MAX4506CSA ,Fault-Protected / High-Voltage Signal-Line ProtectorsFeaturesThe MAX4506/MAX4507 multiple, two-terminal signal-line' Overvoltage Protectionprotectors ar ..
MAX4506CSA+ ,Fault-Protected, High-Voltage Signal-Line ProtectorsMAX4506/MAX450719-1415; Rev 2; 2/03Fault-Protected, High-Voltage Signal-Line Protectors
MAX4506ESA+ ,Fault-Protected, High-Voltage Signal-Line ProtectorsFeaturesThe MAX4506/MAX4507 multiple, two-terminal signal-line♦ Overvoltage Protectionprotectors ar ..
MAX4507CAP ,Fault-protected, high-voltage, signal-line protectorFeaturesThe MAX4506/MAX4507 multiple, two-terminal signal-line' Overvoltage Protectionprotectors ar ..
MAX4507CAP+T ,Fault-Protected, High-Voltage Signal-Line ProtectorsELECTRICAL CHARACTERISTICS(V+ = +15V, V- = -15V, T = T to T , unless otherwise noted. Typical value ..
MAX4507EAP ,Fault-Protected, High-Voltage Signal-Line ProtectorsFeaturesThe MAX4506/MAX4507 multiple, two-terminal signal-line' Overvoltage Protectionprotectors ar ..
MAX8532EBTJ-T ,Low-Noise, Low-Dropout, 200mA Linear Regulator in UCSPApplicationsOUT PIN-PART TEMP RANGECellular and Cordless Phones VOLTAGE PACKAGEPDAs and Palmtop Com ..
MAX8533EUB ,Smallest, Most Reliable, 12V, InfiniBand-Compliant Hot-Swap ControllerELECTRICAL CHARACTERISTICS(V = +12V, V = 0, T = 0°°C to +85°°C, unless otherwise noted. Typical val ..
MAX8535AEUA ,ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power SuppliesApplications3.3V/5V +V -VO O(MAX8536),Silver Box Supplies for Servers 12V(MAX8535)OUT+On-Board Redu ..
MAX8535AEUA ,ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power SuppliesFeaturesCritical loads often employ parallel-connected power♦ Simple, Integrated, and Inexpensive O ..
MAX8535AEUA ,ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power SuppliesELECTRICAL CHARACTERISTICS(V = 12V (MAX8535/MAX8535A/MAX8585), V = 5V (MAX8536), V = V - 0.1V, R = ..
MAX8535EUA ,ORing MOSFET Controllers with Fastest Fault Isolation for Redundant Power SuppliesFeaturesCritical loads often employ parallel-connected power♦ Simple, Integrated, and Inexpensive O ..
MAX4506CPA-MAX4506CSA
Fault-Protected / High-Voltage Signal-Line Protectors
General DescriptionThe MAX4506/MAX4507 multiple, two-terminal signal-line
protectors are pin-compatible with the industry-standard
MAX366/MAX367. These new circuit protectors feature
fault-protected inputs and Rail-to-Rail®signal handling
capability. The input pins are protected from overvoltage
faults up to ±36V with power on or ±40V with power off.
During a fault condition, the input terminal becomes an
open circuit and only nanoamperes of leakage current
flow from the source; but the switch output (OUT_) fur-
nishes typically 19mA from the appropriate polarity sup-
ply to the load. This ensures unambiguous rail-to-rail
outputs when a fault begins and ends.
The MAX4506 contains three independent protectors
while the MAX4507 contains eight independent protec-
tors. They can protect both unipolar and bipolar analog
signals using either unipolar (+9V to +36V) or bipolar
(±8V to ±18V) power supplies.
These devices have no logic control inputs; the protec-
tors are designed to be always-on when the supplies
are on. On-resistance is 100Wmax and matched within, and on-leakage is less than 0.5nA at TA= +25°C.
The MAX4506 is available in 8-pin SO/DIP packages.
The MAX4507 is available in 20-pin SSOP and 18-pin
SO/DIP packages.
ApplicationsProcess-Control Systems
Hot-Insertion Boards/Systems
Data-Acquisition Systems
Redundant/Backup Systems
ATE Equipment
Sensitive Instruments
FeaturesOvervoltage Protection
±40V with Power Off
±36V with Power OnOpen Signal Paths with Power Off Output Clamps to Either Rail with an Input
OvervoltageAny On Channel Output is Not Affected
by an Overvoltage to Any Other Channel100Wmax On-Resistance10ns Overvoltage Turn-On Delay No Latchup During Power SequencingRail-to-Rail Signal Handling500WOutput Clamp Resistance During
Overvoltage
MAX4506/MAX4507
Fault-Protected, High-Voltage
Signal-Line Protectors
Typical Operating Circuit19-1415; Rev 1; 8/99
Pin Configurations
Ordering Information
MAX4506/MAX4507
Fault-Protected, High-Voltage
Signal-Line Protectors
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS(V+ = +15V, V- = -15V, TA= TMINto TMAX, unless otherwise noted. Typical values are at TA= +25°C.) (Note 3)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
(Voltages Referenced to GND)........................................................................-0.3V to +44.0V
V-.........................................................................-44.0V to +0.3V
V+ to V-................................................................-0.3V to +44.0V
IN_ or OUT_.........................................................................±44V
IN_ Overvoltage with Power On...........................................±36V
IN_ Overvoltage with Power Off...........................................±40V
Continuous Current into Any Terminal..............................±30mA
Peak Current into Any Terminal
(pulsed at 1ms, 10% duty cycle).................................±70mA
Continuous Power Dissipation (TA= +70°C)
8-Pin Narrow SO (derate 5.88mW/°C above +70°C)....471mW
8-Pin Plastic DIP (derate 9.09mW/°C above +70°C).....727mW
8-Pin CERDIP (derate 8.00mW/°C above +70°C)...........640mW
18-Pin Wide SO (derate 9.52mW/ °C above +70°C).......762mW
18-Pin Plastic DIP (derate 11.11mW/ °C above +70°C)...889mW
18-Pin CERDIP (derate 10.53mW/ °C above +70°C)......842mW
20-Pin SSOP (derate 11.11mW/°C above +70°C)...........640mW
Operating Temperature Ranges
MAX4506C_A /MAX4607C_ _.............................0°C to +70°C
MAX4506E_A/MAX4607E_ _...........................-40°C to +85°C
MAX4506MJA/MAX4607MJN........................-55°C to +125°C
Storage Temperature Range.............................-65°C to +160°C
Lead Temperature (soldering, 10sec).............................+300°C
RECOMMENDED OPERATING GUIDELINESV+ to GND..............................................................-0.3V to +40V
V- to GND...............................................................-32V to +0.3V
V+ to V-..................................................................................40V
IN_........................................................................................±40V
OUT_...............................................................................V+ to V-
IN_ to OUT_..........................................................40V Differential
Continuous Current into Any Terminal..............................≤30mA
Peak Current into Any Terminal
(pulsed at 1ms, 10% duty cycle).................................≤70mA
Note 1: OUT_ pins are not fault protected. Signals on OUT_ exceeding V+ or V- are clamped by internal diodes. Limit forward-diodecurrent to maximum current rating.
Note 2: IN_ pins are fault protected. Signals on IN_ exceeding -36V to +36V may damage the device. These limits apply with powerapplied to V+ or V-, or ±40V with V+ = V- = 0.
MAX4506/MAX4507
Fault-Protected, High-Voltage
Signal-Line Protectors
ELECTRICAL CHARACTERISTICS—Single Supply(V+ = +12V, V- = -0V, TA= TMINto TMAX, unless otherwise noted. Typical values are at TA= +25°C.) (Note 3)
ELECTRICAL CHARACTERISTICS —Dual Supplies (continued)(V+ = +15V, V- = -15V, TA= TMINto TMAX, unless otherwise noted. Typical values are at TA = +25°C.) (Note 3)
MAX4506/MAX4507
Fault-Protected, High-Voltage
Signal-Line Protectors
ELECTRICAL CHARACTERISTICS—Single Supply (continued)(V+ = +12V, V- = -0V, TA= TMINto TMAX, unless otherwise noted. Typical values are at TA= +25°C.) (Note 3)
Note 3:The algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 4:See Fault-Free Analog Signal Range vs. Supply Voltages graph in the Typical Operating Characteristics.
Note 5:Guaranteed by design.
Note 6:ΔRON= RON(MAX)- RON(MIN)
Note 7:Leakage parameters are 100% tested at maximum rated hot temperature and guaranteed by correlation at TA= +25°C.
Note 8:Leakage testing for single-supply operation is guaranteed by testing with dual supplies.
Note 9:Guaranteed by testing with dual supplies.
MAX4506/MAX4507
Fault-Protected, High-Voltage
Signal-Line Protectors
Typical Operating Characteristics(TA = +25°C, unless otherwise noted.)
MAX4506/MAX4507
Fault-Protected, High-Voltage
Signal-Line Protectors