IC Phoenix logo

Home ›  D  › D30 > DS2762K

DS2762K from MAXIM,MAXIM - Dallas Semiconductor

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

DS2762K

Manufacturer: MAXIM

Li+battery monitor evaluation kit

Partnumber Manufacturer Quantity Availability
DS2762K MAXIM 1500 In Stock

Description and Introduction

Li+battery monitor evaluation kit The DS2762K is a battery monitor and protector manufactured by Maxim Integrated (now part of Analog Devices). Here are its key specifications:

1. **Functionality**: Monitors voltage, current, temperature, and remaining capacity in Li-ion or Li-polymer battery packs.
2. **Current Measurement**: Integrated 25mΩ sense resistor for high-side current sensing.
3. **Voltage Measurement**: 12-bit resolution, ±15mV accuracy.
4. **Current Measurement**: 12-bit resolution, ±7.5% accuracy.
5. **Temperature Measurement**: 9-bit resolution, ±2°C accuracy.
6. **Capacity Estimation**: Coulomb counter with automatic offset correction.
7. **Communication Interface**: 1-Wire interface for data communication.
8. **Protection Features**: Overvoltage, undervoltage, overcurrent, and overtemperature protection.
9. **Operating Voltage Range**: 2.5V to 4.5V.
10. **Package**: 16-pin TSSOP (DS2762K variant).
11. **Applications**: Portable electronics, smartphones, tablets, and other battery-powered devices.

For detailed specifications, refer to the official datasheet from Maxim Integrated (Analog Devices).

Application Scenarios & Design Considerations

Li+battery monitor evaluation kit# DS2762K High-Precision Battery Monitor and Protector

*Manufacturer: MAXIM*

## 1. Application Scenarios

### Typical Use Cases
The DS2762K serves as a comprehensive battery management solution in various portable and battery-powered applications:

 Primary Applications: 
-  Portable Medical Devices : Insulin pumps, portable oxygen concentrators, and patient monitoring equipment where accurate battery state-of-charge (SOC) monitoring is critical for patient safety
-  Professional Test Equipment : Handheld oscilloscopes, multimeters, and data loggers requiring precise battery runtime prediction
-  Industrial PDAs and Mobile Computers : Barcode scanners, inventory management devices operating in demanding environments
-  Emergency Backup Systems : UPS devices and emergency lighting systems requiring reliable battery health monitoring

### Industry Applications
-  Consumer Electronics : High-end digital cameras, premium portable audio equipment, and professional-grade power tools
-  Telecommunications : Wireless routers, base station backup power systems, and portable communication devices
-  Automotive : Aftermarket car audio systems, GPS tracking devices, and emergency vehicle equipment
-  Military/Aerospace : Portable field equipment and backup power systems for critical applications

### Practical Advantages and Limitations

 Advantages: 
-  High Accuracy : ±1% SOC accuracy under controlled conditions with proper calibration
-  Integrated Protection : Built-in overcurrent, short-circuit, and over/under-voltage protection
-  Low Power Consumption : 55μA active current, 2μA sleep mode for extended battery life
-  Comprehensive Monitoring : Simultaneous voltage, current, and temperature measurement
-  Non-volatile Memory : 32 bytes of EEPROM for parameter storage and calibration data

 Limitations: 
-  Calibration Dependency : Requires initial calibration for optimal accuracy
-  Temperature Sensitivity : SOC accuracy degrades at temperature extremes without compensation
-  Limited Current Range : Maximum ±500mV sense voltage limits high-current applications
-  Complex Implementation : Requires sophisticated firmware for full feature utilization

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Incurrent Sense Resistor Selection 
-  Problem : Using incorrect sense resistor values leading to measurement inaccuracies
-  Solution : Select 10mΩ-50mΩ precision resistors with ±1% tolerance and low temperature coefficient

 Pitfall 2: Poor Thermal Management 
-  Problem : Temperature measurement errors due to improper thermal coupling
-  Solution : Place device close to battery cells and use thermal vias for improved heat transfer

 Pitfall 3: Inadequate PCB Layout 
-  Problem : Noise interference affecting current measurement accuracy
-  Solution : Implement star grounding and separate analog/digital power domains

### Compatibility Issues

 Microcontroller Interface: 
-  1-Wire Protocol : Compatible with most modern microcontrollers but requires precise timing
-  Voltage Levels : 2.7V to 5.5V operation range matches most 3.3V and 5V systems
-  Communication Distance : Limited to ~3 meters without bus extenders

 Battery Chemistry Compatibility: 
-  Li-ion/Li-polymer : Primary design target with optimal performance
-  NiMH/NiCd : Functional but requires custom SOC algorithms
-  Lead-Acid : Limited compatibility due to different voltage characteristics

### PCB Layout Recommendations

 Critical Layout Guidelines: 
1.  Sense Resistor Placement 
   - Position sense resistor close to battery negative terminal
   - Use Kelvin connections for accurate voltage measurement
   - Maintain symmetrical routing from sense resistor to IC

2.  Power Distribution 
   - Use separate power planes for analog and digital sections
   - Implement 0.1μF decoupling capacitors within 5mm of VDD pin
   - Route battery connections with adequate trace width (≥20mil for 2A

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips