ADM2587EBRWZ

Manufacturer: ADI

Signal and Power Isolated RS-485 Transceiver with ±15 kV ESD Protection

Partnumber Manufacturer Quantity Availability
ADM2587EBRWZ ADI 1600 In Stock

Description and Introduction

Signal and Power Isolated RS-485 Transceiver with ±15 kV ESD Protection The ADM2587EBRWZ is a fully integrated signal and power isolated data transceiver manufactured by Analog Devices Inc. (ADI). It features a 5 kV rms signal and power isolation, and supports data rates up to 16 Mbps. The device operates with a single 5 V power supply and includes integrated isolated DC-DC converters. It is designed for RS-485/RS-422 communication and complies with the TIA/EIA-485-A and ISO 8482:1987(E) standards. The ADM2587EBRWZ is available in a 20-lead wide body SOIC package and operates over an industrial temperature range of -40°C to +85°C. It also includes features such as fail-safe receiver inputs, thermal shutdown, and short-circuit protection.

Application Scenarios & Design Considerations

Signal and Power Isolated RS-485 Transceiver with ±15 kV ESD Protection # ADM2587EBRWZ - Isolated RS-485/RS-422 Transceiver Technical Documentation

 Manufacturer : Analog Devices Inc. (ADI)

## 1. Application Scenarios

### Typical Use Cases
The ADM2587EBRWZ is a fully integrated, isolated RS-485/RS-422 transceiver designed for robust industrial communication applications. Key use cases include:

-  Industrial Fieldbus Networks : Implements PROFIBUS, Modbus, and other industrial protocols in harsh environments
-  Motor Control Systems : Provides noise-immune communication between controllers and motor drives
-  Process Automation : Connects PLCs to remote I/O modules across different ground potentials
-  Building Automation : Links HVAC controllers, lighting systems, and security devices over long distances
-  Renewable Energy Systems : Interfaces between inverters and monitoring equipment in solar/wind installations

### Industry Applications
-  Factory Automation : Used in assembly lines, robotic systems, and material handling equipment
-  Power Distribution : Implemented in smart grid systems, power quality monitors, and protective relays
-  Transportation Systems : Deployed in railway signaling, traffic control, and vehicle telematics
-  Medical Equipment : Applied in patient monitoring systems and diagnostic equipment requiring electrical isolation
-  Telecommunications : Serves in base station equipment and network infrastructure

### Practical Advantages and Limitations

 Advantages: 
-  Integrated Isolation : 2.5 kV RMS isolation eliminates need for external isolation components
-  High Noise Immunity : Excellent common-mode rejection (≥25 kV/μs) in electrically noisy environments
-  Low Power Operation : 2.5 mA typical supply current in shutdown mode
-  Robust ESD Protection : ±15 kV human body model protection on bus pins
-  Wide Temperature Range : Operates from -40°C to +85°C for industrial applications

 Limitations: 
-  Data Rate Constraint : Maximum 16 Mbps may be insufficient for high-speed applications
-  Power Supply Requirements : Requires both 3.3V and 5V supplies for full functionality
-  Package Size : 20-lead SOIC_W package may be large for space-constrained designs
-  Cost Consideration : Higher unit cost compared to non-isolated alternatives

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Insufficient Power Supply Decoupling 
-  Problem : Inadequate decoupling causes signal integrity issues and EMI problems
-  Solution : Use 0.1 μF ceramic capacitors placed close to VCC and VISO pins, with additional 10 μF bulk capacitors

 Pitfall 2: Improper Termination 
-  Problem : Signal reflections due to missing or incorrect termination resistors
-  Solution : Include 120Ω termination resistors at both ends of the bus, with bias resistors for fail-safe operation

 Pitfall 3: Ground Loop Issues 
-  Problem : Current flow between different ground potentials through shield connections
-  Solution : Use single-point grounding and consider shield connection through capacitor or transient suppressor

 Pitfall 4: Thermal Management 
-  Problem : Overheating in high-temperature environments or during fault conditions
-  Solution : Ensure adequate PCB copper area for heat dissipation and maintain proper airflow

### Compatibility Issues with Other Components

 Microcontroller Interfaces: 
- Compatible with 3.3V and 5V logic families
- Requires level shifting when interfacing with 1.8V devices
- Watch for timing constraints with slow microcontrollers

 Power Supply Requirements: 
- VCC (logic side): 3.0V to 3.6V or 4.5V to 5.5V
- VISO (isolated side): 4.5V to 5.5V
- Ensure proper

Partnumber Manufacturer Quantity Availability
ADM2587EBRWZ ADPb 2000 In Stock

Description and Introduction

Signal and Power Isolated RS-485 Transceiver with ±15 kV ESD Protection The ADM2587EBRWZ is a fully integrated signal and power isolated data transceiver with ±15 kV ESD protection, manufactured by Analog Devices (AD). It is designed for RS-485/RS-422 communication and operates with a supply voltage range of 3.3V or 5V. The device features integrated isolation for both the data and power lines, providing up to 2.5 kV RMS isolation. It supports data rates up to 16 Mbps and includes a fail-safe feature to ensure the receiver output is in a known state when the inputs are open or shorted. The ADM2587EBRWZ is available in a 20-lead wide-body SOIC package and operates over an industrial temperature range of -40°C to +85°C.

Application Scenarios & Design Considerations

Signal and Power Isolated RS-485 Transceiver with ±15 kV ESD Protection # ADM2587EBRWZ Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The ADM2587EBRWZ is a fully isolated RS-485/RS-422 transceiver widely employed in industrial communication systems requiring robust electrical isolation and high-speed data transmission. Key applications include:

 Industrial Automation Systems 
- PLC-to-PLC communication networks
- Motor control and drive systems
- Sensor data acquisition networks
- Distributed I/O module interfaces

 Building Automation 
- HVAC control systems
- Lighting control networks
- Security and access control systems
- Energy management systems

 Process Control Applications 
- Process instrumentation loops
- SCADA system field communications
- Remote terminal unit (RTU) interfaces
- Distributed control system (DCS) networks

### Industry Applications
-  Factory Automation : Machine-to-machine communication in harsh industrial environments
-  Power Systems : Substation automation and power quality monitoring
-  Transportation : Railway signaling and vehicle control systems
-  Medical Equipment : Patient monitoring systems requiring electrical isolation
-  Telecommunications : Base station equipment and network infrastructure

### Practical Advantages
 Key Benefits: 
-  5 kV RMS isolation  provides superior protection against ground loops and voltage transients
-  Integrated DC-DC converter  eliminates need for external isolated power supply
-  ±15 kV ESD protection  on bus pins ensures reliability in harsh environments
-  High-speed operation  up to 16 Mbps supports demanding industrial applications
-  Low power consumption  (70 mW typical) suitable for power-constrained systems

 Limitations and Constraints: 
-  Thermal considerations : Maximum junction temperature of 125°C requires proper thermal management
-  Power supply sequencing : Careful timing required between VDD1 and VDD2 power-up
-  EMI sensitivity : Proper filtering needed in high-noise environments
-  Cost consideration : Higher unit cost compared to non-isolated alternatives

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Power Supply Issues 
-  Pitfall : Inadequate decoupling causing signal integrity problems
-  Solution : Use 0.1 μF ceramic capacitors placed close to all power pins, plus 10 μF bulk capacitors

 Grounding Problems 
-  Pitfall : Improper isolation barrier grounding compromising isolation performance
-  Solution : Maintain clear separation between isolated and non-isolated ground planes

 Signal Integrity Challenges 
-  Pitfall : Reflections due to improper termination
-  Solution : Implement 120Ω termination resistors at cable ends and proper stub length management

### Compatibility Issues

 Microcontroller Interfaces 
-  3.3V/5V Logic Compatibility : The device supports both voltage levels but requires careful level shifting when interfacing with mixed-voltage systems
-  Clock Synchronization : Ensure proper timing margins when interfacing with high-speed processors

 Bus Loading Considerations 
-  Unit Load Compatibility : 1/8 unit load allows up to 256 devices on the bus
-  Cable Length vs. Data Rate : Balance between maximum cable length and data rate requirements

### PCB Layout Recommendations

 Isolation Barrier Implementation 
```
+----------------+    Isolation    +----------------+
| Logic Side     |     Barrier     | Bus Side       |
| GND1           |                 | GND2           |
| VDD1           |                 | VDD2           |
+----------------+    >5mm gap     +----------------+
```

 Critical Layout Guidelines: 
- Maintain minimum  5 mm creepage and clearance  distance across isolation barrier
- Use  guard rings  around high-impedance nodes
- Place  bypass capacitors  within 5 mm of power pins
- Route  differential pairs  with controlled impedance (100-120Ω)

 Thermal Management 
- Provide adequate copper pour for heat dissipation
- Consider thermal vias under the

Request Quotation