IC Phoenix logo

Home ›  S  › S92 > SSRP105B1

SSRP105B1 from ST,ST Microelectronics

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

SSRP105B1

Manufacturer: ST

DUAL ASYMMETRICAL OVERVOLTAGE PROTECTION FOR TELECOM LINE

Partnumber Manufacturer Quantity Availability
SSRP105B1 ST 6882 In Stock

Description and Introduction

DUAL ASYMMETRICAL OVERVOLTAGE PROTECTION FOR TELECOM LINE FEATURESn Dual bi-directional asymmetrical protectionTIP 1 8 GNDStand-off voltages:l Between Line and GroundNCGND2 7+105V for positive voltages-180V for negative voltagesNC3l Between Line and Line GND6+180V for positive voltages-180V for negative voltages 4RING 5 GNDn Peak pulse current: I = 50A (5/310μs)PPn Holding current:l I = 100mAH+l I = 150mAH-COMPLY WITH THE FOLLOWING STANDARDSRequired Min. serialPeak Surge Voltage CurrentPeak resistor to meetVoltage Waveform Waveformcurrent standards(V) (μs) (μs)(A) (Ω)ITU-T K20 / K211500 10/700 5/310 38 -VDE04332000 10/700 5/310 50 -IEC61000-4-5Level 3 10/700 5/310 50 -Level 4 1.2/50 8/20 100 -FCC Part 681500 10/160 10/160 200 18800 10/560 10/560 100 10BELLCORE2500 2/10 2/10 500 10GR1089 First level1000 10/1000 10/1000 100 19TM: ASD is trademarks of STMicroelectronics.1/6October 2002 - Ed: 1ASSRP105B1APPLICATION INFORMATIONFig. 1: Topology of the classical line card protection. Fig. 2: Classical use of the SSRP105B1.RPTCTIPPTCRTIP2ndSLIC1ststageLINEstageR(*)PTCSLICRINGPTCRRING±VRINGSSRP105B1VRINGBAT(*) SLIC with integrated ring generator or Solid-State RelayRing generatorThe classical line card requires protection before the The SSRP105B1 device takes into account thisring relay and a second one for the SLIC (figure 1). fact and is based on asymmetrical voltagecharacteristics (figure 3a). The ring signal beingThe use of new SLICs with integrated ringshifted back by the battery voltage, thegenerator or board based on solid-state ring relayisSSRP105B1 negative breakover value VBO-suppresses this second protection (figure 2).greater than the positive one V . This pointBO+Then, the only remaining stage, located betweenguarantees a protection operation very close to thethe line and the ring relay, has to optimize thepeak of the normal operating voltage without anyprotection.disturbance of the ring signal.The classical symmetrical first stage protectorbecomes not sufficient to avoid any circuitdestruction during surges.Fig. 3: SSRP105B1

Application Scenarios & Design Considerations

DUAL ASYMMETRICAL OVERVOLTAGE PROTECTION FOR TELECOM LINE

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips