IC Phoenix logo

Home ›  5  › 54 > 598-8140-107F

598-8140-107F from DIALIGHT

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

598-8140-107F

Manufacturer: DIALIGHT

Micro LED SMD LED '598 SERIES' 0805 PACKAGE (2.0mm X 1.25mm X 0.7mm) Single Color

Partnumber Manufacturer Quantity Availability
598-8140-107F,5988140107F DIALIGHT 3000 In Stock

Description and Introduction

Micro LED SMD LED '598 SERIES' 0805 PACKAGE (2.0mm X 1.25mm X 0.7mm) Single Color The part 598-8140-107F is manufactured by DIALIGHT. It is a 24VAC/DC LED indicator light with a red lens. The specifications include:

- Voltage: 24VAC/DC
- Lens Color: Red
- Mounting Type: Panel Mount
- Light Source: LED
- Operating Temperature: -40°C to +75°C
- IP Rating: IP67 (dust-tight and protected against immersion in water up to 1 meter for 30 minutes)
- Dimensions: 22.5mm diameter
- Material: Polycarbonate lens, thermoplastic housing
- Certifications: UL, CSA, CE, RoHS compliant

This information is based on the factual specifications provided in Ic-phoenix technical data files.

Application Scenarios & Design Considerations

Micro LED SMD LED '598 SERIES' 0805 PACKAGE (2.0mm X 1.25mm X 0.7mm) Single Color # Technical Documentation: DIALIGHT 5988140107F LED Indicator

## 1. Application Scenarios

### Typical Use Cases
The DIALIGHT 598814-0107F is a high-performance LED indicator light designed for industrial and commercial applications requiring reliable visual status indication. This component features a bi-color (red/green) LED configuration with a compact 8mm mounting diameter, making it suitable for space-constrained applications.

 Primary Applications Include: 
-  Industrial Control Panels : Machine status indication (running/stopped/fault conditions)
-  Medical Equipment : Patient monitoring systems and diagnostic equipment status
-  Telecommunications : Network equipment status and fault indication
-  Transportation Systems : Vehicle control panel status lights
-  Building Automation : HVAC system status and alarm indicators

### Industry Applications
 Manufacturing & Automation 
- Production line status monitoring
- Equipment operational state indication
- Safety system status alerts
- Quality control system indicators

 Medical & Healthcare 
- Patient monitoring equipment
- Diagnostic device status
- Medical instrument operational states
- Emergency system indicators

 Telecommunications & IT 
- Server rack status lights
- Network switch indicators
- Data center equipment monitoring
- Communication system status

### Practical Advantages and Limitations

 Advantages: 
-  High Reliability : 100,000+ hour LED lifespan
-  Low Power Consumption : Typically 20mA per color at 2.1V forward voltage
-  Bright Visibility : High-intensity LEDs suitable for well-lit environments
-  Bi-Color Capability : Single component provides multiple status indications
-  Easy Installation : Snap-in panel mounting design
-  Wide Temperature Range : -40°C to +85°C operational range

 Limitations: 
-  Viewing Angle : Limited to approximately 60 degrees optimal visibility
-  Current Sensitivity : Requires precise current limiting for optimal performance
-  Environmental Constraints : Not suitable for direct sunlight or extreme UV exposure
-  Color Mixing : Limited to discrete red/green states without intermediate colors

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Insufficient Current Limiting 
-  Problem : Direct connection to voltage source without current regulation
-  Solution : Implement series resistors or constant current drivers
-  Calculation : R = (V_supply - V_f) / I_f (typically 150Ω for 5V supply)

 Pitfall 2: Incorrect Polarity for Bi-Color Operation 
-  Problem : Reverse polarity activation causing incorrect color display
-  Solution : Implement proper switching circuitry with reverse protection
-  Implementation : Use dedicated driver ICs or transistor switching networks

 Pitfall 3: Thermal Management Issues 
-  Problem : Excessive current leading to premature LED degradation
-  Solution : Maintain current below maximum rated 30mA per color
-  Thermal Design : Ensure adequate PCB copper area for heat dissipation

### Compatibility Issues with Other Components

 Microcontroller Interfaces 
-  Voltage Level Matching : Ensure compatibility between MCU output and LED driver requirements
-  Current Sourcing Capability : Verify MCU can source/sink sufficient current (typically 20mA)
-  PWM Compatibility : Supports PWM dimming with appropriate driver circuitry

 Power Supply Considerations 
-  Voltage Regulation : Requires stable DC supply with minimal ripple
-  Inrush Current : Implement soft-start circuits if switching multiple indicators simultaneously
-  Grounding : Ensure proper ground return paths to avoid noise interference

### PCB Layout Recommendations

 Component Placement 
- Maintain minimum 3mm clearance from other heat-generating components
- Position for optimal viewing angle relative to enclosure window
- Consider service access for potential replacement

 Routing Guidelines 
- Use 20-24 mil traces for LED power connections
- Implement star-point grounding for multiple indicators
- Route

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips