BTS428-L2 ,Smart High Side SwitchesBlock Diagram Protection Functions Vbb• Short circuit protection • Overload protection • Current l ..
BTS432D2 ,Smart Highside Power SwitchGeneral DescriptionN channel vertical power FET with charge pump, ground referenced CMOS compatible ..
BTS432E2 ,Smart Highside Power SwitchGeneral Description N channel vertical power FET with charge pump, ground referenced CMOS compatibl ..
BTS432E2 E3062A ,Smart Highside Power SwitchFeatures V 80 V 1 Load dump• ) Load dump and reverse battery protection V -V Avalanche Clamp 58 V ..
BTS432E2. ,Smart Highside Power SwitchCharacteristics Parameter and Conditions Symbol Values Unitat Tj = 25 °C, V = 12 V unless otherwis ..
BTS432F2 ,Smart Highside Power SwitchGeneral DescriptionN channel vertical power FET with charge pump, ground referenced CMOS compatible ..
BZX84C4V7T-7-F , 150mW SURFACE MOUNT ZENER DIODE
BZX84C5.1V ,Small Signal Zener DiodesRev. 1.7, 14-Jul-05 3BZX84-V-SeriesVishay SemiconductorsTypical Characteristics (Tamb = 25 °C unles ..
BZX84C5.6V ,Small Signal Zener DiodesThermal CharacteristicsT = 25 °C, unless otherwise specifiedambParameter Test condition Symbol Valu ..
BZX84C51 ,SMD Zener Diode Single: StandardAbsolute Maximum RatingsT = 25
BTS428-L2
Smart High Side Switches
PROFET® BTS428L2 Smart High-Side Power Switch
One Channel: 60mΩ
Status Feedback
Product Summary Package
General Description N channel vertical power MOSFET with charge pump, ground referenced CMOS compatible input and
diagnostic feedback, monolithically integrated in Smart SIPMOS technology. Providing embedded protective functions
Applications µC compatible high-side power switch with diagnostic feedback for 5V, 12V and 24V grounded loads All types of resistive, inductive and capacitve loads Most suitable for loads with high inrush currents, so as lamps Replaces electromechanical relays, fuses and discrete circuits
Basic Functions Very low standby current CMOS compatible input Improved electromagnetic compatibility (EMC) Fast demagnetization of inductive loads Stable behaviour at undervoltage Wide operating voltage range Logic ground independent from load ground
Protection Functions Short circuit protection Overload protection
• Current limitation
• Thermal shutdown Overvoltage protection (including load dump) with external
resistor Reverse battery protection with external resistor Loss of ground and loss of Vbb protection Electrostatic discharge protection (ESD)
Diagnostic Function Diagnostic feedback with open drain output Open load detection in ON-state Feedback of thermal shutdown in ON-state
Block Diagram
BTS428L2
Functional diagram
Pin Definitions and Functions BTS428L2
Maximum Ratings at Tj = 25 °C unless otherwise specified
Thermal Characteristics 1) Supply voltages higher than Vbb(AZ) require an external current limit for the GND and status pins (a 150Ω
resistor for the GND connection is recommended). 2) RI = internal resistance of the load dump test pulse generator 3) VLoad dump is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839 4) EAS is the maximum inductive switch-off energy 5) Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm2 (one layer, 70µm thick) copper area for Vbb
connection. PCB is vertical without blown air.
BTS428L2
Electrical Characteristics
Load Switching Capabilities and Characteristics
Operating Parameters 6) not subject to production test, specified by design 7) Supply voltages higher than Vbb(AZ) require an external current limit for the GND and status pins (a 150Ω
resistor for the GND connection is recommended. See also VON(CL) in table of protection functions and
circuit diagram page 8. 8) Measured with load 9) Add IST, if IST > 0, add IIN, if VIN>5.5 V
BTS428L2
Protection Functions10)
Diagnostic Characteristics 10) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not designed for continuous repetitive operation. 11) Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm2 (one layer, 70µm thick) copper area for Vbb
connection. PCB is vertical without blown air.
12) Requires 150 Ω resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see max. ratings page 3 and circuit page 8).
BTS428L2
Input and Status Feedback14) 14) If a ground resistor RGND is used, add the voltage drop across this resistor.
BTS428L2
Truth Table L = "Low" Level X = don't care Z = high impedance, potential depends on external circuit H = "High" Level Status signal after the time delay shown in the diagrams (see fig 5. page 12)