PCA6107DWR ,Remote 8-Bit I2C and SMBus Low-Power I/O Expander With Interrupt Output, Reset, and Config Registers 18-SOIC -40 to 85 SCPS139E–JANUARY 2006–REVISED JUNE 20144 Description (Continued)The PCA6107 open-drain interrupt ( ..
PCA82C250 ,CAN controller interfaceFeatures and benefits Fully compatible with the “ISO 11898” standard High speed (up to 1 MBd) Bu ..
PCA82C250/N4 ,CAN controller interface
PCA82C250T ,CAN controller interfacePin configurationPCA89C250 All information provided in this document is subject to legal disclaimer ..
PCA82C251 ,CAN transceiver for 24 V systems
PCA82C251 ,CAN transceiver for 24 V systems
PEB4266T-V1.2 , Dual Channel Subscriber Line Interface Concept
PEB4266T-V1.2 , Dual Channel Subscriber Line Interface Concept
PEB55504FV1.1 ,ALIDDApplicationsB-MuSLICPEB 4550 PEB 3554PEB 55504PEB 35508Preliminary Product Overview 05.99•%0X6/,& ..
PEB7274HV1.2 ,QUAD ADPCM (4 Channel ADPCM Controller)characteristics.Terms of delivery and rights to change design reserved.For questions on technology, ..
PEB7274HV1.2 ,QUAD ADPCM (4 Channel ADPCM Controller)Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
PEEL16CV8J-25 , CMOS Programmable Electrically Erasable Logic Device
PCA6107-PCA6107DWR
Remote 8-Bit I2C and SMBus Low-Power I/O Expander With Interrupt Output, Reset, and Config Registers
VCC
VCC
RESET
Product
Folder
Sample &
Buy
Technical
Documents
Tools &
Software
Support &
Community
PCA6107 Operating Power-Supply Voltage Range The PCA6107 consists of one 8-bit Configuration 5.5V (inputor output selection), Input Port, Output Port,
and Polarity Inversion (active high) registers. At• 5-V Tolerant I/O Ports power on, the I/Os are configured as inputs.• 400-kHz FastI2C Bus However, the system master can enable the I/Os as• Three Hardware Address Pins Allow for Use either inputs or outputs by writing to the I/O Eight Deviceson theI2 C/SMBus configuration bits. The data for each inputor outputis
keptin the corresponding inputor output register. The• Input/Output Configuration Register polarityof the Input Port register can be inverted with• Polarity Inversion Register the Polarity Inversion register. All registers can be• Internal Power-On Reset readby the system master. High-Impedance Open Drainon P0 The system master can reset the PCA6107in the• Power Up WithAll Channels Configured eventofa timeout or other improper operation by
assertinga lowin the active-low reset (RESET) input.• No Glitchon Power Up The power-on reset puts the registersin their default• Noise Filteron SCL/SDA Inputs states and initializes theI2 C/SMBus state machine.• Latched Outputs With High-Current Drive Asserting RESET causes the same reset/initializationMaximum Capabilityfor Directly Driving LEDs to occur without depowering the part. Latch-Up Performance Exceeds 100 mA
Device Information(1)JESD 78, ClassII• ESD Protection Exceeds JESD22– 2000-V Human-Body Model (A114-A)
(1) Forall available packages, see the orderable addendumat– 200-V Machine Model (A115-A) the endofthe datasheet. 1000-V Charged-Device Model (C101)