IC Phoenix
 
Home ›  LL19 > LH1512AB,High Voltage Optically Coupled Solid ...
LH1512AB Fast Delivery,Good Price
Part Number:
If you need More Quantity or Better Price,Welcom Any inquiry.
We available via phone +865332716050 Email
Partno Mfg Dc Qty AvailableDescript
LH1512ABinfineonN/a154avaiHigh Voltage Optically Coupled Solid ...


LH1512AB ,High Voltage Optically Coupled Solid ... 6G41.53SSR hiVolt copy Page 41 Monday, ..
LH1512BACTR ,Dual 1 Form A/B, C Solid State RelayAbsolute Maximum Ratings can cause permanent 150damage to the device. These are absolute stress rat ..
LH1513AB ,2 Form A Solid State RelayRevision 17-August-01 3–69LED Forward Current for SwitchChange in ON-resistance (%)LED Forward Volt ..
LH1514AAC ,2 Form A Solid State RelayFunctional Description Figure 11. Pin Diagram and Pin OutsFigure 12 shows the switch characteristic ..
LH1514AAC ,2 Form A Solid State RelayAbsolute Maximum Ratings can cause permanent Parameter Sym. Min. Typ. Max. Unitdamage to the device ..
LH1514AAC ,2 Form A Solid State RelayAPPLICATIONS .268 (6.81).255 (6.48)• Protection Switching (T1 sparing)– Digital Access Cross Connec ..
LM2904ITP ,Low Power Dual Operational AmplifierElectrical Characteristics+V = +5.0V, unless otherwise statedParameter Conditions LM158A LM358A LM1 ..
LM2904M ,Dual Operational AmplifierLM2904,LM358/LM358A,LM258/LM258ADual Operational Amplifier
LM2904M/NOPB ,Low Power Dual Operational Amplifier 8-SOIC -40 to 85Features 3 DescriptionThe LM158 series consists of two independent, high1• Available in 8-Bump DSBG ..
LM2904MX ,Dual Operational AmplifierFeaturesblocks and all the conventional op amp circuits which nown Available in 8-Bump micro SMD ch ..
LM2904MX/NOPB ,Low Power Dual Operational Amplifier 8-SOIC -40 to 85 SNOSBT3I–JANUARY 2000–REVISED DECEMBER 20145 Pin Configuration and FunctionsD, P, and NAB Package8 ..
LM2904N ,Dual Operational AmplifierOrder this document by LM358/D * ** ** ** *DUAL DIFFERENTIAL INPUTUtilizing the circuit designs pe ..


LH1512AB
High Voltage Optically Coupled Solid ...
6G–41
Absolute Maximum Ratings

=25
Stresses in excess of the Absolute Maximum Ratings
can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the
device is not implied at these or any other conditions in
excess of those given in the operational sections of this
document. Exposure to Absolute Maximum Ratings for
extended periods of time can adversely affect reliability.
6G–42
Electrical Characteristics

=25
Minimum and maximum values are testing require-
ments. Typical values are characteristics of the device
and are the result of engineering evaluations. Typical
values are for information purposes only and are not
part of the testing requirements.I
=10 mA.
6G–43
A. LED Voltage vs. Temperature
C. LED Current for Switch Turn-Off vs. Temperature
E. Switch Capacitance vs. Applied Voltage
B. LED Dropout Voltage vs. Temperature
D. ON-Resistance vs. Temperature
F. Output Isolation

AMBIENT TEMPERATURE (°C)
LED FORWARD VOLTAGE (V)
AMBIENT TEMPERATURE (°C)
LED FORWARD CURRENT FOR SWITCH
TURN-OFF (%) NORMALIZED TO 25 2040
APPLIED VOLTAGE (V)
CAPACITANCE (pF)
CHANGE IN ON-RESISTANCE (%)
NORMALIZED TO 25
AMBIENT TEMPERATURE (°C)
6G–44
A. Insertion Loss vs. Frequency
C. Leakage Current vs. Applied Voltage @ 50

E. Leakage Current vs. Applied Voltage @ 85

B. Leakage Current vs. Applied Voltage @ 25

D. Leakage Current vs. Applied Voltage @ 70

F. Switch Breakdown Voltage vs. Temperature

FREQUENCY (Hz)
INSERTION LOSS (dB)
LOAD VOLTAGE (V)
OFF-STATE LEAKAGE CURRENT (nA)
LOAD VOLTAGE (V)
OFF-STATE LEAKAGE CURRENT (nA)
LOAD VOLTAGE (V)
OFF-STATE LEAKAGE CURRENT (nA)
AMBIENT TEMPERATURE (°C)
CHANGE IN BREAKDOWN VOLTAGE (%)
NORMALIZED TO 25
6G–45
A. Switch Offset Voltage vs. Temperature
C. Turn-On Time vs. LED Current
B. Turn-On/Off Time vs. Temperature
D. Turn-Off Time vs. LED Current
40
AMBIENT TEMPERATURE (°C)
SWITCH OFFSET VOLTAGE (µV)
LED FORWARD CURRENT (mA)
TURN-ON TIME (ms)
AMBIENT TEMPERATURE (°C)
CHANGE IN TURN-ON/OFF TIME (%)
NORMALIZED TO 25 50
LED FORWARD CURRENT (mA)
TURN-OFF TIME (ms)40
6G–46
Absolute Maximum Ratings

=25
Stresses in excess of the Absolute Maximum Ratings
can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the
device is not implied at these or any other conditions in
excess of those given in the operational sections of this
document. Exposure to Absolute Maximum Ratings for
extended periods of time can adversely affect reliability.
Recommended Operating Conditions

AMBIENT TEMPERATURE (°C)
LOAD CURRENT (mA)
AMBIENT TEMPERATURE (°C)
LOAD CURRENT (mA)
AMBIENT TEMPERATURE (°C)
LOAD CURRENT (mA)
150
6G–47
Electrical Characteristics

=25
Minimum and maximum values are testing require-
ments. Typical values are characteristics of the device
and are the result of engineering evaluations. Typical
values are for information purposes only and are not
part of the testing requirement.
ic,good price


TEL:86-533-2716050      FAX:86-533-2716790
   

©2020 IC PHOENIX CO.,LIMITED