KA2803BD ,Earth Leakage DetectorFeatures Description• Low Power Consumption P =5mW, 100V/200V The KA2803B is designed for use in ea ..
KA2804 , LINEAR INTEGRATED CIRCUIT
KA2807 ,Earth Leakage DetectorKA2807Earth Leakage Detector
KA2807DTF ,Earth Leakage DetectorFeatures Description• Full Advantage of the UL943 The KA2807 is a IC for ground fault circuit inter ..
KA2811C ,12V Spindle Motor and Voice Coil Motor DriverFeatures DescriptionThe KA2811C is a monolithic one-chip IC which includes SMP CircuitSPM (Spindle ..
KA2821D ,The KA2821D is a monolithic integrated circuit, and suit able as a two-phase stepping motor driver of a 3.5-inch FDD systemKA2821DStepping Motor Driver
KQ0805TTER10K , high Q inductor
KRA101M , EPITAXIAL PLANAR PNP TRANSISTOR (SWITCHING, INTERFACE CIRCUIT AND DRIVER CIRCUIT)
KRA101-M , EPITAXIAL PLANAR PNP TRANSISTOR (SWITCHING, INTERFACE CIRCUIT AND DRIVER CIRCUIT)
KRA103M , EPITAXIAL PLANAR PNP TRANSISTOR (SWITCHING, INTERFACE CIRCUIT AND DRIVER CIRCUIT)
KRA103-M , EPITAXIAL PLANAR PNP TRANSISTOR (SWITCHING, INTERFACE CIRCUIT AND DRIVER CIRCUIT)
KRA104M , EPITAXIAL PLANAR PNP TRANSISTOR (SWITCHING, INTERFACE CIRCUIT AND DRIVER CIRCUIT)
KA2803BD
Earth Leakage Detector
Features Low Power Consumption PD =5mW, 100V/200V Built-in Voltage Regulator High Gain Differential Amplifier 0.4mA Output Current Pulse to Trigger SCR' S Low External Part Count DIP Package (8-DIP), High Packing Density High Noise Immunity, Large Surge Margin Super Temperature Characteristic of Input Sensitivity Wide Operating Temperature Range (TA = -25°C ~
+80°C) Operation from 12 to 20V Input
Functions Differential Amplifier Level Comparator Latch Circuit
DescriptionThe KA2803B is designed for use in earth leakage circuit
interrupters, for stable operation of the AC line in breakers.
The input of the differential amplifier is connected to the
secondary coil of ZCT(Zero Current Transformer). The
amplified output of differential amplifier is integrated at
external capacitor to gain adequate time delay that is
specified in KSC4613. The level comparator generates high
level when earth leakage current is greater than the fixed
level.