VIPER16LDTR ,Energy Saving VIPer Plus: 6W high voltage converter with direct feedbackVIPER16Fixed frequency VIPer™ plus familyDatasheet - production data• Standby power < 30 mW at 230 ..
VIPER17HD ,VIPer Plus family: fixed frequancy high performance off line high voltage converterelectrical characteristics . . . . . . 116 Typical circuit . . . . . 147 Operation descrip ..
VIPER17HDTR ,VIPer Plus family: fixed frequancy high performance off line high voltage converterApplications SO16 narrowDIP-7SO-16• Adapters for PDA, camcorders, shavers, cellular phones, videoga ..
VIPER17LD ,VIPer Plus family: fixed frequancy high performance off line high voltage converterBlock diagram . . . . . . 32 Typical power . . . . . . . 33 Pin settings 44 Elect ..
VIPER17LDTR ,VIPer Plus family: fixed frequancy high performance off line high voltage converterFeaturesoperation and the device’s very low consumption meet the standby energy saving regulations. ..
VIPER17LN ,VIPer Plus family: fixed frequancy high performance off line high voltage converterVIPER17Energy saving VIPerPlus: HV switching regulator for flybackconverterDatasheet - production d ..
W83L351G , ExpressCard™ Power Interface Switch
W83L351YCG , ExpressCard™ Power Interface Switch
W83L517D-F , LPC I/O for Notebook
W83L603G , SMBus GPIO Controller
W83L771ASG , W83L771AWG W83L771ASG Nuvoton H/W Monitoring IC
W83L771ASG , W83L771AWG W83L771ASG Nuvoton H/W Monitoring IC
VIPER16HD-VIPER16HDTR-VIPER16HN-VIPER16LD-VIPER16LDTR
Energy Saving VIPer Plus: 6W high voltage converter with direct feedback
June 2014 DocID15232 Rev 7 1/30
VIPER16Fixed frequency VIPer™ plus family
Datasheet - production data
Figure 1. Typical application
Features 800 V avalanche rugged power section PWM operation with frequency jittering for low
EMI Operating frequency: 60 kHz for L type 115 kHz for H type No need of auxiliary winding for low power
application Standby power < 30 mW at 230 VAC Limiting current with adjustable set point On-board soft-start Safe auto-restart after a fault condition Hysteretic thermal shutdown
Application Replacement of capacitive power supply Auxiliary power supply for appliances, Power metering LED drivers
DescriptionThe device is an off-line converter with an 800 V
avalanche ruggedness power section, a PWM
controller, user defined overcurrent limit,
protection against feedback network
disconnection, hysteretic thermal protection, soft
start up and safe auto restart after any fault
condition. It is able to power itself directly from the
rectified mains, eliminating the need for an
auxiliary bias winding. Advance frequency jittering
reduces EMI filter cost. Burst mode operation and
the devices very low consumption both help to
meet the standard set by energy saving
regulations.
Table 1. Device summary
Contents VIPER162/30 DocID15232 Rev 7
Contents Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Typical power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Pin settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74.1 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.2 Thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.3 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Typical electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Typical circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Power section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 High voltage current generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Soft start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Adjustable current limit set point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 FB pin and COMP pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Burst mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Automatic auto restart after overload or short-circuit . . . . . . . . . . . . . 20 Open loop failure protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DocID15232 Rev 7 3/30
VIPER16 Contents Layout guidelines and design recommendations . . . . . . . . . . . . . . . . 23 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Block diagram VIPER16
4/30 DocID15232 Rev 7
1 Block diagram
2 Typical power
Figure 2. Block diagram
Table 2. Typical power Typical continuous power in non ventilated enclosed adapter measured at 50 °C ambient. Maximum practical continuous power in an open frame design at 50 °C ambient, with adequate heat
sinking.
DocID15232 Rev 7 5/30
VIPER16 Pin settings
3 Pin settings
Figure 3. Connection diagram (top view)
Note: The copper area for heat dissipation has to be designed under the DRAIN pins.
Table 3. Pin description