DS1921

Manufacturer: DS, DALLAS

High-Resolution Thermochron iButton

Partnumber Manufacturer Quantity Availability
DS1921 DS, DALLAS 357 In Stock

Description and Introduction

High-Resolution Thermochron iButton The DS1921 is a temperature logger manufactured by Maxim Integrated (now part of Analog Devices).  

### Key Specifications:  
- **Temperature Range**: -40°C to +85°C  
- **Accuracy**: ±1°C from -10°C to +85°C, ±2°C from -40°C to -10°C  
- **Resolution**: 0.5°C  
- **Memory**: 2048 bytes of NV SRAM for temperature logging  
- **Logging Interval**: Programmable from 1 minute to 273 hours  
- **Battery Life**: Up to 10 years (lithium battery-backed)  
- **Interface**: 1-Wire® communication protocol  
- **Unique 64-Bit ID**: Each device has a factory-lasered ROM ID  
- **Housing**: Stainless steel, waterproof (iButton form factor)  
- **Operating Voltage**: 2.8V to 5.25V  

The DS1921 is commonly used for environmental monitoring, cold chain logistics, and industrial temperature logging.  

Let me know if you need additional details.

Application Scenarios & Design Considerations

High-Resolution Thermochron iButton# DS1921 iButton Temperature Logger Technical Documentation

*Manufacturer: DALLAS (now part of Maxim Integrated)*

## 1. Application Scenarios

### Typical Use Cases
The DS1921 is a rugged, self-contained temperature logger in a compact iButton package that provides sophisticated temperature monitoring capabilities across various environments:

 Environmental Monitoring Applications: 
-  Cold Chain Logistics : Continuous temperature monitoring during transportation of pharmaceuticals, vaccines, and perishable foods
-  HVAC System Validation : Long-term temperature profiling in building management systems
-  Industrial Process Monitoring : Temperature tracking in manufacturing processes and quality control

 Medical and Healthcare Applications: 
-  Sterilization Validation : Monitoring autoclave cycles and sterilization processes
-  Laboratory Equipment : Temperature logging for incubators, refrigerators, and freezers
-  Clinical Trials : Ensuring proper temperature conditions for biological samples

 Industrial and Commercial Applications: 
-  Food Safety Compliance : HACCP monitoring in food processing and storage facilities
-  Electronic Component Testing : Environmental stress screening of electronic assemblies
-  Museum and Archive Preservation : Monitoring environmental conditions for artifact preservation

### Industry Applications

 Pharmaceutical Industry 
- Real-time temperature monitoring during drug manufacturing and distribution
- Compliance with FDA 21 CFR Part 11 requirements for electronic records
- Batch quality assurance through temperature history documentation

 Food and Beverage Industry 
- Supply chain temperature integrity verification
- Regulatory compliance documentation for food safety standards
- Quality control during production and storage processes

 Research and Development 
- Long-term environmental studies and data collection
- Prototype testing under various temperature conditions
- Scientific experiment monitoring and validation

### Practical Advantages and Limitations

 Advantages: 
-  Rugged Construction : Stainless steel package withstands harsh environments
-  Self-Contained Operation : No external power required during data logging
-  High Accuracy : ±1°C temperature accuracy across operating range
-  Large Memory Capacity : 2048 temperature readings with time-stamping
-  Easy Deployment : Simple contact-based interface reduces installation complexity

 Limitations: 
-  Limited Sampling Rate : Maximum sampling interval of 1 minute may be insufficient for rapid temperature changes
-  Contact-Based Interface : Requires physical contact for data retrieval
-  Fixed Memory Size : Cannot expand storage capacity for longer monitoring periods
-  Temperature Range : Limited to -40°C to +85°C operating range

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Insufficient Contact Reliability 
-  Problem : Poor electrical contact leads to communication failures
-  Solution : Implement spring-loaded contacts with adequate normal force (≥150g)
-  Implementation : Use gold-plated contacts and ensure proper alignment mechanisms

 Pitfall 2: Thermal Lag Issues 
-  Problem : Slow thermal response due to packaging or mounting
-  Solution : Minimize thermal mass between environment and sensor
-  Implementation : Use thermal conductive compounds and avoid insulating materials

 Pitfall 3: Data Integrity Concerns 
-  Problem : Potential data loss during read/write operations
-  Solution : Implement robust error checking and retry mechanisms
-  Implementation : Use CRC verification and multiple read attempts

### Compatibility Issues with Other Components

 Microcontroller Interface Compatibility: 
-  1-Wire Protocol : Requires precise timing (standard and overdrive modes)
-  Voltage Levels : Compatible with 3.3V and 5V systems with proper level shifting
-  Communication Distance : Limited to ~100 meters without signal conditioning

 Power Supply Considerations: 
-  Parasitic Power Mode : Can operate without local power supply
-  Strong Pull-up Requirement : Necessary for temperature conversions and EEPROM writes
-  Current Requirements : Peak current up to 1.5mA during active operations

 Environmental Compatibility: 
-  EM

Alternative Part Number

  • MAX31826 --: Temperature sensor with 1-Wire interface and integrated memory, functionally similar to the DS1921 Thermochron iButton for temperature logging applications.
  • DS1922L --: Higher-precision Thermochron iButton temperature logger from the same family, offering similar 1-Wire logging functionality with improved accuracy.
  • DS1923 --: Thermochron iButton with combined temperature and humidity logging, a superset alternative when environmental logging is required.
  • DS1921G-F5# --: Direct functional equivalent Thermochron iButton from the successor brand Maxim (now Analog Devices); same temperature-logging function and 1-Wire interface, drop-in compatible.
  • DS1922L-F5# --: Higher-accuracy Thermochron iButton in the same family with compatible 1-Wire interface and similar form factor, usable when improved temperature resolution is acceptable.
  • DS1923-F5# --: Hygrochron iButton with combined temperature and humidity logging in the same iButton package and 1-Wire protocol, suitable as a functional upgrade alternative.

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips