IC Phoenix
 
Home ›  FF2 > FAN1851AMX,Ground Fault Interrupter
FAN1851AMX Fast Delivery,Good Price
Part Number:
If you need More Quantity or Better Price,Welcom Any inquiry.
We available via phone +865332716050 Email
Partno Mfg Dc Qty AvailableDescript
FAN1851AMXFAIN/a2377avaiGround Fault Interrupter


FAN1851AMX ,Ground Fault InterrupterFeatures Description• Improved performance over industry equivalents The FAN1851A is a controller f ..
FAN1950D25X ,1.5A Low Voltage LDOGeneral Description• 1.5A minimum guaranteed output current The FAN1950 and FAN1951 are 1.5A low-dr ..
FAN1951D25X ,1.5A Low Voltage LDOfeatures to ensure full protection. •Fast transient response•Low ground current The FAN1951 offers ..
FAN1951D25X ,1.5A Low Voltage LDO FAN1950/FAN19511.5A Low-Voltage Low-Dropout Regulator
FAN2001 ,High-efficiency step-down DC/DC converterApplicationSWVVOUTIN161.2V (1A)FB EN3.3µH1C 6INPGND10KΩ P1C R22 5NC 5KΩR1 OUT PGND V P1(AGN ..
FAN2011MPX ,High-efficiency step-down DC/DC converterfeatures include input under-voltage lockout, short■ Point of Load Powercircuit protection and ther ..
FHP3131IS6X , 0.4mA, 2.5V to 12V, 70MHz Rail-to-Rail Amplifier
FHP3230IMU8X , Single, Dual, and Quad, High Speed, 2.7V to 12V, Rail-to-Rail Amplifiers
FHP3230IMU8X , Single, Dual, and Quad, High Speed, 2.7V to 12V, Rail-to-Rail Amplifiers
FHP3430IMTC14X , Single, Dual, and Quad, High Speed, 2.7V to 12V, Rail-to-Rail Amplifiers
FHP3430IMTC14X , Single, Dual, and Quad, High Speed, 2.7V to 12V, Rail-to-Rail Amplifiers
FHP3450IM14X , Triple and Quad Voltage Feedback Amplifiers


FAN1851AMX
Ground Fault Interrupter

Features
Improved performance over industry equivalents
– Tight fault current range (Typ ±100µA)
– Temperature compensated fault current characteristics
– No external trimming required Direct interface to SCR Supply voltage derived from AC line—26V shunt Adjustable sensitivity Grounded neutral fault detection Meets UL943 standards 450µA quiescent current Ideal for 120V or 220V systems Package options: 8L DIP and 8L SOIC
Description

The FAN1851A is a controller for AC outlet ground fault
interrupters. These devices detect hazardous grounding con-
ditions (example: a pool of water or an electrical equipment
connected to opposite phases of the AC line) in consumer
and industrial environments. The output of the IC triggers an
external SCR, which in turn opens a relay circuit breaker to
prevent a harmful or lethal shock.
Full advantage of the U.S. UL943 timing specification is
taken to ensure maximum immunity to false triggering due
to line noise. A special feature in the circuitry rapidly resets
the integrating timing capacitor in the event that noise pulses
introduce unwanted charging currents. Also, a flip-flop is
included that ensures firing of even a slow circuit breaker
relay on either of the two half-cycles of the line voltage
when external full wave rectification is used.
The application circuit can be configured to detect both
normal faults (hot wire to ground) and grounded neutral
faults.
ic,good price