GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR VOLTAGE - 5.0 TO 180 Volts 5000Watts Peak Pulse Power

Partnumber Manufacturer Quantity Availability
5KP90A GS 3590 In Stock

Description and Introduction

GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR VOLTAGE - 5.0 TO 180 Volts 5000Watts Peak Pulse Power The part 5KP90A is a transient voltage suppressor (TVS) diode manufactured by General Semiconductor (GS). Here are the key specifications:

- **Part Number:** 5KP90A
- **Manufacturer:** General Semiconductor (GS)
- **Type:** Transient Voltage Suppressor (TVS) Diode
- **Peak Pulse Power:** 5000W (5kW)
- **Breakdown Voltage (V_BR):** 100V (minimum) to 111V (maximum)
- **Standoff Voltage (V_RWM):** 90V
- **Maximum Clamping Voltage (V_C):** 146V at 77.3A
- **Peak Pulse Current (I_PP):** 77.3A
- **Operating Temperature Range:** -55°C to +175°C
- **Package:** DO-201AD (DO-27)

These specifications are typical for the 5KP90A TVS diode, designed to protect electronic circuits from voltage transients and surges.

Application Scenarios & Design Considerations

GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR VOLTAGE - 5.0 TO 180 Volts 5000Watts Peak Pulse Power # Technical Documentation: 5KP90A Transient Voltage Suppressor (TVS) Diode

*Manufacturer: GS*

## 1. Application Scenarios

### Typical Use Cases
The 5KP90A is a 5000W transient voltage suppressor diode designed for robust overvoltage protection in demanding electronic systems. Typical applications include:

 Primary Use Cases: 
-  AC/DC Power Supply Protection : Installed across AC input lines to suppress lightning-induced transients and power cross events
-  Telecommunications Equipment : Protects DSL modems, routers, and telephone line interfaces from voltage spikes
-  Industrial Control Systems : Guards PLCs, motor drives, and sensor interfaces against ESD and electrical fast transients
-  Automotive Electronics : Provides load dump protection for ECUs, infotainment systems, and charging interfaces
-  Renewable Energy Systems : Protects solar inverters and wind power converters from switching surges

### Industry Applications
 Telecommunications : Deployed in base station equipment, network switches, and customer premises equipment to meet ITU-T K.20/K.21 standards for surge immunity.

 Industrial Automation : Used in factory automation systems, process control instrumentation, and motor drives complying with IEC 61000-4-5 surge requirements.

 Consumer Electronics : Integrated into high-end audio/video equipment, gaming consoles, and smart home devices requiring robust ESD protection per IEC 61000-4-2.

 Power Distribution : Applied in smart meters, power quality monitors, and grid monitoring equipment.

### Practical Advantages and Limitations

 Advantages: 
-  High Power Handling : 5000W peak pulse power capability (10/1000μs waveform)
-  Fast Response Time : Typically <1.0 picosecond reaction to transient events
-  Low Clamping Ratio : Provides effective voltage limiting during surge events
-  Bidirectional Operation : Suitable for AC line applications without polarity concerns
-  High Temperature Stability : Maintains performance across -55°C to +175°C range

 Limitations: 
-  Parasitic Capacitance : ~500pF typical capacitance may affect high-frequency signal integrity
-  Physical Size : DO-201AD package requires adequate PCB space allocation
-  Limited Precision : Not suitable for precision voltage reference applications
-  Degradation : Repeated surge events may cause gradual performance degradation

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Improper Voltage Rating Selection 
-  Problem : Selecting VRWM too close to operating voltage, causing premature activation
-  Solution : Ensure VRWM (90V) exceeds maximum continuous operating voltage by 10-20%

 Pitfall 2: Inadequate Thermal Management 
-  Problem : High-energy transients generating excessive heat in compact layouts
-  Solution : Implement thermal relief patterns and consider heatsinking for high-surge environments

 Pitfall 3: Incorrect Placement 
-  Problem : Placing TVS too far from protected circuitry, reducing effectiveness
-  Solution : Position within 1-2 cm of protection point with minimal trace inductance

### Compatibility Issues with Other Components

 With Varistors: 
-  Issue : Potential coordination conflicts during surge events
-  Resolution : Use 5KP90A as primary protection, varistors as secondary, with appropriate decoupling

 With Fuses: 
-  Issue : Fast-acting fuses may blow during legitimate surge suppression
-  Resolution : Select slow-blow fuses rated above maximum surge current

 With Ferrite Beads: 
-  Issue : Inductance may delay TVS response time
-  Resolution : Place beads upstream of TVS, not between TVS and protected circuit

### PCB Layout Recommendations

 Placement Strategy: 
- Position immediately at board entry points for I/O lines and power inputs

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips