IC Phoenix
 
Home ›  332 > 3B16-01,Non-Isolated Strain Gage Input; 3 Hz Bandwidth Signal Conditioning Module
3B16-01 Fast Delivery,Good Price
Part Number:
If you need More Quantity or Better Price,Welcom Any inquiry.
We available via phone +865332716050 Email
Partno Mfg Dc Qty AvailableDescript
3B16-01 |3B1601ADN/a2avaiNon-Isolated Strain Gage Input; 3 Hz Bandwidth Signal Conditioning Module


3B16-01 ,Non-Isolated Strain Gage Input; 3 Hz Bandwidth Signal Conditioning Modulefeatures two simultaneous outputs, the voltage output can be Torque Transducers, Frequency Transduc ..
3B18-00 ,Non-Isolated Strain Gage Input; 20 kHz Bandwidth Signal Conditioning ModuleGENERAL DESCRIPTION both voltage and current outputs. The 3B18 is a wideband (20kHz) single-channe ..
3B18-01 ,Non-Isolated Strain Gage Input; 20 kHz Bandwidth Signal Conditioning Modulefeatures two simultaneous outputs, the voltage output can be without the inherent noise, non-linear ..
3B20-01 ,Non-Isolated AC Strain or Torque Input Signal Conditioning ModuleGENERAL DESCRIPTION selecting resistors, a Windows program, 3B-CUSTOM, The 3B20 is a wideband sin ..
3B41 ,Isolated Wide Bandwidth Volt Input Signal Conditioning Moduleapplications requiring simultaneous precision voltage and current outputs. Each high-resolution mea ..
3B41-03 ,Isolated Wide Bandwidth Volt Input Signal Conditioning Modulefeatures two simultaneous outputs, the voltage output can be linearize and convert the transducer o ..
50217-8000 , 3.50mm (.138") Pitch Crimp Terminal 50217, 18-24 AWG, Reel, Phosphor Bronze
502MLF , LOCO™ PLL CLOCK MULTIPLIER
50474C , Surface Mount Common Mode Chokes
50475C , Surface Mount Common Mode Chokes
5082/2800 ,Schottky Barrier Diodes for General Purpose ApplicationsCharacteristics1.93 (.076)1.73 (.068)AvailableThe 5082-2300 Series and5082-2900 devices are unpas-D ..
5082/2835 ,Schottky Barrier Diodes for General Purpose ApplicationsApplicationsTechnical Data1N57111N57125082-2300 Series5082-2800 Series5082-2900


3B16-01
Non-Isolated Strain Gage Input; 3 Hz Bandwidth Signal Conditioning Module
Narrow Bandwidth Strain Gage InputRev. 0
FEATURES
Interfaces, amplifies, & filters signals from 4-arm full-bridge
strain-gage bridges with a resistance from 300Ω to 1 kΩ.
Module provides a constant +10V bridge excitation voltage.
Module provides simultaneous precision voltage and
current outputs.
Module circuitry can withstand 130v rms at the input screw-
terminals
All 3B16 series modules are mix-and-match and Hot
Swappable

APPLICATIONS
Industrial signal conditioning
Industrial signal isolation
Industrial signal filtering

PRODUCT OVERVIEW

The 3B Series of Signal Conditioning I/o Subsystems provide a
low-cost, versatile method of transferring analog transducer
signals to a data acquisition, monitoring or control system
without the inherent noise, non-linearity, drift and extraneous
voltages. The modules are designed to directly accept analog
signals from Thermocouples, RTD’s, AC and DC Strain Gages,
Torque Transducers, Frequency Transducers, LVDTs, millivolt
or process current signals. The modules amplify, isolate,
linearize and convert the transducer output signals to
standardized analog inputs for high-level analog I/O
subsystems. The 3B Series Subsystem consists of a 10” relay
rack with universal mounting backplane and a family of plug-in
(up to 16 per rack) input and output signal conditioning
modules.
Eight and four channel backplanes are also available. Each
backplane incorporates screw terminals for sensor inputs and
current outputs and a 26-pin connector for high-level single-
ended voltage outputs to the user’s equipment.
The input modules feature complete signal conditioning
circuitry optimized for specific sensors or analog signals and
provide two simultaneous high-level analog outputs: 0 to +10V
(or +10V) and 4-20 mA (or 0-20 mA).
FUNCTIONAL BLOCK DIAGRAM

Figure 1. 3B16 Functional Block Diagram
Output modules accept 0 to +10V (or +10V) single-ended
signals and provide an isolated 4-20 mA (or 0-20 mA) process
signal. All modules feature a universal pin-out and may be
readily hot-swapped under full power and interchanged without
disrupting field wiring.
The Analog Devices 3B Series Signal Conditioning Subsystem is
designed to easily handle signal conditioning problems in
measurement and control applications. Some typical uses are in
microcomputer-based data acquisition systems, programmable
controllers, analog recorders, dedicated control systems, and any
other applications where monitoring of temperature, pressure,
flow and analog signals are required. Since each input module
features two simultaneous outputs, the voltage output can be
used to provide an input to a microprocessor-based data
acquisition or control system while the current output can be
used for analog transmission, operator interface, or an analog
backup system.
Each input module is a single-channel signal conditioner which
plugs into a socket on the backplane and accepts its signal from
the input screw terminals. All input modules provide input
protection, amplification and filtering of the input signal,
accuracy of +0.1%, low drift of +1 uV/ oC (low-level input
modules), and feature two high-level analog outputs that are
compatible with most process instrumentation. The isolated
input modules also provide +1500 V peak isolation.
The choice of a specific 3B module depends upon the type of
input signal. Input modules are available to accept millivolt, volt,
process current, thermocouple, RTD, AC and DC strain gage,
frequency and LVDT inputs. The voltage output of each module
is available from the system I/O connector while the current
output is available on the output screw terminals.
GENERAL DESCRIPTION
The 3B16 is a single-channel signal conditioning module which
interfaces, amplifies, and filters signals from 4-arm full-bridge
strain-gage bridges with a resistance from 300W to 1kW. The
module provides a constant +10V bridge excitation voltage and
provides simultaneous precision voltage and current outputs.
The user-configurable Model 3B16-00 can be applied in
applications involving large tare weights which must be
compensated with zero suppression. The 3B16 protects the
computer side from damage due to field-side over-voltage faults
up to 130V rms. In addition, the current output withstands
130V rms without damage and interfaces user equipment
through screw terminals located on the 3B Series backplane.
The 3B16 is a plug-in, mix-and-match, hot-swappable module
which is easily field calibrated via front-panel zero and span
adjustments for both voltage and current outputs.
3B Series Custom-Ranging Program – Externally-
programmable Model 3B16-00, enables the user to configure a
special input range, including tare weight suppression, by using
the optional plug-on AC1310 ranging card, which houses user-
supplied resistors to determine zero and span. To facilitate
selecting resistors, a Windows program, 3B-CUSTOM,
calculates resistor values based on the user-desired input/output
ranges.
A chopper-stabilized low-drift (+1uV/oC) input amplifier
assures long-term stability. At the amplifier input, a stable, zero-
scale input voltage is subtracted from the input signal to set the
zero-scale value. Zero suppression can exceed 100% of the input
range. This is ideal for expanded-scale applications requiring
high-resolution measurement of a selected portion of an input
signal. For user convenience, the zero and span can be factory
configured to meet custom range needs (Model 3B16-
CUSTOM) or can be externally programmed (Model 3B16-00)
via user supplied resistors inserted in the optional AC1310 plug-
on ranging card. Internal low-pass filtering with a 3 Hz cutoff
(-3dB) two-pole Butterworth filter enhances a 60 dB normal-
mode rejection at 50/60 Hz, enabling accurate measurement of
small signals in high electrical noise.
.
.
Figure 2
3B16 Models Available
Model Input
Bridge
Input
Range
Excitation Sensitivity Output
Ranges1
3B16-00
Full Bridge Externally
Programmable2
+10 V Externally
Programmable2
-10 V to +10 V &
0 mA to 20 mA
3B16-01
Full Bridge -30 mV to +30 mV +10 V 3 mV/V -10 V to +10 V & 0 mA to 20 mA
3B16-Custom
Full Bridge * +10 V * * Output current range may be user programmed to 4 mA to 20 mA using jumper supplied. 2 Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
3B16 Specifications

(typical @ +25°C and ±15 V dc, and +24 V dc Power)
Description Model 3B16
Input Range

Standard Range ±30 mV (3 mV/V sensitivity @ Vexc = +10V)
Custom Ranges ±5 mV to ±500 mV
Output Range

Voltage (RL > 2 KΩ) -10 V to +10 V
Current (RL = 0 to 850Ω)1 4 mA to 20 mA or 0 mA to 20 mA
Maximum Current Output Span 0 mA to 31 mA
Accuracy2

Initial @ +25°C ±0.1% Span
Nonlinearity2 ±0.01% Span
Stability vs. Temperature

Voltage Output
Zero ±3 µV/°C (RTI)
Span ±25 ppm of Reading/°C
Current Output3
Zero ±25 ppm of Span/°C
Span ±25 ppm of Reading/°C
Bridge Excitation

Voltage +10 V
Voltage, tolerance ±2%
Vexc= +10.0 V 300 Ωto 1 kΩ
Zero and Span Adjustment Range4
±5% of Span
Input Bias Current
+3 nA
Input Resistance
100 MΩ
Noise

Input, 0.1 Hz to 10 Hz Bandwidth 0.2 µV rms
Output, 100 kHz Bandwidth 50 µV rms
Bandwidth, -3 dB
3 Hz
Output Rise Time, 10% to 90% Span
200 ms
Common-Mode Voltage (CMV)

Input-to-Output, Continuous ±10 V peak, maximum
Transient ANSI/IEEE C37.90.1-1989
Normal Mode Rejection @ 50/60 Hz
60 dB
Input Protection, Signal and Excitation Voltage

Continuous 130 V rms maximum
Trasient ANSI/IEEE C37.90.1-1989
Voltage Output Protection
Continuous Short to Ground
Current Output Protection
130 V rms, continuous
Power Supply Voltages 5

±15 V dc Supplies
Rated Operation ±(12.7 V dc to 16.5 V dc)
Current +45 mA, -10 mA
Sensitivity ±0.01% span/V
+24 V dc Loop Supply
Rated Operation +12 V dc to +30 V dc
Current +27 mA @ lout = 20 mA
Sensitivity ±0.0002% span/V
Mechanical Dimensions
3.15" x 3.395" x 0.775"
80.0 mm x 86.2 mm x 19.7 mm)
Environmental

Temperature Range
Rated Performance -25°C to +85°C
Storage -55°C to +85°C
Relative Humidity, 24 hours 0 to 95% @ +60°C noncondensing
RFI Susceptibility ±0.5% Span error @ 400 MHz, 5 Watt, 3 ft For a 0 mA to 20 mA range, a typical minimum output current is 10 µA. Includes the combined effects of repeatability, hysteresis, and nonlinearity. 3 With respect to the voltage output. A wide range of custom zero suppression and span is available with the 3B16-00 model, using the AC1310 ranging card. +24 V dc loop power is required for driving the current output at loads up to 850Ω. If a current output load of 400Ω or less is applied, +15 V dc is sufficient for loop power. If only
voltage output is used, loop power is not required.
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS
Figure 3 3B16 Input Field Connections
Table 1. Pin Function Descriptions—

Figure 4 . Model 3B Series Module, with pin-out assignments.
ESD CAUTION

ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human
body and test equipment and can discharge without detection. Although this product features proprietary ESD
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
OUTLINE DIMENSIONS
Figure 5. Outline Dimensions
ic,good price


TEL:86-533-2716050      FAX:86-533-2716790
   

©2020 IC PHOENIX CO.,LIMITED