HFA140NJ60C ,600V 140A HEXFRED Common Cathode Diode in a TO-244AB Non-Isolated packageapplications whereswitching losses are significant portion of the total losses.TO-244ABAbsolute Max ..
HFA15PB60 ,600V 15A HEXFRED Discrete Diode in a TO-247 (2 LEAD) packageFeatures• Ultrafast Recovery V (typ.)* = 1.3VF4• Ultrasoft RecoveryI = 15AF(AV)• Very Low IRRMQ (ty ..
HFA15TB60 ,600V 15A HEXFRED Discrete Diode in a TO-220AC packageFeaturesV = 600VR• Ultrafast Recovery• Ultrasoft RecoveryV = 1.7VF• Very Low IRRM• Very Low Qrr ..
HFA15TB60PBF ,600V 15A UltraFast Recovery Diode packaged in TO-220AC packageapplications in power supplies and power con-version systems (such as inverters), motor drives, and ..
HFA15TB60PBF ,600V 15A UltraFast Recovery Diode packaged in TO-220AC package HFA15TB60PbF Ultrafast, Soft Recovery Diode Ultrafast Recovery V = 600V R Ultrasoft Recovery ..
HFA15TB60S ,600V 15A HEXFRED Discrete Diode in a D2-Pak (HEXFRED) packageFeaturesBaseV = 600VR• Ultrafast RecoveryCathode2• Ultrasoft RecoveryV = 1.7VF• Very Low IRRM• Ve ..
HM62V16256CLTT-7 , 4 M SRAM (256-kword x 16-bit)
HM62V16256CLTT-7SL , 4 M SRAM (256-kword x 16-bit)
HM62V8512BLFP-7 , 4 M SRAM (512-kword x 8-bit)
HM62V8512BLFP-7 , 4 M SRAM (512-kword x 8-bit)
HM62V8512BLFP-7SL , 4 M SRAM (512-kword x 8-bit)
HM62V8512BLTT-7 , 4 M SRAM (512-kword x 8-bit)
HFA140NJ60C
600V 140A HEXFRED Common Cathode Diode in a TO-244AB Non-Isolated package
International
TOR Rectifier
PD -2.458 rev. B 02/99
HFA14ONJ6OC
HEXFRED"'
Featu res
. Reduced RFI and EMI
. Reduced Snubbing
. Extensive Characterization of
Recovery Parameters
Description
Ultrafast, Soft Recovery Diode
LUG LUG
TERMINAL TERMINAL
ANODE 1 ANODE 2
BASE COM MON CATHODE
VR = 600V
VF(typ.)® =1.2V
|F(AV) = 140A
er (typ.) = 340nC
IRRM(typ.) = 8.5A
trr(typ.) = 33ns
ditec)M/tit (typ.)o = 220A/ps
HEXFRED"" diodes are optimized to reduce losses and EMl/RFI in high frequency
power conditioning systems.
An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications.
ideally suited for power converters, motors drives and other applications where
switching losses are significant portion of the total losses.
These devices are
T0-244AB
Absolute Maximum Ratings (per Leg)
Parameter Max. Units
VR Cathode-to-Anode Voltage 600 V
IF @ Tc = 25°C Continuous Forward Current 126
IF @ To = 100°C Continuous Forward Current 63 A
IFSM Single Pulse Forward Current LO 400
EAs Non-Repetitive Avalanche Energy © 220 pd
PD @ Tc = 25°C Maximum Power Dissipation 310 W
PD @ Tc = 100°C Maximum Power Dissipation 125
To Operating Junction and
TSTG Storage Temperature Range -55 to +150 C
Thermal - Mechanical Characteristics
Parameter Min. Typ. Max. Units
Rm Junction-to-Case, Single Leg Conducting - - 0.40 "C/W
Junction-to-Case, Both Legs Conducting - - 0.20 K/W
Rmcs Case-to-Sink, Flat, Greased Surface - 0.10 -
Wt Weight - 79 (2.8) - g (oz)
Mounting Torque GD 30 (3.4) - 40 (4.6) .
Mounting Torque Center Hole 12 (1.4) - 18 (2.1) b11n,
TerminalTorque 30 (3.4) - 40 (4.6) ( m)
Vertical Pull - - 80 lbf-in
2 inch Lever Pull - - 35
Note: (D Limited by junction temperature
© L = 100pH, duty cycle limited by max TJ
© 125°C
© Mounting surface must be smooth, flat, free or burrs or other
protrusions, Apply a thin even film or thermal grease to mounting
surface. Gradually tighten each mounting bolt in 5-10 Ibf-in steps
until desired or maximum torque limits are reached. Module
HFA140NJ60C
PD-2.458 rev. B 02/99
International
TOR Rectifier
Electrical Characteristics (per Leg) @ Tu = 25°C (unless otherwise specified)
Parameter Min. Typ. Max. Units Test Conditions
VBR Cathode Anode Breakdown Voltage 600 - - V IR = 100PA
VFM Max Forward Voltage - 1.3 1.5 IF = 70A
- 1.5 1.7 V IF =140A See Fig.1
- 1.2 1.4 |F=70A,TJ= 125°C
IRM Max Reverse Leakage Current - 4.0 20 PA VR = VR Rated .
- 1.0 4.0 mA To =125''C,VR = 480V See Fig. 2
CT Junction Capacitance - 140 250 pF VR = 200V See Fig. 3
From top of terminal hole to mounting
Ls Series Inductance - 7.0 - nH plane
Dynamic Recovery Characteristics (per Leg) @ To = 25°C (unless otherwise specified)
90.17 (3.550)
Parameter Min. Typ. Max. Units Test Conditions
trr Reverse Recovery Time - 33 - IF = 1.0A, dir/dt = 200A/ps, VR = 30V
tm - 80 120 ns To=25''C
t”2 - 140 220 To=125''C b-- 70A
IRRM1 Peak Recovery Current - 8.5 15 A To = 25''C
IRRM2 - 14 25 To=125''C VR = 200V
Qm Reverse Recovery Charge - 340 900 nC To=25''C
er2 - 980 2300 To=125''C dif/dt=200A/ps
tftrec)M/dtl Peak Rate of Fall of Recovery Current - 300 - Al s To = 25°C
tftrec)M/tit2 Duringtb - 220 - p T J= 125°C
80.01 (3.150) 10.41 (0.410)
-- 40.26_(1.585) - 9.65 (0.380) DIA.
39.75 (1.565) ,
"s, r ,
_ 20.32 (0.800)
, 1 (ii) (tttii)) J (l) 17.78(0.700)
I LEAD ASSIGN MENTS
7.49 (0.295) DIA / 1-ANODE
6.99(0.275) . - 34.925 (1.375 - - 4.95 (0.195) 2-CATHODE
(2 PLCS.) REF. 4.70 (0.185) DIA. 3-ANODE
63.50 (2.500)
60.96 (2.400) -1/4-20 SLOTTED HEX
23 55 (0 927) mm TPY" l
2of42 (0.1304) 1 I li75fi20l CONFORMS TO JEDEC
J I I ' I 14-99 (0.590) 0UTLINETO-244AB
I I I I , Dimensions in Millimeters and (Inches)
3.35 (0.132)
l 92.71 (3.650) l 3.02 (0.119)