597-3311-407

Manufacturer: DIALIGHT

Surface Mount LED

Partnumber Manufacturer Quantity Availability
597-3311-407,5973311407 DIALIGHT 25000 In Stock

Description and Introduction

Surface Mount LED The part number 597-3311-407 is manufactured by DIALIGHT. It is a green LED indicator light designed for use in various industrial and commercial applications. The specifications for this part include:

- **Color:** Green
- **Voltage:** 24V DC
- **Lens Material:** Polycarbonate
- **Housing Material:** Thermoplastic
- **Mounting Type:** Panel Mount
- **IP Rating:** IP67 (Dust-tight and protected against immersion in water up to 1 meter for 30 minutes)
- **Operating Temperature Range:** -40°C to +85°C
- **Luminous Intensity:** Typically around 2000 mcd (millicandela)
- **Life Expectancy:** Approximately 100,000 hours

This indicator light is commonly used in control panels, machinery, and other equipment where a durable and reliable visual signal is required.

Application Scenarios & Design Considerations

Surface Mount LED # Technical Documentation: DIALIGHT 5973311407 LED Indicator Light

## 1. Application Scenarios

### Typical Use Cases
The DIALIGHT 5973311407 is a high-performance LED indicator light designed for industrial and commercial applications requiring reliable status indication. This component serves as a visual signaling device in various electronic systems, providing clear, energy-efficient illumination with long service life.

 Primary Applications Include: 
-  Industrial Control Panels : Status indication for machine operation, fault detection, and system readiness
-  Power Distribution Systems : Visual feedback for circuit breaker status, power availability, and system alerts
-  Telecommunications Equipment : Network status monitoring and equipment operational indicators
-  Medical Devices : Patient monitoring equipment status and system operational indicators
-  Transportation Systems : Vehicle control panel indicators and infrastructure status monitoring

### Industry Applications
 Manufacturing & Automation 
- Machine tool status indicators
- Production line monitoring systems
- Robotics control panel indicators
- Safety system status lights

 Energy & Infrastructure 
- Power substation control panels
- Renewable energy system monitors
- Building management systems
- Emergency power supply indicators

 Transportation 
- Railway signaling systems
- Aircraft cockpit indicators
- Automotive dashboard lights
- Marine navigation equipment

### Practical Advantages and Limitations

 Advantages: 
-  High Efficiency : Low power consumption with excellent luminous intensity
-  Long Lifespan : Typically exceeds 50,000 hours of continuous operation
-  Robust Construction : Designed to withstand industrial environments
-  Easy Installation : Standard mounting configuration with simple wiring requirements
-  Wide Operating Temperature : Performs reliably in extreme environmental conditions
-  Consistent Performance : Stable light output throughout operational lifespan

 Limitations: 
-  Viewing Angle Constraints : Optimal visibility within specified angular range
-  Environmental Sensitivity : Performance may degrade in extremely high humidity conditions
-  Heat Management : Requires proper thermal considerations in high-density installations
-  Compatibility : Specific voltage requirements must be matched with driving circuitry

## 2. Design Considerations

### Common Design Pitfalls and Solutions

 Pitfall 1: Inadequate Current Limiting 
-  Problem : Direct connection to power source without proper current regulation
-  Solution : Implement constant current drivers or appropriate series resistors
-  Recommendation : Use calculated current limiting resistors based on forward voltage specifications

 Pitfall 2: Poor Thermal Management 
-  Problem : Overheating due to insufficient heat dissipation
-  Solution : Ensure adequate spacing and consider heat sinking in high-density layouts
-  Recommendation : Maintain minimum 5mm clearance between adjacent indicators

 Pitfall 3: Incorrect Voltage Matching 
-  Problem : Mismatch between LED forward voltage and supply voltage
-  Solution : Verify voltage compatibility and use appropriate driving circuits
-  Recommendation : Implement voltage regulation circuits for stable operation

### Compatibility Issues with Other Components

 Electrical Compatibility 
-  Microcontrollers : Compatible with 3.3V and 5V logic levels
-  Power Supplies : Requires stable DC power source with minimal ripple
-  Switching Circuits : Works well with transistor drivers and relay interfaces

 Mechanical Compatibility 
-  Panel Mounting : Standard 8mm mounting hole requirement
-  Connector Systems : Compatible with standard 2-pin connectors
-  Enclosure Design : Requires proper sealing for IP-rated applications

 Optical Compatibility 
-  Light Sensors : May interfere with adjacent optical sensors if not properly shielded
-  Display Panels : Consider ambient light conditions for optimal visibility

### PCB Layout Recommendations

 General Layout Guidelines 
-  Placement : Position for optimal viewing angle and accessibility
-  Routing : Keep LED driver circuits close to the indicator
-  Grounding : Implement proper ground planes for noise reduction

 Specific Recommendations 
```
1. Maintain minimum trace width: 0.

Request Quotation