MC10137L ,Universal Decade CounterELECTRICAL CHARACTERISTICSTest LimitsPin Pi–30°C +25°C +85°CUnder UnderCharacteristic Symbol Test U ..
MC10137P ,Universal Decade CounterLOGIC DIAGRAMS1 9S2 710Carry InT K JQ0 Q1 Q2 Q3J T TTT T JQ0 Q1 J Q2 T Q3T C T C T C T C13Clock ..
MC10138 ,Bi-Quinary CounterELECTRICAL CHARACTERISTICSTest LimitsPi Pin–30°C +25°C +85°CUnder UnderCharacteristic Symbol Test U ..
MC10138FN ,Bi-Quinary CounterELECTRICAL CHARACTERISTICSTest LimitsPi Pin–30°C +25°C +85°CUnder UnderCharacteristic Symbol Test U ..
MC10138L ,Bi-Quinary CounterLOGIC DIAGRAM PLASTIC PACKAGECASE 648–08S0 Q0 S1 Q1 S2 Q2 S3 Q311 15 10 13 6 4 5 2FN SUFFIXPLCCCASE ..
MC10138P ,Bi-Quinary CounterELECTRICAL CHARACTERISTICSTest LimitsPi Pin–30°C +25°C +85°CUnder UnderCharacteristic Symbol Test U ..
MC33375D-3.3R2G , 300 mA, Low Dropout Voltage Regulator with On/Off Control
MC33375ST-1.8T3 ,300mA, 5V, Low Dropout Voltage Regulator with On/Off ControlELECTRICAL CHARACTERISTICS (C = 1.0μF, T = 25°C, for min/max values T = −40°C to +125°C, Note 1)L A ..
MC33375ST-2.5T3 ,300mA, 5V, Low Dropout Voltage Regulator with On/Off Control2MC33375DEFINITIONSLoad Regulation − The change in output voltage for a difference between the inpu ..
MC33375ST-5.0T3 ,300mA, 5V, Low Dropout Voltage Regulator with On/Off ControlBlock Diagram2 7Gnd GndALYW3 6V Vin out375xxGnd Gnd4 5ON/OFF N/CThermal &Anti-satPins 4 and 5 Not C ..
MC33375ST-5.0T3 ,300mA, 5V, Low Dropout Voltage Regulator with On/Off Control3OUTPUT VOLTAGE CHANGE (mV) OUTPUT VOLTAGE CHANGE (V)OUTPUT VOLTAGE CHANGE (mV) OUTPUT VOLTAGE CHAN ..
MC33375ST-5.0T3G , 300 mA, Low Dropout Voltage Regulator with On/Off Control
MC10137L-MC10137P
Universal Decade Counter
STATE DIAGRAMS 7 6 512 2 3 4 2 3 4 7 6 512
COUNT UP
COUNT DOWN
SEMICONDUCTOR TECHNICAL DATA -
The MC10137 is a high speed synchronous counter that can count up, down,
preset, or stop count at frequencies exceeding 100 MHz. The flexibility of this
device allows the designer to use one basic counter for most applications. The
synchronous count feature makes the MC10137 suitable for either computers
or instrumentation.
Three control lines (S1, S2, and Carry In) determine the operation mode of
the counter. Lines S1 and S2 determine one of four operations; preset
(program), increment (count up), decrement (count down), or hold (stop count).
Note that in the preset mode a clock pulse is necessary to load the counter, and
the information present on the data inputs (D0, D1, D2, and D3) will be entered
into the counter. Carry Out goes low on the terminal count. The Carry Out on the
MC10137 is partially decoded from Q1 and Q2 directly, so in the preset mode
the condition of the Carry Out after the Clock’s positive excursion will depend on
the condition of Q1 and/or Q2. The counter changes state only on the positive
going edge of the clock. Any other input may change at any time except during
the positive transition of the clock. The sequence for counting out of improper
states is as shown in the State Diagrams. = 625 mW typ/pkg (No Load)
fcount= 150 MHz typ
tpd = 3.3 ns typ (C–Q)
= 7.0 ns typ (C–Cout)
= 5.0 ns typ (Cin–Cout)
FUNCTION SELECT TABLE
PIN ASSIGNMENTVCC1
COUT
VEE
VCC2
CIN