IC Phoenix logo

Home ›  C  › C5 > CC1101

CC1101 from TI,Texas Instruments

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

CC1101

Manufacturer: TI

Low-Power Sub-1GHz RF Transceiver

Partnumber Manufacturer Quantity Availability
CC1101 TI 104 In Stock

Description and Introduction

Low-Power Sub-1GHz RF Transceiver The CC1101 is a low-cost sub-1 GHz transceiver designed by Texas Instruments (TI). Here are its key specifications:

- **Frequency Range**: 300–348 MHz, 387–464 MHz, and 779–928 MHz  
- **Modulation**: Supports 2-FSK, GFSK, MSK, ASK, and OOK  
- **Data Rate**: Programmable from 0.6 to 500 kbps  
- **Sensitivity**: -116 dBm at 1.2 kbps (in 315/433/868/915 MHz bands)  
- **Output Power**: Up to +12 dBm (adjustable)  
- **Supply Voltage**: 1.8–3.6 V  
- **Current Consumption**:  
  - RX: 15.6 mA  
  - TX: 14 mA (at 0 dBm output)  
- **Package**: 20-pin QFN (4x4 mm)  
- **Interface**: SPI (4-wire)  
- **Operating Temperature**: -40°C to +85°C  

For detailed datasheets, refer to TI’s official documentation.

Application Scenarios & Design Considerations

Low-Power Sub-1GHz RF Transceiver# CC1101 Low-Power Sub-1 GHz RF Transceiver Technical Documentation

*Manufacturer: Texas Instruments (TI)*

## 1. Application Scenarios

### Typical Use Cases
The CC1101 is a highly versatile sub-1 GHz RF transceiver designed for low-power wireless applications in the 300-348 MHz, 387-464 MHz, and 779-928 MHz frequency bands. Its primary use cases include:

 Wireless Sensor Networks 
- Environmental monitoring systems (temperature, humidity, pressure sensors)
- Industrial automation sensors with periodic data transmission
- Agricultural monitoring systems for soil moisture and climate conditions
- Building automation sensors for occupancy detection and environmental control

 Remote Control Systems 
- Keyless entry systems and automotive remote controls
- Industrial remote control units for machinery operation
- Home automation controllers for lighting and appliance control
- Consumer electronics remote controls with extended range

 Data Telemetry Applications 
- Utility meter reading systems (water, gas, electricity)
- Medical device data transmission for patient monitoring
- Asset tracking and inventory management systems
- Remote data logging for scientific and industrial applications

### Industry Applications

 Industrial Automation 
-  Advantages : Robust performance in industrial environments, excellent penetration through obstacles, low power consumption for battery-operated sensors
-  Limitations : Limited data rate (500 kbps maximum) compared to 2.4 GHz alternatives
-  Typical Implementation : Machine-to-machine communication, process monitoring, equipment status reporting

 Smart Agriculture 
-  Advantages : Long-range capability (up to several kilometers with proper antenna design), resistance to foliage attenuation, low power for solar-powered systems
-  Limitations : Regional frequency band restrictions require careful planning
-  Typical Implementation : Soil sensor networks, irrigation control, livestock monitoring

 Consumer Electronics 
-  Advantages : Cost-effective solution, small form factor, excellent battery life
-  Limitations : Limited to simple data protocols, requires FCC/CE certification
-  Typical Implementation : Wireless toys, remote controls, smart home devices

 Medical Devices 
-  Advantages : Reliable communication in medical environments, low EMI characteristics
-  Limitations : Strict regulatory requirements for medical applications
-  Typical Implementation : Patient monitoring systems, medical sensor networks

### Practical Advantages and Limitations

 Key Advantages 
-  Low Power Consumption : 15.5 mA in RX mode, 29.5 mA in TX mode at +10 dBm
-  Excellent Sensitivity : -116 dBm at 0.6 kBaud, 315 MHz
-  Frequency Flexibility : Programmable for various sub-1 GHz bands
-  Integrated Features : Packet handling, data whitening, CRC checking
-  Cost-Effective : Lower cost compared to similar 2.4 GHz solutions

 Notable Limitations 
-  Data Rate : Maximum 500 kbps, unsuitable for high-bandwidth applications
-  Frequency Coordination : Requires careful regional frequency planning
-  Antenna Design : Critical for optimal performance, requires RF expertise
-  Regulatory Compliance : Must meet regional RF regulations (FCC, ETSI, etc.)

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Poor Frequency Stability 
-  Problem : Crystal oscillator drift causing frequency offset and reduced sensitivity
-  Solution : Use high-quality crystals (20 ppm or better), proper load capacitors, and follow TI's crystal specification guidelines

 Pitfall 2: Inadequate Power Supply Decoupling 
-  Problem : Voltage ripple causing spurious emissions and reduced sensitivity
-  Solution : Implement proper decoupling with 100 nF capacitors close to VDD pins, use ferrite beads for noise isolation

 Pitfall 3: Incorrect Impedance Matching 
-  Problem : Mismatched RF front-end causing reduced range and efficiency
-  Solution : Use TI

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips