AD587LQ

Manufacturer: AD

High Precision 10 V Reference

Partnumber Manufacturer Quantity Availability
AD587LQ AD 520 In Stock

Description and Introduction

High Precision 10 V Reference The AD587LQ is a precision voltage reference manufactured by Analog Devices (AD). It provides a fixed output voltage of 10 V with high accuracy and stability. Key specifications include:

- **Output Voltage**: 10 V
- **Initial Accuracy**: ±0.01% (max)
- **Temperature Coefficient**: 5 ppm/°C (max)
- **Long-Term Stability**: 15 ppm/1000 hours (typ)
- **Output Current**: 10 mA (max)
- **Operating Temperature Range**: -40°C to +85°C
- **Package**: 8-lead CERDIP

The AD587LQ is designed for applications requiring precise voltage references, such as in data acquisition systems, digital-to-analog converters, and precision instrumentation.

Application Scenarios & Design Considerations

High Precision 10 V Reference# AD587LQ Precision Voltage Reference - Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The AD587LQ serves as a high-precision voltage reference in critical analog circuits where stable reference voltages are paramount. Primary applications include:

-  Precision Analog-to-Digital Converters (ADCs) : Provides stable reference voltages for 12-bit to 16-bit ADCs in measurement systems
-  Digital-to-Analog Converters (DACs) : Ensures accurate output voltage generation in high-resolution DAC applications
-  Calibration Systems : Used as reference standard in laboratory equipment and calibration instruments
-  Data Acquisition Systems : Maintains measurement accuracy across temperature variations in industrial DAQ systems
-  Portable Instrumentation : Battery-powered devices requiring low power consumption with high accuracy

### Industry Applications
 Industrial Automation 
- Process control systems requiring ±0.01% initial accuracy
- Temperature measurement systems with long-term stability requirements
- PLC analog input modules where consistent reference is critical

 Medical Equipment 
- Patient monitoring devices demanding reliable voltage references
- Diagnostic equipment requiring stable biasing voltages
- Portable medical instruments where power efficiency matters

 Test and Measurement 
- Digital multimeters and oscilloscopes
- Spectrum analyzers and signal generators
- Calibration standards and reference sources

 Communications Systems 
- Base station power management circuits
- RF power amplifier bias circuits
- Signal conditioning in transceiver systems

### Practical Advantages and Limitations

 Advantages: 
-  High Initial Accuracy : ±1mV (0.01%) typical at 25°C
-  Excellent Temperature Stability : 5ppm/°C maximum temperature coefficient
-  Low Noise Performance : <10μV p-p (0.1Hz to 10Hz)
-  Long-Term Stability : 25ppm/1000 hours typical
-  Wide Operating Range : -40°C to +85°C industrial temperature range
-  Low Power Consumption : 1.5mA maximum supply current

 Limitations: 
-  Limited Output Current : 10mA maximum output current capability
-  Sensitivity to Load Changes : Requires stable, minimal load variations
-  PCB Layout Sensitivity : Performance dependent on proper board design
-  Cost Consideration : Higher cost compared to general-purpose references
-  Limited Output Voltage Options : Fixed 10V output only

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Power Supply Rejection Issues 
-  Pitfall : Inadequate power supply filtering causing reference noise
-  Solution : Implement π-filter (10Ω resistor with 10μF tantalum and 0.1μF ceramic capacitors) at supply input

 Thermal Management Problems 
-  Pitfall : Poor thermal design causing temperature-induced drift
-  Solution : 
  - Place away from heat-generating components
  - Use thermal relief patterns in PCB
  - Consider thermal vias for heat dissipation

 Load Regulation Challenges 
-  Pitfall : Dynamic load changes affecting reference stability
-  Solution : 
  - Buffer reference output with precision op-amp for varying loads
  - Maintain load current below 5mA for optimal performance

### Compatibility Issues with Other Components

 ADC/DAC Interface Considerations 
-  Input Capacitance : AD587LQ can drive up to 1000pF capacitive load directly
-  Reference Input Requirements : Compatible with most precision ADCs (AD574, AD7671, etc.)
-  Settling Time : Allow 10μs settling time after power-up or load changes

 Digital Circuit Isolation 
-  Noise Coupling : Separate analog and digital grounds
-  Supply Decoupling : Use separate LDO regulators for analog and digital sections
-  Clock Noise : Keep high-speed digital signals away from reference circuitry

### PCB Layout Recommendations

Partnumber Manufacturer Quantity Availability
AD587LQ 26 In Stock

Description and Introduction

High Precision 10 V Reference The AD587LQ is a precision voltage reference manufactured by Analog Devices. It provides a fixed output voltage of 10 V with high accuracy and stability. Key specifications include:

- Output Voltage: 10 V
- Initial Accuracy: ±0.01% (max)
- Temperature Coefficient: 1.5 ppm/°C (max)
- Long-Term Stability: 15 ppm/1000 hours (typ)
- Output Current: 10 mA (max)
- Operating Temperature Range: -40°C to +85°C
- Package: 8-lead CERDIP (LQ package)

The AD587LQ is designed for applications requiring precise voltage references, such as in data acquisition systems, digital-to-analog converters, and precision instrumentation.

Application Scenarios & Design Considerations

High Precision 10 V Reference# AD587LQ Precision Voltage Reference - Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The AD587LQ serves as a high-precision voltage reference in critical analog circuits where stable reference voltages are essential. Primary applications include:

 Data Acquisition Systems 
- Provides stable reference for high-resolution ADCs (16-bit and above)
- Ensures accurate analog-to-digital conversion in measurement equipment
- Maintains precision in multi-channel data acquisition systems

 Precision Instrumentation 
- Reference source for laboratory-grade multimeters and oscilloscopes
- Calibration reference in test and measurement equipment
- Medical diagnostic equipment requiring high accuracy

 Industrial Control Systems 
- Process control instrumentation reference
- Temperature measurement systems
- Pressure and flow monitoring equipment

### Industry Applications

 Aerospace and Defense 
- Avionics systems requiring MIL-STD-883 compliance
- Radar and communication equipment
- Navigation and guidance systems

 Medical Electronics 
- Patient monitoring equipment
- Diagnostic imaging systems
- Laboratory analytical instruments

 Telecommunications 
- Base station power management
- Network timing and synchronization circuits
- High-speed data conversion systems

### Practical Advantages and Limitations

 Advantages: 
-  High Initial Accuracy : ±1mV maximum error at 25°C
-  Low Temperature Drift : 5ppm/°C maximum
-  Excellent Long-Term Stability : 25ppm/1000 hours
-  Low Noise Performance : 100nV/√Hz typical
-  Wide Operating Temperature : -40°C to +85°C

 Limitations: 
-  Limited Output Current : 10mA maximum output capability
-  Power Supply Requirements : Requires clean, regulated input voltage
-  Temperature Sensitivity : Performance degrades at temperature extremes
-  Cost Considerations : Premium pricing compared to standard references

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Power Supply Rejection 
-  Pitfall : Inadequate PSRR leading to reference voltage fluctuations
-  Solution : Implement proper decoupling with 10μF tantalum and 0.1μF ceramic capacitors
-  Implementation : Place decoupling capacitors within 5mm of power pins

 Thermal Management 
-  Pitfall : Thermal gradients affecting reference stability
-  Solution : Use thermal vias and avoid heat-generating components nearby
-  Implementation : Maintain minimum 10mm clearance from power devices

 Load Regulation Issues 
-  Pitfall : Output voltage droop under dynamic loads
-  Solution : Buffer output with precision operational amplifier
-  Implementation : Use low-offset, low-drift op-amp in voltage follower configuration

### Compatibility Issues

 ADC Interface Considerations 
-  Issue : Reference impedance affecting conversion accuracy
-  Resolution : Use low-impedance buffer or select ADC with high input impedance
-  Compatible ADCs : AD7671, LTC2400, MAX11270

 Digital System Integration 
-  Issue : Digital noise coupling into reference output
-  Resolution : Implement proper grounding separation and filtering
-  Best Practice : Use star grounding and separate analog/digital grounds

 Power Supply Compatibility 
-  Minimum Operating Voltage : +12V to +15V recommended
-  Maximum Voltage : 36V absolute maximum
-  Current Consumption : 1.5mA typical quiescent current

### PCB Layout Recommendations

 Component Placement 
- Position AD587LQ away from heat sources and digital components
- Keep decoupling capacitors as close as possible to device pins
- Maintain symmetrical layout for balanced thermal distribution

 Routing Guidelines 
- Use dedicated ground plane for reference circuitry
- Route reference output as a protected trace with ground shielding
- Minimize trace length between reference and load components

 Thermal Considerations 
- Provide adequate copper area for heat dissipation
- Use

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips