IC Phoenix logo

Home ›  A  › A35 > ADS1198CPAG

ADS1198CPAG from TI/BB,Texas Instruments

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

ADS1198CPAG

Manufacturer: TI/BB

Low-Noise, 8 Channel, 16 Bit Analog Front End for ECG/EEG Measurements 64-TQFP 0 to 70

Partnumber Manufacturer Quantity Availability
ADS1198CPAG TI/BB 166 In Stock

Description and Introduction

Low-Noise, 8 Channel, 16 Bit Analog Front End for ECG/EEG Measurements 64-TQFP 0 to 70 The ADS1198CPAG is a multichannel, simultaneous sampling, 24-bit analog-to-digital converter (ADC) manufactured by Texas Instruments (TI)/Burr-Brown (BB). It features 8 low-noise programmable gain amplifiers (PGAs) and 8 high-resolution ADCs. The device is designed for high-precision data acquisition applications, such as medical instrumentation, industrial process control, and test and measurement systems. Key specifications include:

- **Resolution**: 24-bit
- **Channels**: 8 simultaneous sampling channels
- **Input Type**: Differential
- **Data Rate**: Up to 8 kSPS (kilo samples per second)
- **PGA Gain**: Programmable from 1 to 12
- **Input Voltage Range**: ±2.5 V (with PGA gain of 1)
- **Power Supply**: +5 V analog, +1.8 V to +3.3 V digital
- **Operating Temperature Range**: -40°C to +85°C
- **Package**: 64-pin TQFP (Thin Quad Flat Package)
- **Interface**: SPI-compatible serial interface
- **Features**: Built-in reference, internal oscillator, and self-calibration

The ADS1198CPAG is designed for applications requiring high accuracy and low noise performance.

Application Scenarios & Design Considerations

Low-Noise, 8 Channel, 16 Bit Analog Front End for ECG/EEG Measurements 64-TQFP 0 to 70# ADS1198CPAG Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The ADS1198CPAG is an 8-channel, 24-bit analog-to-digital converter specifically designed for  biopotential measurement applications . Its primary use cases include:

-  Medical ECG Systems : Simultaneous acquisition of 8-lead electrocardiogram signals with excellent common-mode rejection
-  Patient Monitoring : Continuous vital sign monitoring in hospital settings with low-power operation
-  Portable Medical Devices : Battery-powered Holter monitors and ambulatory ECG recorders
-  Fitness/Wellness Equipment : Heart rate monitoring in consumer health devices
-  EMG/EEG Applications : Electromyography and electroencephalography signal acquisition

### Industry Applications

 Medical & Healthcare 
- Clinical-grade diagnostic ECG machines
- Telemedicine patient monitoring systems
- Emergency medical service equipment
- Veterinary medical monitoring devices

 Research & Laboratory 
- Biomedical research instrumentation
- Physiological signal analysis systems
- Academic research platforms

 Industrial Monitoring 
- Structural health monitoring (vibration analysis)
- Condition monitoring systems requiring multiple sensor inputs

### Practical Advantages

 Strengths: 
-  High Integration : 8 simultaneous sampling channels reduce component count
-  Excellent CMRR : >110 dB at 60 Hz enables reliable operation in noisy environments
-  Low Power : 0.75 mW per channel supports portable applications
-  Built-in Features : Integrated right leg drive amplifier and lead-off detection
-  Flexible Data Rates : Programmable from 125 SPS to 8 kSPS
-  Small Package : 64-TQFP (10×10 mm) saves board space

 Limitations: 
-  Fixed Channel Count : 8 channels may be insufficient for high-density EEG applications
-  Input Range : ±2.4 V maximum may require additional front-end conditioning for some sensors
-  Digital Interface : SPI-only interface limits compatibility with some microcontrollers
-  Cost : Premium pricing compared to general-purpose ADCs

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Power Supply Sequencing 
-  Problem : Improper power-up sequencing can latch the device
-  Solution : Ensure AVDD ≤ DVDD + 0.3V during power-up; use controlled sequencing circuits

 Reference Voltage Stability 
-  Problem : Poor reference stability affects measurement accuracy
-  Solution : Use low-noise, low-drift reference sources (e.g., REF5025) with proper decoupling

 Lead-Off Detection Reliability 
-  Problem : False lead-off detection in dry electrode applications
-  Solution : Adjust lead-off detection current settings and implement software filtering

### Compatibility Issues

 Microcontroller Interface 
-  Compatible : Most modern microcontrollers with hardware SPI (STM32, PIC, MSP430)
-  Incompatible : Processors without SPI hardware support requiring bit-banged implementation

 Sensor Compatibility 
-  Direct Interface : ECG electrodes, EMG sensors, piezoelectric sensors
-  Requires Conditioning : High-impedance pH sensors, thermocouples (need buffer amplifiers)

 Power Supply Requirements 
-  Analog Supply : +2.7V to +5.25V (AVDD to AVSS = 5V max)
-  Digital Supply : +1.65V to +3.6V (DVDD to DGND)
-  Note : Maintain proper supply sequencing to prevent latch-up

### PCB Layout Recommendations

 Power Supply Decoupling 
- Place 10 μF tantalum and 100 nF ceramic capacitors within 5 mm of each power pin
- Use separate ground planes for analog and digital sections
- Implement star-point grounding at the ADC's ground reference

 Signal Routing 
- Route differential input pairs as closely spaced, equal-length traces
- Keep high-impedance analog

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips