IC Phoenix logo

Home ›  5  › 54 > 598-8091-107F

598-8091-107F from DIALIGHT

Fast Delivery, Competitive Price @IC-phoenix

If you need more electronic components or better pricing, we welcome any inquiry.

598-8091-107F

Manufacturer: DIALIGHT

Micro LED SMD LED '598 SERIES' 0603 PACKAGE (1.6mm X 0.8mm X 0.7mm) Single Color

Partnumber Manufacturer Quantity Availability
598-8091-107F,5988091107F DIALIGHT 40000 In Stock

Description and Introduction

Micro LED SMD LED '598 SERIES' 0603 PACKAGE (1.6mm X 0.8mm X 0.7mm) Single Color The part 598-8091-107F is manufactured by DIALIGHT. It is a high-performance LED light fixture designed for industrial and hazardous locations. The specifications include:

- **Voltage**: 120-277V AC
- **Power Consumption**: 30W
- **Lumen Output**: 3,900 lumens
- **Color Temperature**: 5000K (Daylight)
- **CRI (Color Rendering Index)**: 70
- **Beam Angle**: 120 degrees
- **Housing Material**: Aluminum
- **Lens Material**: Polycarbonate
- **Ingress Protection**: IP66
- **Operating Temperature**: -40°C to 60°C (-40°F to 140°F)
- **Certifications**: UL 844 for Hazardous Locations, UL 1598 for Wet Locations, and CSA C22.2 No. 137

This fixture is suitable for use in environments requiring durable and reliable lighting, such as oil refineries, chemical plants, and other industrial settings.

Application Scenarios & Design Considerations

Micro LED SMD LED '598 SERIES' 0603 PACKAGE (1.6mm X 0.8mm X 0.7mm) Single Color # Technical Documentation: DIALIGHT 5988091107F LED Indicator Light

## 1. Application Scenarios

### Typical Use Cases
The DIALIGHT 5988091107F is a panel-mounted LED indicator light designed for industrial and commercial applications requiring clear visual status indication. Typical implementations include:

-  Equipment Status Monitoring : Power-on indicators, operational status lights, and fault warnings on industrial machinery
-  Control Panel Integration : User interface feedback on control panels, automation systems, and human-machine interfaces (HMI)
-  Safety Indication : Warning lights for hazardous conditions, emergency stop status, and safety system activation
-  Network Equipment : Status indicators for servers, routers, switches, and telecommunications equipment

### Industry Applications
-  Industrial Automation : PLC control panels, motor control centers, and process control systems
-  Transportation : Railway signaling, aircraft cockpit panels, and automotive dashboard indicators
-  Medical Equipment : Patient monitoring systems, diagnostic equipment status lights
-  Telecommunications : Network infrastructure status indicators and data center equipment
-  Energy Sector : Power distribution panels, renewable energy system monitoring

### Practical Advantages and Limitations

 Advantages: 
-  High Reliability : Solid-state LED technology provides >50,000 hours operational life
-  Low Power Consumption : Typically operates at 20mA with 2.1V forward voltage
-  Excellent Visibility : High-intensity LED with wide viewing angle (120° typical)
-  Environmental Resistance : IP67 rated for dust and water immersion protection
-  Easy Installation : Snap-in panel mounting with integrated retention springs

 Limitations: 
-  Temperature Sensitivity : Operating range limited to -40°C to +85°C
-  Voltage Requirements : Requires current-limiting resistor for proper operation
-  Panel Thickness : Compatible with 1-3mm panel thickness only
-  Color Specificity : Fixed LED color (verify specific color in datasheet)

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Incurrent Current Limiting 
-  Problem : Direct connection to voltage source without current limiting damages LED
-  Solution : Implement series resistor calculated using R = (V_supply - V_f) / I_f

 Pitfall 2: Inadequate Heat Management 
-  Problem : High ambient temperatures reduce LED lifespan
-  Solution : Ensure proper ventilation and derate current at elevated temperatures

 Pitfall 3: Poor Viewing Angle Alignment 
-  Problem : Indicator not visible from required viewing positions
-  Solution : Conduct viewing angle analysis during panel layout design

### Compatibility Issues

 Electrical Compatibility: 
- Requires compatible DC power supply (typically 5V, 12V, or 24V systems)
- Incompatible with AC power without additional rectification circuitry
- Ensure voltage regulator stability to prevent flickering

 Mechanical Compatibility: 
- Panel cutout requirement: 8mm circular hole
- Verify panel material compatibility with mounting mechanism
- Check clearance behind panel for LED depth (15.5mm)

 Optical Compatibility: 
- Consider ambient lighting conditions when selecting LED intensity
- Verify color recognition requirements for specific applications

### PCB Layout Recommendations

 Power Supply Considerations: 
- Place current-limiting resistor close to LED terminals
- Implement decoupling capacitor (100nF) near power connections
- Use adequate trace width for expected current (≥0.5mm for 20mA)

 Signal Integrity: 
- Route indicator lines away from high-frequency signals
- Implement ground plane for noise reduction
- Consider ESD protection for externally accessible indicators

 Mechanical Layout: 
- Allow sufficient clearance around mounting area (≥2mm)
- Ensure panel mounting doesn't stress PCB connections
- Consider service access for replacement

## 3. Technical Specifications

### Key Parameter Explanations

 Electrical Characteristics: 

Request Quotation

For immediate assistance, call us at +86 533 2716050 or email [email protected]

Part Number Quantity Target Price($USD) Email Contact Person
We offer highly competitive channel pricing. Get in touch for details.

Specializes in hard-to-find components chips