IC Phoenix logo

Home ›  A  › A10 > AD586JN

AD586JN from AD,Analog Devices

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

AD586JN

Manufacturer: AD

High Precision 5 V Reference

Partnumber Manufacturer Quantity Availability
AD586JN AD 13368 In Stock

Description and Introduction

High Precision 5 V Reference The AD586JN is a precision voltage reference manufactured by Analog Devices (AD). It provides a stable 5.0V output with high accuracy and low temperature drift. Key specifications include:

- **Output Voltage**: 5.0V ± 0.4mV (typical)
- **Initial Accuracy**: ±0.04% (max)
- **Temperature Coefficient**: 5 ppm/°C (max) over the full temperature range
- **Operating Temperature Range**: -40°C to +85°C
- **Line Regulation**: 0.5 mV/V (max)
- **Load Regulation**: 0.5 mV/mA (max)
- **Long-Term Stability**: 25 ppm/1000 hours (typical)
- **Supply Voltage Range**: 7V to 36V
- **Quiescent Current**: 1.5 mA (typical)
- **Package**: 8-pin PDIP (Plastic Dual In-line Package)

The AD586JN is designed for applications requiring high precision and stability, such as data acquisition systems, digital voltmeters, and precision power supplies.

Application Scenarios & Design Considerations

High Precision 5 V Reference# AD586JN Precision Voltage Reference - Technical Documentation

## 1. Application Scenarios

### Typical Use Cases
The AD586JN serves as a high-precision +5V voltage reference in various critical applications:

 Primary Applications: 
-  Analog-to-Digital Converter (ADC) Reference : Provides stable reference voltage for 12-bit to 16-bit ADCs in measurement systems
-  Digital-to-Analog Converter (DAC) Reference : Ensures accurate output voltage generation in precision DAC circuits
-  Voltage Calibration Standards : Used as a secondary standard in calibration equipment and test fixtures
-  Sensor Excitation : Powers bridge sensors (strain gauges, pressure sensors) requiring precise excitation voltages
-  Voltage Monitoring Circuits : Reference for undervoltage/overvoltage detection systems

### Industry Applications
 Industrial Automation: 
- PLC analog I/O modules requiring ±0.1% accuracy
- Process control instrumentation (temperature controllers, pressure transmitters)
- Motor drive feedback systems

 Test and Measurement: 
- Digital multimeters and data acquisition systems
- Laboratory power supplies and electronic loads
- Automatic test equipment (ATE) calibration references

 Medical Equipment: 
- Patient monitoring systems (ECG, blood pressure monitors)
- Diagnostic imaging equipment analog front-ends
- Portable medical devices requiring stable references

 Communications: 
- Base station power management and monitoring
- RF power amplifier bias control circuits
- Network equipment voltage monitoring

### Practical Advantages and Limitations

 Advantages: 
-  High Initial Accuracy : ±1mV maximum error at +25°C
-  Low Temperature Coefficient : 5ppm/°C maximum (K grade)
-  Excellent Long-Term Stability : 25ppm/1000 hours typical
-  Low Noise Performance : 5μV p-p typical (0.1Hz to 10Hz)
-  Wide Operating Range : -40°C to +85°C industrial temperature range
-  Simple Implementation : Requires minimal external components

 Limitations: 
-  Fixed Output Voltage : Only provides +5V output (not adjustable)
-  Limited Current Output : 10mA maximum output current
-  Power Supply Sensitivity : Requires clean, well-regulated input voltage
-  Cost Consideration : Higher cost compared to bandgap references for non-critical applications

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Power Supply Issues: 
-  Pitfall : Insufficient input voltage headroom (requires V+ ≥ 6.5V)
-  Solution : Ensure minimum 1.5V dropout voltage; use 7-15V input range for optimal performance
-  Pitfall : Poor power supply rejection leading to noise injection
-  Solution : Implement proper decoupling with 10μF tantalum + 0.1μF ceramic capacitors at input

 Load Regulation Problems: 
-  Pitfall : Excessive load current (>10mA) causing output droop
-  Solution : Add buffer amplifier (OP-07, AD708) for higher current requirements
-  Pitfall : Dynamic load changes affecting reference stability
-  Solution : Use local bypass capacitors and minimize trace inductance

 Thermal Management: 
-  Pitfall : Poor thermal layout causing temperature gradients
-  Solution : Provide adequate copper area for heat dissipation, avoid heat sources

### Compatibility Issues with Other Components

 ADC/DAC Interface: 
-  Compatible ADCs : AD574, AD1674, MAX1241 (12-bit systems)
-  Interface Considerations : Add series resistor (10-100Ω) to limit current during ADC sample-and-hold switching
-  Noise Coupling : Separate analog and digital grounds, use star grounding

 Amplifier Compatibility: 
-  Recommended Op-Amps : OP-07, AD707, LT101

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips