IC Phoenix logo

Home ›  7  › 730 > 78253/55VC

78253/55VC from C&D

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

78253/55VC

Manufacturer: C&D, muRata Ps, muRataPS

MAX253 Compatible Converter Transformers 3.3V and 5V versions

Partnumber Manufacturer Quantity Availability
78253/55VC,7825355VC C&D, muRata Ps, muRataPS 1763 In Stock

Description and Introduction

MAX253 Compatible Converter Transformers 3.3V and 5V versions The part number 78253/55VC is manufactured by muRataPS. The specifications for this part include:

- **Input Voltage Range:** 85-264VAC
- **Output Voltage:** 5V
- **Output Current:** 2.5A
- **Power Rating:** 12.5W
- **Efficiency:** Up to 88%
- **Operating Temperature Range:** -40°C to +85°C
- **Safety Approvals:** UL/cUL, EN60950, TUV
- **Protection Features:** Overcurrent, Overvoltage, Short Circuit, Over Temperature
- **Dimensions:** 2.00" x 1.00" x 0.50" (50.8mm x 25.4mm x 12.7mm)
- **Weight:** 0.1 lbs (45g)
- **Mounting Type:** Through Hole
- **Regulation:** ±5% Line and Load Regulation
- **Isolation Voltage:** 3000VAC

These specifications are based on the standard model and may vary slightly depending on the specific version or revision of the part.

Application Scenarios & Design Considerations

MAX253 Compatible Converter Transformers 3.3V and 5V versions# Technical Documentation: 7825355VC DC-DC Converter Module

*Manufacturer: muRataPS*

## 1. Application Scenarios

### Typical Use Cases
The 7825355VC is a high-efficiency DC-DC converter module primarily employed in distributed power architectures where intermediate bus voltage conversion is required. Typical applications include:

-  Intermediate Bus Conversion : Converting 48V backplane power to lower intermediate bus voltages (typically 12V) for subsequent point-of-load regulation
-  Telecommunications Equipment : Powering line cards, network interface modules, and communication processors in telecom infrastructure
-  Industrial Automation : Providing regulated power for PLCs, motor controllers, and industrial computing systems
-  Server and Data Center Applications : Powering server blades, storage systems, and networking equipment

### Industry Applications
-  Telecommunications : Base stations, routers, switches, and optical transport equipment
-  Industrial Control : Factory automation systems, process control equipment, and test/measurement instruments
-  Enterprise Computing : Server racks, storage arrays, and networking hardware
-  Medical Equipment : Diagnostic imaging systems and patient monitoring devices requiring reliable power conversion

### Practical Advantages and Limitations

 Advantages: 
-  High Efficiency : Typically 94-96% efficiency across load range, reducing thermal management requirements
-  Compact Form Factor : Industry-standard quarter-brick package (2.28" × 1.45") with low profile
-  Wide Input Range : Operates from 36V to 75V input, accommodating standard 48V nominal systems
-  Thermal Performance : Excellent thermal characteristics with baseplate cooling capability
-  EMI Performance : Meets EN55022 Class B emissions standards with proper filtering

 Limitations: 
-  Fixed Output Voltage : Limited output voltage flexibility without external compensation
-  Minimum Load Requirement : May require minimum load for proper regulation (typically 10% of full load)
-  Cost Consideration : Higher unit cost compared to discrete solutions for high-volume applications
-  External Components : Requires input/output filtering and protection components for optimal performance

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Input Voltage Transients 
-  Issue : Telecom and industrial environments often experience input voltage spikes exceeding maximum ratings
-  Solution : Implement TVS diodes and input capacitors to absorb transients; ensure proper derating for worst-case scenarios

 Pitfall 2: Thermal Management 
-  Issue : Inadequate heat sinking leading to thermal shutdown or reduced reliability
-  Solution : Use thermal interface materials and proper mounting techniques; ensure adequate airflow or heat sinking

 Pitfall 3: Output Stability 
-  Issue : Oscillations or instability with certain load types or output capacitor combinations
-  Solution : Follow manufacturer recommendations for output capacitance and ESR; use stable ceramic and polymer capacitors

### Compatibility Issues with Other Components

 Input Filter Compatibility: 
- Ensure input filter resonance frequency doesn't interact with converter switching frequency
- Coordinate with upstream power sources to prevent system-level stability issues

 Load Compatibility: 
- Some highly dynamic loads may require additional bulk capacitance
- Coordinate with point-of-load converters to ensure proper system stability

 Control Interface: 
- Power-good and enable signals require proper level translation when interfacing with different logic families
- Consider isolation requirements for systems with different ground domains

### PCB Layout Recommendations

 Power Path Layout: 
- Use wide, short traces for input and output power paths to minimize parasitic inductance
- Place input capacitors close to the module pins to reduce high-frequency loop area
- Maintain continuous ground planes for optimal thermal and EMI performance

 Thermal Management: 
- Provide adequate copper area for heat spreading, especially for high-current applications
- Use multiple vias under the module for improved thermal transfer to inner layers
- Consider thermal relief patterns for manufacturing while maintaining

Alternative Part Number

  • 750315371 --: Similar isolated DC-DC converter transformer in the same power class, widely available and pin-compatible in many designs.
  • PE-68386NL --: Isolated gate-drive/converter transformer with comparable turns ratio and isolation rating, suitable as a functional substitute.
  • B82801B --: Isolation transformer in a similar footprint and voltage class, usable when layout and isolation requirements are re-verified.
  • 78253/55MC --: Same 78253 series transformer with identical turns ratio and footprint, rated for the same isolation voltage; the MC variant is a direct drop-in with matching pinout and electrical specifications.
  • 78253/55JC --: Same series and core configuration as the original, offering equivalent inductance and isolation performance; suitable as a functional substitute where the VC suffix variant is unavailable.
  • 78253/55C --: Base 78253 series part with the same transformer construction and electrical ratings; provides a compatible alternative when the /55VC ordering code is not stocked.
  • DA2301-AL --: Isolated gate-drive transformer with comparable turns ratio and isolation performance, suitable as a functional substitute where layout can be adjusted.

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips