-size
A (MSB)
Temp
step-size
A (LSB)
PWM
100% duty
cyclei ni m um
fan
sp eed
0 = 0%,
1= val uen 22h
Table 3. Register Map
ic,good price


TEL:86-533-2716050      FAX:86-533-2716790
   