TC9307AF-010 ,SINGLECHIP DTS MICRO CONTROLLER (DTS-12)
TC9308 ,DTS MICRO CONTROLLER CONTAINING PLL.LCD DRIVER
TC9309AF ,SINGLE CHIP DTS MICROCONTROLLER (DTS-10)
TC9309AF-125 ,SINGLE CHIP DIGITAL TUNING SYSTEM FOR 3 DISC CD CHANGER UNIT
TC9309F-106 ,SINGLE CHIP DIGITAL TUNING SYSTEM FOR CD RADIO CASSETTE
TC9309F-106 ,SINGLE CHIP DIGITAL TUNING SYSTEM FOR CD RADIO CASSETTE
TDA7416 ,CARRADIO SIGNAL PROCESSORFEATURESInput multiplexer– 1 pseudo differential CDC stereo input, programmable as single-ended inp ..
TDA7417 ,Audio ProcessorElectrical characteristics . . . . . . . 94 Description of the audioprocessor . . . . 134.1 ..
TDA7418 ,3 BAND CAR AUDIO PROCESSORBlock diagram . . . . . . 62 Pin description . . . . . 72.1 Connection diagram . . ..
TDA7418 ,3 BAND CAR AUDIO PROCESSORElectrical characteristics . . . . 8Table 5. Registers of all subaddresses . . . . . . . ..
TDA7418TR ,3 BAND CAR AUDIO PROCESSORFeatures• Input multiplexer– PD/SE4: pseudo differential stereo input, programmable as single-ended ..
TDA7419 ,3 BAND CAR AUDIO PROCESSORFeatures:Input Multiplexer QD / SE: quasi-differential stereo inputs, with selectable single-ended ..
TC9307AF-010
SINGLECHIP DTS MICRO CONTROLLER (DTS-12)
TOSHIBA
TC9307AF-010
SINGLECHIP DTS MICRO CONTROLLER (DTS-12)
TOSHIBA CMOS DIGITAL INTEGRATED CIRCUIT SILICON MONOLITHIC
TC9307AF-01l0
The TC9307AF-010 is a digital tuning system optimum for such portable audio equipment as radio
with a cassette tape recorder, and is provided with 4 bands of FM/SW/MW/LW and compatible
with worldwide destinations.
FEATURES
C) RECEIVING BAND
AREA JT, 'E2dfll1'y, BAND Fdtfl11(1hHz, STEPIHZ] FRERoElh'tyYclu//12r'h1E/?)AJ?z,
USA1 0 0 0 - FM 87.5~107.9M 200k 25k +10.7M
MW 530-- 1710k 10k 5k +450k
FM 87.5-- 108.0M 100k 25k +10.7M
USA2 0 01 - MW 530-- 1710k 10k 5k +450k
0/1 FM 87.50--108.00M 50/ 100k 25k +10.7M
0 531~ 1602k 9k 3k
'fer- 0 1 0 1 MW 530-- 1610k 10k 5k +450k
LW 146-- 281k 1k 1k
- sw 5.95-- 15.6M 5k 5k
on FM 87.50--108.00M 50/ 100k 25k +10.7M
EUROPE 0 1 1 0 MW 531~ 1602k 9k 3k
1 530-- 1610k 10k 5k +450k
- LW 146-- 281k 1k 1k
on FM 87.50--108.00M 50/ 100k 25k +10.7M
MIDDLE 0 MW 531~ 1602k 9k 3k
EAST 1 0 0 1 530-- 1610k 10k 5k +450k
- SW1 2.3~ 6.2M 5k 5k
SW2 7.1~ 21.85M
on FM 87.50--108.00M 50/ 100k 25k +10.7M
0 531~ 1602k 9k 3k
1ttf," 1 0 1 1 MW 530-- 1610k 10k 5k +450k
LW 146-- 281k 1k 1k
- sw 3.8-- 12.5M 5k 5k
on FM 87.50--108.00M 50/ 100k 25k +10.7M
AUSTRALIA1 1 0 0 MW 531~ 1602k 9k 3k +450k
1 530-- 1610k 10k 5k
2001 -06-1 9
TOSHIBA
TC9307AF-010
CODE STEP RECEIVING REFERENCE INTERMEDIATE
AREA E0 E1 E2 JAMPER BAND FREQUENCY [Hz] STEP [Hz] FREQUENCY [Hz]FREQUENCY [Hz]
0/ 1 FM 87.00~108.00M 50/ 100k 25k +10.7M
CHINA 1 1 1 - MW 531-- 1602k 9k 3k
- SW1 2.3-- 6.2M 5k 5k +450k
SW2 7.1~ 21.85M
C) FUNCTIONAL OUTLINE
It Manual Up/Down Tuning
It Auto Up/Down Tuning (seek system)
0 IF counter system auto stop function.
0 Auto tuning in SW band is the scan system in the meter band.
It Band changeover of method to which either of momentary or lock switch is selectable.
o ON/OFF timer by time set system.
0 12-hour/24-hour clock
0 Sleep timer (max 90 min.)
0 snooze (within 2 hours)
2001 -06-1 9
TOSHIBA TC9307AF-010
TC9307AF-010 Layout
I CLOCK I I TIMER I IONTIMEI IOFFTIMEII SLEEP MEMORY l
FM MW AM
LW MHz
SW 2 PM 0 MHz
S12 S11 S10 S9 S8 $7 S6 S5 S4 S1 COM4 COM3 COM2 COM1
I Il I I I I I I 'l ll I
-lit3 11L
- I IPF M)
B. - +
sLEEpouT--I TC9307AF 010 T
TIMER OUT -r MINI FLAT PACKAGE 44P|N
BS FORMING T3
BAND 1 --I TOP VIEW T2
BAND 0 --I
MUTE -I
IF IN -M--r
0.01m K3
M 44 K2
I I I I I I I I I
1.1.1. o _
LPF st St
I 1000pF
(sr/yi)??,')
FORMAT EO E1 E2
'l',,,, x "sr,, N,
BAND SNOOZE
B t STEP OUT ENA.
i", g 3 OWF x\ 1: E
+ 5 + it TEST ngm/ FAST UP/MIN
it 5 'u, l; 'sr, 'u,
l) g 'tk 'vs. K K _
g "MEMORY M1 M2 l M3
''il" Vi' \x \\
K K K "
M4 M5 SNOOZE SLEEP
"tks'. "til" "Cir," "c;
K N, 's, K
MODE ON/OFF BAND SHIFT
bvl,v1,vb
3 2001-06-19
TOSHIBA
TC9307AF-010
KEY MAP
T0 T1 T2 T3 T4 T5
k? * E2 UP min M3 SLEEP SHIFT
K2 * E1 * SNOOZE FAST M2 SNOOZE BAND
ENABLE
K1 * EO *BAND OUT 0:3,“ MI M5 0mg;
K0 * TIME * 9k TEST MEMORY M4 MODE
FORMAT 10k
* Diodejumper
LCD MAP
CLOCK TIMER ON-TIME a OFF-TIME SLEEP MEMORY
FM MW AM MHz
LW MHz
sw 1 PM e g c 0 kHz
1 2 3 4 5
SEGMENT NAME
SYMBOL PIN No. COM1 COM2 COM3 COM4 COMMENT
Slit 26 5 FM. MHz kHz PM 21.84§MHz
s11 25 SW. MHz : 2 CLOCK sw 2
s10 24 MW 1 LW AM sw 1
Sg 23 1c 1adeg 1b TIMER 21.845MHz
S8 22 2d 2e 2f ON-TIME
Sy 21 2c 2g 2b 2a 21.845MHz
S6 20 3d 3e 3f OFF-TIME
21. 4 MH
S5 19 3c 3g 3b 3a , 5 z
s4 18 4d 4e 4f SLEEP
S3 16 4c 4g 4b 4a 21.845MHz
Sit 15 5d 5e 5f MEMORY
SI 14 5c 5g 5b 5a PRESET CH
2001 -06-1 9
TOSHIBA TC9307AF-010
PUSH KEY
SYMBOL FUNCTIONAL DESCRIPTION
FREQ : Press briefly, frequency will be advanced by one step at each time this
UP min button pressed. Press continuously for more than Is., seek-up tuning mode is
result. Scanner looks for the nearest station with sufficient signal strength.
TIME : When correcting a time or setting a timer, MINUTE digit is set.
FREQ : Simultaneously pressing UP (or DOWN) button and FAST button will
FAST accelerates the manual tuning. Seek tuning mode will be disable when FAST
button is pressed.
FREQ : Press briefly, frequency will be advanced by one step at each time this
button pressed. Press continuously for more than Is., seek-down tuning
DOWN hour mode is result. Scanner looks for the nearest station with sufficient signal
strength.
TIME : When correcting a time or setting a timer, HOUR digit is set.
FREQ : While this button is pressed, memory write function is enabled for a time
period of 4s. After the time period, memory write function will disable
automatically.
MEMORY TIME : Continuously pressing this button will enable time or timer correction
function. Time or timer correction function will be disable again once this
button is released. This is a security function to avoid misalignment of the
time or timer accidentally.
When [BAND OUT] jumper is valid, briefly press this button will alter the radio band
in a cyclic function.
MI--M5 Address to a memory location when recall a preset memory or write to a memory.
For some destinations, 10 preset memories is provided. [SHIFT] key is useful for the
SHIFT addressing of M6-M10. To do so, push SHIFT key and then push M1-M5.
As long as this key is kept pushed, all indications on LCD are kept ON. Further, this
(TEST) . . . . .
IS capable of checking the timer and sleep functions by accelerating the clock.
SNOOZE To temporary stop the timer function for a time interval of 9 min. After this time
interval, timer function will resume.
SLEEP timer can be turned ON and OFF by a momentarily switch in a cyclic function.
SLEEP To alter the sleep time, push SLEEP button to activate the SLEEP timer and
continuously pushing this button for more than ls, a sleep time can be set up at an
interval of 0.5s/step like 90, 80, ...... 10, 1, 90.
MODE Switches the operation among FREQUENCY, CLOCK and TIMER mode cyclically.
5 2001-06-19
TOSHIBA TC9307AF-010
FUNCTION (Diode jumper)
SYMBOL FUNCTION DESCRIPTION
Set up a destination
DIODE DESTINATION
E0 E1 E2
0 USA 2
C) General (SW-A type)
EO~E2 C) C) Europe
O Middle & Near East
C) C) General (SW-B type)
C) C) Canada Australia
C) C) C) China
C) : Diode is available
To select 12 hour format or 24 hour format.
Time Format With diode jumper : 24 hour format.
Without diode jumper : 12 hour format.
selects AM/FM step.
Without the jumper : MW 10k/FM 100k step
With the jumper : MW 9k/FM 50k step
However, FM band for USA, Canada, Australia, and MW band for China is fixed step.
With diode jumper :
The band changeover of cyclical method can be carried out by [BAND] key.
BAND OUT Without diode jumper :
Selects receiving bands according to combination of the band input ports BO and
9k 10k
The diode jumper is read when a radio is turned ON or there is key input.
6 2001-06-19
TOSHIBA TC9307AF-010
I/O PORT
PORT No. NAME I/O FUNCTION ACTIVE INIT.
Without [band out] jumper
P10 30 BO IN USA Gen. M.N. EAST Gen. - -
B1 BO Can. SW-A china Euro SW-B
0 0 FM FM FM FM FM
0 1 FM LW SW1 LW LW
PII 29 B1 IN 1 0 MW MW MW MW MW - -
1 1 FM SW-A SW2 FM SW-B
With [band out] jumper
P10 30 BO OUT USA Gen. M.N. EAST Gen. - L
B1 BO Can. SW-A china Euro SW-B
0 0 FM FM FM FM FM
0 1 FM LW SW1 LW LW
PII 29 B1 OUT 1 0 MW MW MW MW MW - L
1 1 FM SW-A SW2 FM SW-B
TIMER . . " " . . .
P12 28 OUT OUT This port IS put at H level during the timer operation. H L
SLEEP . . " n . .
P13 27 OUT OUT This port IS put at H level during the SLEEP period. H L
MUTE 31 MUTE OUT Muting output H L
INH ='H' : radio function is active.
INH 35 INH IN INH ='L' : radio function is stop and clock mode. - -
7 2001-06-19
TOSHIBA
BAND SWITCHING
1. Principal function
Bands are switched.
2. Input ports and keys to be used.
BO, B1, [BAND] key, [band out] diode switch
3. Function
When [band out] diode switch is OFF.
TC9307AF-010
a. Selects receiving bands according to combination of the band input ports BO and B1.
b. Bands selected according to destination are as follows :
INPUT PORT CENSA-ADA EUROPE "gift" GENERAL (1) GENERAL (2)
p11 p10 (2 BAND) (3 BAND) (4 BAND) (4 BAND) (4 BAND)
0 0 FM FM FM FM FM
0 1 (FM) LW SW1 LW LW
1 0 AM MW MW MW MW
1 1 (FM) (FM) SW2 SW-A SW-B
When [band out] diode switch is ON.
a. When [BAND OUT] jumper is valid, briefly press this button will alter the radio in a cyclic
function.
Europe area Middle Near East & China area
I:FM -"Iw_-"ve FM - W - W ->'V'W
l" S 1 S 2 T
Other area U.S.A & Canada area
FM -SW-MW--LW
EFM -Ahll Cl
8 2001-06-19
TOSHIBA
MANUAL TUNING
1. Principal function
1 push/1 step tuning by [UP]/[DOWN] key.
2. Input ports and keys to be used.
[UP] key, [DOWN] key, [FAST] key
3. Function
1 push/1 step tuning by [UP]/[DOWN] key.
b. Tuning is continuously carried out when [UP]/[DOWN] key is kept pushed continuously for more
than 1 second.
TC9307AF-010
c. When [FAST] key is kept pushed together with [UP]/[DOWN] key, the high speed continuous
tuning results. During the high speed continuous tuning, the continuous tuning up/down step
frequency normally changes as follows :
STEP FREQUENCY
BAND SCAN TIME NORMAL ACCELERATED
100kHz 200kHz
FM 100ms/STEP 50kHz 200kHz
9kHz 18kHz
MW 200ms/STEP 10kHz 20kHz
LW 200ms/STEP 1kHz 2kHz
SW 200ms/STEP 5kHz 100kHz
However, in SW band, if frequency below 0.1MHz is not zero when [UP]/[DOWN] key and
[FAST] key are pushed, after the up/down tuning as follows, the up/down tuning at 100kHz is
carried out.
In case of 16.555MHz
[UP] + [FAST]
16.555MHz-916.600MHz-916.700MHz--9
[DOWN] + [FAST]
16.555MHz-y16.500MHz-y16.400MHz---y
d. During the continuous tuning, any other key input is not accepted and even a broadcasting
station is detected, it is not stopped.
If the upper limit frequency is reached, it shifts toward the lower limit frequency and when the
lower limit frequency is reached, it shifts toward the upper limit frequency.
At this time, the system stops for 500ms as frequency.
2001 -06-1 9
TOSHIBA TC9307AF-010
AUTO SEARCH TUNING
1. Principal function
Continuously pressing [UP]/[DOWN] key for Is, auto seek function will be activated.
2. Input ports and keys to be used.
[UP] key, [DOWN] key
3. Function
a. Continuously pressing [UP] key for 1s, auto seek-up function will be activated. Similarly,
Continuously pressing [DOWN] key for ls, auto seek-down function will be activated.
b. The auto tuning speed is the same as the continuous tuning speed. However, in the SW band,
the inside of the meter band only is scanned at 5kHz per step.
C. If STOP signal is detected by IF counter input, the tuning stops at that frequency.
d. Meter band frequencies in SW band are as follows :
BAND FREQUENCY STEP BAND FREQUENCY STEP
2.300-- 2.495 5.950-- 6.200
3.200-- 3.400 7.100-- 7.300
SW1 3.900-- 4.000 SkHz 9.500-- 9.900
4.750-- 5.060 SW-A 11.650--12.050 5kHz
5.950-- 6.200 13.600--13.800
7.100-- 7.300 15.100--15.600
9.500s 9.900
11.650--12.050 BAND FREQUENCY STEP
SW2 13.600--13.800 5kHz
15.100--15.600 3.900-- 4.000
17.550--17.900 4.750-- 5.060
21.450--21.850 - 5.950-- 6.200
SW B 7.100~ 7.300 5kHz
9.500-- 9.900
10 2001-06-19
TOSHIBA TC9307AF-010
PRESET MEMORY
Principal function
The number of preset memories set up by destination can be realized.
Input ports and keys to be used.
[M1]~[M5] key : Specification for Middle Near East and China
[M1]~[M5] key, [SHIFT] key (M6--M10) .' Specification for other zones
Function
a. When [MII-HMS] keys for the specifications for the Middle Near East and China are pushed, the
pushed preset memories are read out.
b. For the specification for other areas, when [M1]~[M10] keys are pushed, the pushed preset
memories are read out. In this case, [M6]~[M10] keys become effective by pushing [M1]~[M5]
keys after pushing [SHIFT] key.
Pushing [SHIFT] key result in the shift mode but no indication is made, and the shift mode is
released when [SHIFT] key is pushed again.
c. When [MEMORY] key is pushed, 'MEMORY' indication lights for 4s. and during this period if the
preset key is pushed, a frequency is written in that preset memory and lighting of 'MEMORY'
indication ends.
'MEMORY' indication also goes out by any key input other than [SHIFT] key and [FAST] key and
the write status is canceled.
d. Preset number is indicated on LCD but in case of CH 10, '0' is indicated.
e. Destinations, receiving bands and number of preset memory channels are as follows :
DIODE SW
EO E1 E2 FM MW LW sw SW1 SW2 REMARK
10 10 - - - - USA 1
C) 10 IO - - - - USA 2
O 10 5 5 5 - - Gen. SW-A
C) O 10 5 5 - - - Europe
C) 5 5 - - 5 5 M.N.East
C) C) 10 5 5 - - Gen. SW-B
C) O 10 10 - - - - Canada
0 C) O 5 5 - - 5 5 China
C) : with diode
11 2001-06-19
TOSHIBA TC9307AF-010
CLOCK FUNCTION
1. Principal function
Corrects a current time.
2. Input ports and keys to be used.
[UP] key, [DOWN] key, [MEMORY] key, [MODE] key
3. Function
a. Sets the clock indication with the [MODE] key.
b. Push the [C-adj] key, the same key as the [MEMO] key. Press the [HOUR] ([MIN]) key in
combination with the [C-adj] key to advance the hour (minute) digit.
c. After timer correction is completed, press the [MODE] key repeatedly until the desired display
mode is shown.
d. When correcting "MIN.", s. is cleared to "00" if any key input is made.
SLEEP TIMER
l. Principal function
The 90 min. sleep timer can be set.
2. Input ports and keys to be used.
[SLEEP] key
3. Function
When [SLEEP] key is pushed, the sleep out (P13) is put at "H" level, 'SLEEP' and a sleep time are
indicated on LCD, and a 90 min. sleep time is set up. Further, if [SLEEP] key is pushed again, the
sleep operation is released and the sleep out (P13) is put at "L" level.
To change a sleep time, directly push [SLEEP] key continuously for more than ls. when setting
the sleep operation. A sleep time can be set up at intervals of 0.5$./step like 90, 80, ... 10, 1,
There is no indication for residual sleep time and if there is not [SLEEP] key input for IOS., the
system returns to a mode before pushing [SLEEP] key.
TIMER FUNCTION
1. Principal function
Setting of the timer ON/OFF time and timer operation. (only SNOOZE disable mode)
2. Input ports and keys to be used.
[TIMER] key, [MODE] key, [HOUR] (UP) key, [MIN] (DOWN) key, [MEMO] key
12 2001-06-19
TOSHIBA TC9307AF-010
3. Function
a. [MODE] key operations among frequency, clock and timer mode cyclically. The timer correction
function is automatically released after IOS. if no key input. Then, a current time is indicated.
I--FREQ---cLock -TIMER ON-TIME-TIMER OFF-TIME-]
To check the ON-TIME (OFF-TIME) of the timer.
To push the [MODE] key repeatedly until the ON-TIME (OFF-TIME) is displayed.
To correct the ON-TIME (OFF-TIME) of the timer.
1. Push the [MODE] key repeatedly until the ON-TIME (OFF-TIME) is displayed.
2. Push the [C-adj] key, the same key as the [MEMO] key, the ON-TIME (OFF-TIME) indicator on
the display will be flicker. Press the [HOUR] ([MIN]) key in combination with the [C-adj] key
to advance the hour (minute) digit.
3. After timer correction is completed, press the [MODE] key repeatedly until the desired display
mode is shown.
b. [TIMER] key operations between TlMER-STANDBY and TIMER-OFF mode cyclically.
SNOOZE FUNCTION
l. Principal function
Setting of the timer ON time and SNOOZE operation.
2. Input ports and keys to be used.
[SNOOZE] key
3. Function
a. When [SNOOZE ena] diode jumper ON, timer function change to snooze function.
[MODE] key operations among frequency, clock and timer mode cyclically. The time correction
function is automatically released after IOS. if no key input. Then, a current time is indicated.
" - IMER N-TIME
I--FREQ CLOCK T O T
b. At the TIMER ON-TIME, timer-out (P12) changes from "L" to "H".
c. If [SNOOZE] key pushed on the TIMER-ON state, timer-out (P12) changes from "H" to "L". After
9 minutes, timer-out (P12) changes from "L" to "H" again. This function is available within 2
hours time.
13 2001-06-19
TOSHIBA
Principal function
In the following cases, mute signal (H active) is output.
Input ports and keys to be used.
Mute port (Pin 31)
Function
In the following cases, mute signal is output for 1s. :
When initializing.
When switching a receiving band.
When calling a preset channel.
When turning a radio OFF or ON (Radio ON/OFF by the INH).
In the following cases, mute signal is output :
In the following cases, no mute signal is output :
During auto up tuning.
TC9307AF-010
When reaching the band edge during manual up/down tuning or continuous tuning.
In the clock mode.
When operating [MEMORY], [FAST], [MODE] or [SHIFT] key.
When writing into a preset channel.
When calling the same preset channel.
2001 -06-1 9
TOSHIBA TC9307AF-010
MUTE OUTPUT TIMING AND PLL DATA
PLL : PLL data set timing
IF : IF count start timing
1. When initializing
[tIT] Input _l
[MUTE] Output l—l PLL DISP I-
l 250-370 30-45 I 9--ll l
I émooqoso
2. When a radio ON/OFF
Radio OFF to ON
[INH] Input _I
[MUTE] Output _I PLL DISP I
40-70 9-ll l l
- 900--1050
Radio ON to OFF
[INH] Input -1
[MUTE] Output _I PLL DISP I
7-ll 9-11 l
"-900--1050
15 2001-06-19
TOSHIBA TC9307AF-010
3. Band change (by slide switch)
[TV] [FM] [AM] EX
[MUTE] Output L PLL DISP I—
25--45 l 9--11
"-90tr-1050
4. Band change (by push switch)
[BAND] keys I I
[MUTE] Output |_l PLL DISP I—
2--20 19-23 l 9--11
-— 900--1050
5. When calling a preset memory
[M1]~[M5] key I I
[MUTE] Output |_I PLL DISP I—
I 2-20 20-23 W-ll l
narrow : count gate time at narrow accuracy=4ms (AM)/1ms (FM)
6. Auto seek tuning
wide : count gate time at wide accuracy=16ms (AM)/4ms (FM)
[UP/DOWN] key I I
[MUTEIOutput l I PLL DISP IF PLL DISP f IF PLL
2-20 20-65 W-ll I
IF check wait IF check wait 90--110
widrle NG Widé OK narrgw NG
scan time 1 scan time 2
[UP/DOWN] key OFF
[MUTE] Output PLL DISP IF IF '—
IF check wait 90-110 540-560 l
I widel OK narr'ow OK I
BAND SCAN TIME 1 [ms] SCAN TIME 2 [ms] IF CHECK WAIT [ms]
FM 95--110 190--205 65--85
AM 190--210 285--305 155--175
(Note) Time of SCAN TIME 1 is about 0.55. wait time when changing from upper
limit frequency to lower limit frequency and about Is. when changing
into SW meter band.
16 2001-06-19
TOSHIBA TC9307AF-010
RESTRICTIONS ON PRODUCT USE
000707EBA
OTOSHIBA is continually working to improve the quality and reliability of its products.
Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent
electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer,
when utilizing TOSHIBA products, to comply with the standards of safety in making a safe
design for the entire system, and to avoid situations in which a malfunction or failure of such
TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified
operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please
keep in mind the precautions and conditions set forth in the "Handling Guide for
Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc..
OThe TOSHIBA products listed in this document are intended for usage in general electronics
applications (computer, personal equipment, office equipment, measuring equipment, industrial
robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor
warranted for usage in equipment that requires extraordinarily high quality and/or reliability or
a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended
Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship
instruments, transportation instruments, traffic signal instruments, combustion control
instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA
products listed in this document shall be made at the customer's own risk.
0 The products described in this document are subject to the foreign exchange and foreign trade
OThe information contained herein is presented only as a guide for the applications of our
products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of
intellectual property or other rights of the third parties which may result from its use. No
license is granted by implication or otherwise under any intellectual property or other rights of
TOSHIBA CORPORATION or others.
0 The information contained herein is subject to change without notice.
17 2001-06-19
:
www.loq.com
.