IC Phoenix logo

Home ›  D  › D27 > DS1921

DS1921 from DS,MAXIM - Dallas Semiconductor

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

DS1921

Manufacturer: DS

High-Resolution Thermochron iButton

Partnumber Manufacturer Quantity Availability
DS1921 DS 355 In Stock

Description and Introduction

High-Resolution Thermochron iButton The DS1921 is a temperature logger manufactured by Maxim Integrated (now part of Analog Devices).  

### Key Specifications:  
- **Temperature Range**: -40°C to +85°C  
- **Accuracy**: ±1°C from -10°C to +85°C, ±2°C from -40°C to -10°C  
- **Resolution**: 0.5°C  
- **Memory**: 2048 bytes of NV SRAM for temperature logging  
- **Logging Interval**: Programmable from 1 minute to 273 hours  
- **Battery Life**: Up to 10 years (lithium battery-backed)  
- **Interface**: 1-Wire® communication protocol  
- **Unique 64-Bit ID**: Each device has a factory-lasered ROM ID  
- **Housing**: Stainless steel, waterproof (iButton form factor)  
- **Operating Voltage**: 2.8V to 5.25V  

The DS1921 is commonly used for environmental monitoring, cold chain logistics, and industrial temperature logging.  

Let me know if you need additional details.

Application Scenarios & Design Considerations

High-Resolution Thermochron iButton# DS1921 Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The DS1921 is a  high-precision temperature logger  with integrated data storage, primarily employed in  environmental monitoring  and  temperature-sensitive applications . Its compact, battery-powered design enables deployment in diverse scenarios:

-  Cold Chain Monitoring : Tracks temperature variations during pharmaceutical and perishable goods transportation
-  Environmental Data Logging : Records ambient temperature in research studies, HVAC systems, and industrial processes
-  Quality Assurance : Monitors manufacturing processes where temperature control is critical
-  Asset Tracking : Provides temperature history for high-value equipment during transit

### Industry Applications
 Medical & Pharmaceutical 
- Vaccine storage monitoring (-40°C to +85°C range)
- Laboratory equipment temperature validation
- Clinical trial sample integrity assurance

 Food & Beverage 
- Perishable goods transportation monitoring
- Storage facility temperature compliance
- Supply chain quality control

 Industrial & Manufacturing 
- Process control system validation
- Equipment thermal performance monitoring
- Clean room environmental compliance

 Research & Development 
- Field study data collection
- Experimental condition monitoring
- Long-term environmental studies

### Practical Advantages
-  Autonomous Operation : Self-contained logging eliminates need for continuous external power
-  High Accuracy : ±0.5°C typical accuracy across operating range
-  Non-Volatile Memory : 2048 bytes of data storage with 10-year data retention
-  Rugged Construction : Stainless steel housing provides environmental protection
-  Simple Interface : 1-Wire® protocol minimizes connection requirements

### Limitations
-  Fixed Sampling Rate : Limited flexibility in sampling interval configuration
-  Battery Dependency : Non-replaceable battery limits device lifetime (typically 10 years)
-  Data Retrieval : Requires physical connection for data access
-  Memory Capacity : Limited storage may be insufficient for long-duration, high-frequency logging

## 2. Design Considerations

### Common Design Pitfalls and Solutions
 Pitfall 1: Insufficient Pull-up Resistance 
-  Issue : Weak pull-up resistors cause communication failures on 1-Wire bus
-  Solution : Implement 2.2kΩ pull-up resistor close to DS1921 connection point

 Pitfall 2: Power Sequencing Problems 
-  Issue : Simultaneous data and power transitions create bus contention
-  Solution : Implement proper power-up sequencing with 100ms delay before communication

 Pitfall 3: Environmental Exposure 
-  Issue : Condensation affects electrical connections in humid environments
-  Solution : Use conformal coating and ensure proper sealing in enclosure design

 Pitfall 4: Electromagnetic Interference 
-  Issue : Noise on long 1-Wire bus lines causes data corruption
-  Solution : Implement twisted-pair cabling and ferrite beads for noise suppression

### Compatibility Issues
 Microcontroller Interfaces 
-  Compatible : Most microcontrollers with GPIO and UART capabilities
-  Incompatible : Systems without precise timing control for 1-Wire protocol
-  Recommended : Use dedicated 1-Wire master controllers (DS2480B) for complex systems

 Power Supply Considerations 
- Operating voltage range: 2.8V to 5.25V
- Peak current during temperature conversion: 1.5mA
- Quiescent current: 25μA (typical)

 Communication Protocol 
- 1-Wire protocol requires precise timing (15μs to 60μs bit times)
- Compatible with standard UART at 115.2k baud for software implementation
- Multiple devices can share single bus with unique 64-bit ROM IDs

### PCB Layout Recommendations
 Power Distribution 
- Place 100nF decoupling capacitor within 10mm of device
- Use separate ground plane for analog and digital sections

Partnumber Manufacturer Quantity Availability
DS1921 DALLAS 2 In Stock

Description and Introduction

High-Resolution Thermochron iButton The DS1921 is a temperature logger manufactured by Dallas Semiconductor (now part of Maxim Integrated). Here are its key specifications:  

- **Type**: Thermochron iButton  
- **Memory**: 4096 bytes of NV SRAM  
- **Temperature Range**: -40°C to +85°C  
- **Accuracy**: ±1°C from -10°C to +65°C  
- **Resolution**: 0.5°C  
- **Data Logging**: Stores up to 2048 temperature readings  
- **Real-Time Clock**: Integrated for time-stamped logging  
- **Communication**: 1-Wire interface  
- **Power**: Self-powered by a lithium cell (CR2032)  
- **Housing**: Stainless steel, rugged design  
- **Operating Life**: Approximately 10 years (varies with usage)  

This device is designed for temperature monitoring and data logging applications.

Application Scenarios & Design Considerations

High-Resolution Thermochron iButton# DS1921 iButton Temperature Logger Technical Documentation

*Manufacturer: DALLAS (now part of Maxim Integrated)*

## 1. Application Scenarios

### Typical Use Cases
The DS1921 is a rugged, self-contained temperature logger in a compact iButton package that provides sophisticated temperature monitoring capabilities across various environments:

 Environmental Monitoring Applications: 
-  Cold Chain Logistics : Continuous temperature monitoring during transportation of pharmaceuticals, vaccines, and perishable foods
-  HVAC System Validation : Long-term temperature profiling in building management systems
-  Industrial Process Monitoring : Temperature tracking in manufacturing processes and quality control

 Medical and Healthcare Applications: 
-  Sterilization Validation : Monitoring autoclave cycles and sterilization processes
-  Laboratory Equipment : Temperature logging for incubators, refrigerators, and freezers
-  Clinical Trials : Ensuring proper temperature conditions for biological samples

 Industrial and Commercial Applications: 
-  Food Safety Compliance : HACCP monitoring in food processing and storage facilities
-  Electronic Component Testing : Environmental stress screening of electronic assemblies
-  Museum and Archive Preservation : Monitoring environmental conditions for artifact preservation

### Industry Applications

 Pharmaceutical Industry 
- Real-time temperature monitoring during drug manufacturing and distribution
- Compliance with FDA 21 CFR Part 11 requirements for electronic records
- Batch quality assurance through temperature history documentation

 Food and Beverage Industry 
- Supply chain temperature integrity verification
- Regulatory compliance documentation for food safety standards
- Quality control during production and storage processes

 Research and Development 
- Long-term environmental studies and data collection
- Prototype testing under various temperature conditions
- Scientific experiment monitoring and validation

### Practical Advantages and Limitations

 Advantages: 
-  Rugged Construction : Stainless steel package withstands harsh environments
-  Self-Contained Operation : No external power required during data logging
-  High Accuracy : ±1°C temperature accuracy across operating range
-  Large Memory Capacity : 2048 temperature readings with time-stamping
-  Easy Deployment : Simple contact-based interface reduces installation complexity

 Limitations: 
-  Limited Sampling Rate : Maximum sampling interval of 1 minute may be insufficient for rapid temperature changes
-  Contact-Based Interface : Requires physical contact for data retrieval
-  Fixed Memory Size : Cannot expand storage capacity for longer monitoring periods
-  Temperature Range : Limited to -40°C to +85°C operating range

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Insufficient Contact Reliability 
-  Problem : Poor electrical contact leads to communication failures
-  Solution : Implement spring-loaded contacts with adequate normal force (≥150g)
-  Implementation : Use gold-plated contacts and ensure proper alignment mechanisms

 Pitfall 2: Thermal Lag Issues 
-  Problem : Slow thermal response due to packaging or mounting
-  Solution : Minimize thermal mass between environment and sensor
-  Implementation : Use thermal conductive compounds and avoid insulating materials

 Pitfall 3: Data Integrity Concerns 
-  Problem : Potential data loss during read/write operations
-  Solution : Implement robust error checking and retry mechanisms
-  Implementation : Use CRC verification and multiple read attempts

### Compatibility Issues with Other Components

 Microcontroller Interface Compatibility: 
-  1-Wire Protocol : Requires precise timing (standard and overdrive modes)
-  Voltage Levels : Compatible with 3.3V and 5V systems with proper level shifting
-  Communication Distance : Limited to ~100 meters without signal conditioning

 Power Supply Considerations: 
-  Parasitic Power Mode : Can operate without local power supply
-  Strong Pull-up Requirement : Necessary for temperature conversions and EEPROM writes
-  Current Requirements : Peak current up to 1.5mA during active operations

 Environmental Compatibility: 
-  EM

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips