IC Phoenix logo

Home ›  A  › A38 > ADS8345E/2K5

ADS8345E/2K5 from TI,Texas Instruments

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

ADS8345E/2K5

Manufacturer: TI

16-Bit, 8-Channel Serial Output Sampling Analog-to-Digital Converter

Partnumber Manufacturer Quantity Availability
ADS8345E/2K5,ADS8345E2K5 TI 2 In Stock

Description and Introduction

16-Bit, 8-Channel Serial Output Sampling Analog-to-Digital Converter The ADS8345E/2K5 is a 16-bit, 4-channel, successive approximation register (SAR) analog-to-digital converter (ADC) manufactured by Texas Instruments (TI). Key specifications include:

- **Resolution**: 16 bits
- **Channels**: 4 single-ended or 2 differential inputs
- **Sampling Rate**: Up to 100 kSPS (kilo samples per second)
- **Interface**: Serial SPI-compatible
- **Supply Voltage**: 2.7V to 5V
- **Power Consumption**: 2.5 mW (typical) at 5V and 100 kSPS
- **Operating Temperature Range**: -40°C to +85°C
- **Package**: 20-pin SSOP (Shrink Small Outline Package)
- **Reference Voltage**: External reference required, range from 1V to VCC
- **Input Voltage Range**: 0V to VREF
- **DNL (Differential Non-Linearity)**: ±1 LSB (max)
- **INL (Integral Non-Linearity)**: ±2 LSB (max)
- **Analog Input Impedance**: 1 MΩ (typical)

This ADC is designed for precision data acquisition applications, including industrial control, medical instrumentation, and portable devices.

Application Scenarios & Design Considerations

16-Bit, 8-Channel Serial Output Sampling Analog-to-Digital Converter# ADS8345E2K5 Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The ADS8345E2K5 is a 16-bit, 4-channel successive approximation register (SAR) analog-to-digital converter (ADC) with serial interface, making it suitable for various precision measurement applications:

 Data Acquisition Systems 
- Multi-channel sensor monitoring (temperature, pressure, strain gauges)
- Industrial process control systems requiring simultaneous multi-parameter measurement
- Medical instrumentation for vital sign monitoring

 Portable Measurement Equipment 
- Battery-powered data loggers due to low power consumption (2.5mW typical)
- Field measurement devices requiring high resolution in compact form factors
- Handheld test and measurement instruments

 Automated Test Equipment 
- Precision voltage and current measurement systems
- Calibration equipment requiring 16-bit resolution
- Production line testing systems

### Industry Applications

 Industrial Automation 
- PLC analog input modules
- Motor control feedback systems
- Process variable monitoring (4-20mA loops)
- *Advantage*: Excellent DC accuracy and low noise performance
- *Limitation*: Limited to 100kHz sampling rate per channel

 Medical Devices 
- Patient monitoring equipment
- Portable diagnostic instruments
- Biomedical sensor interfaces
- *Advantage*: Low power operation enables portable designs
- *Limitation*: Requires external anti-aliasing filters for high-frequency noise rejection

 Energy Management 
- Smart grid monitoring systems
- Power quality analysis equipment
- Renewable energy system monitoring
- *Advantage*: Wide input voltage range (0V to VREF) accommodates various signal conditioning outputs

 Automotive Systems 
- Battery management systems
- Sensor monitoring in electric vehicles
- Advanced driver assistance systems (ADAS)
- *Advantage*: Operates across industrial temperature range (-40°C to +85°C)

### Practical Advantages and Limitations

 Advantages: 
-  High Resolution : 16-bit no missing codes ensures precise measurements
-  Low Power : 2.5mW at 100kHz enables battery-operated applications
-  Small Package : SSOP-20 package saves board space
-  Flexible Interface : SPI-compatible serial interface simplifies microcontroller integration
-  Internal Reference : Can operate with external or internal reference

 Limitations: 
-  Speed Limitation : Maximum 100kHz sampling rate limits high-speed applications
-  Channel Sequencing : Manual channel selection via control byte
-  Power Supply Sensitivity : Requires clean analog and digital power supplies

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Power Supply Decoupling 
- *Pitfall*: Inadequate decoupling causing noise and accuracy degradation
- *Solution*: Use 10μF tantalum capacitor at power entry plus 0.1μF ceramic capacitor placed close to each power pin

 Reference Voltage Stability 
- *Pitfall*: Using noisy or unstable reference voltage affecting ADC accuracy
- *Solution*: Implement proper reference buffer with adequate decoupling; use low-noise reference ICs like REF50xx series

 Digital Noise Coupling 
- *Pitfall*: Digital switching noise coupling into analog signals
- *Solution*: Separate analog and digital grounds with single-point connection; use ferrite beads on digital lines

### Compatibility Issues with Other Components

 Microcontroller Interface 
- Compatible with most SPI masters
- Ensure microcontroller SPI clock meets timing requirements (max 5MHz)
- Verify logic level compatibility (2.7V to 5V operation)

 Signal Conditioning Circuits 
- Input impedance of 1MΩ typical allows direct connection to most op-amp outputs
- Requires input protection for signals exceeding supply rails
- Compatible with instrumentation amplifiers like INA826 for differential measurements

 Voltage Reference 
- External reference voltage range: 500mV to V

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips